Kalpna Tiwari

Kalpna Tiwari

Auto-generated profile, based on publicly available information

Kalpna Tiwari

University of Delhi

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2026 in Semiconductor Science and Technology
Verified
Journal Article
Closed access
KTKalpna Tiwari
Kalpna Tiwari
CJChakresh Jain
Chakresh Jain
MSManvinder Pal Singh
Manvinder Pal Singh
NNNishu Nishu
Nishu Nishu
NANamrata Agrawal
Namrata Agrawal
KRKirti Ranjan
Kirti Ranjan
Low gain avalanche detectors (LGADs) are poised for deployment in the intense radiation environments of future particle physics experiments. These advanced silicon sensors incorporate an additional moderately doped p + layer (in p-type substrate having n + as the high doping layer) to create a high electric field region, facilitating impact ionisation. This design imparts LGADs with superior timing capabilities, high signal-to-noise ratio, and radiation hardness compared to traditional silicon sensors. Given their application in particle colliders where they are exposed to high levels of charged and neutral hadrons, understanding LGAD behaviour under such conditions is critical to optimise their performance. In this study, we use the Silvaco technology computer-aided design simulation platform to evaluate the performance of neutron-irradiated LGADs against the available measurement results. The simulations incorporate the neutron radiation damage model, previously developed at the University of Delhi for traditional silicon sensors. However, LGADs also exhibit an acceptor removal mechanism, particularly in the gain layer, which is not accounted for in the existing model. Further, a distinctive feature of the LGAD is the importance of charge multiplication or impact ionisation even at small bias voltages. There is a need to optimise the impact-ionisation parameters, both for non-irradiated and neutron-irradiated LGADs. To address this, the present neutron radiation damage model is extended for thick (300 µ m) neutron-irradiated LGAD structures, where the acceptor removal mechanism and optimised impact ionisation model are integrated in the simulation framework. By exploiting the results, these LGAD parameters are optimised to successfully reproduce and explain experimental data for thick LGADs, full depletion voltage ( V FD ) and charge collection (CC). This validation of our model is crucial for optimising radiation-hard LGAD designs, essential for mitigating increased dark current and decreased CC efficiency in high-neutron-fluence environments.

1 August 2026 in Semiconductor Science and Technology
Verified
Journal Article
Closed access
RGRajiv Gupta
Rajiv Gupta
SSSunidhi Saxena
Sunidhi Saxena
CJChakresh Jain
Chakresh Jain
KTKalpna Tiwari
Kalpna Tiwari
NANamrata Agrawal
Namrata Agrawal
AKAjay Kumar
Ajay Kumar
We present comprehensive technology computer-aided design modeling results for a proton-irradiated, 300 μ m thick low gain avalanche detector (LGAD) with a boron implant dose of 1.6 × 10 13 cm − 2 . We first assess the geometrical and doping parameters of the simulated LGAD through comparison of the electrical and transient current technique characteristics with experimental measurements. Subsequently, we model the effects of proton irradiation on the simulated device. Unlike traditional detectors (PIN and strip detectors), LGADs contain an additional gain layer that facilitates intrinsic charge multiplication but undergoes acceptor removal under irradiation, necessitating the incorporation of these effects in radiation-damage modeling. We employ the Delhi University’s Proton Damage Model (PDM), originally developed for traditional sensors, as a baseline to incorporate radiation-induced trap defects. We then extend the PDM by implementing the acceptor removal mechanism (ARM) to account for the acceptor removal in the gain layer. The simulation results, incorporating the combined PDM and ARM framework, still underestimate the experimental gain, indicating that the model requires further advancements to capture the real device behavior. To understand this discrepancy, we investigate the role of impact ionization in charge multiplication. While the default Selberherr impact ionization model effectively estimated the gain for a non-irradiated LGAD, reproducing the gain of the irradiated LGAD required a fluence-dependent parameterization. This parameterization led to reasonable agreement between the simulated gain and the corresponding gain measurements under red and IR laser illumination. Further, we examine the electrical characteristics of the irradiated device using both the default and the optimized Selberherr impact ionization models to assess the impact of the parameterization. Overall, this work provides comprehensive insights into proton-induced damage in LGADs and highlights the need for refined modeling approaches.