Amir Aghazadeh

Amir Aghazadeh

Auto-generated profile, based on publicly available information

Amir Aghazadeh

School of Electronic and Electrical Engineering, University of Leeds, Leeds, U.K.

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
AAAmir Aghazadeh
Amir Aghazadeh
MDMasoud Davari
Masoud Davari
HNHamed Nafisi
Hamed Nafisi
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg

15 November 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
AAAmir Aghazadeh
Amir Aghazadeh
MJMohamadsaleh Jafari
Mohamadsaleh Jafari
NKNaser Khodabakhshi-Javinani
Naser Khodabakhshi-Javinani
HNHamed Nafisi
Hamed Nafisi
HNHamed Jabbari Namvar
Hamed Jabbari Namvar
In this paper, Space Opposite Vectors Modulation (SOVM) is proposed to decrease Common-Mode Voltage (CMV), and also improve inverter switching losses compared to PWM7 for Dual Two-Level Inverters (DTLI). Employing the control simplicity of DTLI to achieve multi-level winding voltages, the two conventional two-level inverters of DTLI are independently controlled; consequently, the capability of adjusting Phase Difference between the Carriers (PDC) of two inverters is established. To mathematically evaluate and compare the performance of DTLI driven by SOVM and PWM7, CMV and losses for different PWMs are formulated. Moreover, contour, 3-D and 2-D analyses are conducted to investigate the effects of PDC and Modulation Index (MI) on CMV, voltage Total Harmonic Distortion (THD), voltage Weighted Total Harmonic Distortion (WTHD) and switching losses. All theoretical bases, simulation results from MATLAB/Simulink and experimental results conducted by a DTLI prototype validate the superiority of SOVM over PWM7.

11 February 2019 in IET Power Electronics
Verified
Journal Article
Open access
PDF file
AAAmir Aghazadeh
Amir Aghazadeh
NKNaser Khodabakhshi‐Javinani
Naser Khodabakhshi‐Javinani
HNHamed Nafisi
Hamed Nafisi
MDMasoud Davari
Masoud Davari
EPEdris Pouresmaeil
Edris Pouresmaeil
In this paper, a near‐state pulse‐width modulation (NSPWM) algorithm is proposed and implemented on dual‐two‐level voltage‐source inverters (D2L‐VSIs) in order to reduce the common‐mode voltage (CMV), the inverter switching losses, the current total harmonic distortion, and the side effects of bearing currents ‐‐compared with space vector modulation (SVM) and PWM7. To gain these goals, two conventional two‐level inverters of the D2L‐VSI are controlled, separately, with specific switching sequences and an adjusted phase difference between the carriers of two inverters. For evaluating and comparing these PWM techniques mathematically, both CMV root mean square generated and switching losses of the D2L‐VSI are formulated as a function of the power factor of the D2L‐VSI, which is driven by the methods detailed in this study. Eventually, theories and analysis, as well as simulations and experimental results ‐‐which are generated by MATLAB/Simulink environment and a 300 W scaled‐down D2LVSI prototype, respectively ‐‐authenticate the superiority of the proposed NSPWM over both SVM and PWM7.

22 March 2024 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
MDMasoud Davari
Masoud Davari
Weinan GaoWeinan Gao
Weinan Gao
AAAmir Aghazadeh
Amir Aghazadeh
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
FLFrank L. Lewis
Frank L. Lewis
When it comes to integrating inverter-based resources (IBRs) into modern grids with varying characteristics like unbalanced systems, low-inertia networks, or very weak grids, synthesizing the synchronization control method (SCM) of the IBR’s phase-locked loop can be a challenging task. This paper provides a unique solution to enhance the three-phase IBR’s SCM using the adaptive dynamic programming (ADP) method based on reinforcement learning. By making the SCM more intelligent and self-learning, IBRs can be easily integrated into diverse grids. To this end, this article investigates the synchronization process’s detailed dynamics, including all incorporating disturbances and parameters required for the first step in designing the ADP method. Afterward, this research synthesizes an optimal controller using an ADP method. It is a data-driven and practically sound approach to the problem under investigation. The new methodology is based on the adaptive optimal control employing measurement feedback to control the output regulation problem of uncertain synchronization process dynamics via the internal model principle. The proposed SCM design deploys an ADP learning methodology to tackle uncertain parameters and unknown disturbance signals to synchronize IBRs during transients, thereby enhancing IBRs’ synchronization in challenging conditions of modern power systems with unbalanced, low-inertia, and very weak grids. For comparison purposes, this paper applies a robust controller based on the well-established $\mu$ synthesis approach (benefiting from the well-known $D\text{-}K$ iteration process). Comparative simulations are performed; experiments are conducted to reveal the effectiveness and practicality of the ADP-based optimal SCM proposed in this paper. Note to Practitioners —As different nations strive to combat global warming and accelerate decarbonization, power and energy systems are undergoing a significant shift. Inverter-based resources are being used as an essential component to achieve these goals. However, studies have revealed that designing synchronization control methods of the inverter-based resources’ phase-locked loop in unbalanced, low-inertia, and very weak grids is challenging due to the need for accurate dynamic models and other factors. This study revisits the synchronization process’s detailed dynamics. It also proposes a novel adaptive dynamic programming strategy using intelligent self-learning approaches to the synchronization control method associated with inverter-based resources. This method utilizes an optimal control to synthesize the adaptive dynamic programming control strategy for the inverter-based resources’ synchronization process. Besides, it employs measurement feedback to control the output regulation problem of uncertain dynamics of inverter-based resources’ synchronization process via the internal model principle. As a result, this paper makes this process data-driven. It utilizes a learning methodology using adaptive dynamic programming to address uncertain parameters and unknown disturbance signals associated with the dynamics derived and formulated for the problem under investigation. Thus, the proposed method applies to controlling inverter-based resources’ synchronization process even in cases with slow parameter variations caused by different factors. It can compensate for all functional disturbance signals affecting the dynamics of the systems. In fact, unlike traditional methods that need an exact dynamic model of the inverter-based resources’ synchronization process to design and tune the controller to achieve a proper transient response, the proposed control system trains itself and does so. This study’s simulations and experiments reveal that the above points give the proposed approach a competitive edge over the existing methodologies.

