1 September 2022 in Plasma Sources Science and Technology
A plasma loss to sidewall model is used for one-dimensional (1D) particle-in-cell (PIC) with Monte Carlo collision (MCC) simulation to calculate plasma transport through a transverse magnetic field in a negative ion source chamber. The presented 1D model includes plasma radial loss treatment when calculating the plasma transport in the axial direction. It does not cost computation effort as much as a 2D or 3D model and can be used to estimate the plasma transport process quickly. The conventional 1D kinetic model calculates particle motion only in the ‘x’-direction. The sidewall loss in the ‘y’ ‘z’ direction is not