6 November 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
MDMasoud Davari
Masoud Davari
AAAmir Aghazadeh
Amir Aghazadeh
WGWeinan Gao
Weinan Gao
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
Nowadays, emerging microgrids have been forming fully integrated power and energy systems using multi-infeed ac/dc (MIACDC) power architectures. An MIACDC power architecture easily integrates renewables, battery energy storage systems, fossil-fuel-based generating units, and various types of loads into one coherent microgrid. Therefore, in modernized microgrids (MMGs), time constants (or equivalently bandwidths) of system dynamics are broad; indeed, multiple controls in different parts of grid-connected voltage-sourced converters (GC-VSCs) create them. For the first time, this paper takes into account the detailed dynamics of every GC-VSC’s parts. It also effectively incorporates their controls to propose “detailed” dynamic dc (DDDC) models for dc-fault simulations. The suggested models are able to simulate dc-fault currents in MMGs’ MIACDC power systems more accurately. This research bridges the gap between VSCs’ controls and their dynamic dc models, which can be used in dc-fault simulation studies associated with the MMG protection. It derives DDDC models of GC-VSCs for two fundamental modes of operation, i.e., P/Q-controlled and VDC/Q-controlled modes. To this end, detailed dynamics of VSCs considering those of ac- and dc-side filters have thoroughly been employed using VSCs’ space-phasor representation. After linearization, for creating the models mentioned above, relevant GC-VSCs’ controls have been considered. In order to show the validity of the detailed GC-VSC’s dynamic dc models, experimental results have been provided. Besides, for studying the models’ response to dc faults, adequate comparisons of time-domain simulations of the proposed models and those of the accurate switching models have been made. In this regard, an MMG with the MIACDC structure has been simulated in PSCAD™/EMTDC™ software; the MMG has been implemented first by the proposed VSC’s DDDC models and second by the switching ones to generate the simulation results with which one can compare. Moreover, in order to reveal the effectiveness of the DDDC models, comparative outputs are produced by simulating conventional models that do not consider dynamics induced by the controllers. Last but not least, comparison outcomes of the DDDC models and those of conventionally adopted models show that this research is able to fill in gaps in the needed models.

8 April 2024 in IEEE Access
Verified
Journal Article
Open access
AAAmir Aghazadeh
Amir Aghazadeh
EHEhsan Hajipour
Ehsan Hajipour
Kang LiKang Li
Kang Li
SASadegh Azizi
Sadegh Azizi
Inrush current is high-magnitude current drawn by power transformers upon energization. The severity of inrush current depends on factors such as the transformer’s residual flux and the voltage phase angle at the energization instant. This paper proposes a flux matching method for the energization of V/V traction transformers to mitigate inrush current. This is achieved by adjusting the residual flux of the core to an appropriate reference value and then obtaining the proper energization instant. To this end, the method only requires knowledge of nominal voltage and excitation current, eliminating the need to acquire transformer’s parameters/design information. The railway power conditioner, typically present at the low voltage side of the V/V transformer, is used as a current source to inject sinusoidal current into the transformer windings before its energization. The reference residual flux is calculated based on the circuit breaker operating characteristics. The energization instant is determined such that the adjusted flux density matches the steady-state flux expected with respect to the applied voltage. The proposed method is validated by conducting over 14,000 simulations under different conditions using PSCAD/EMTDC. The method is also implemented and successfully tested on a laboratory-scale test rig, which verifies its effectiveness in more realistic conditions.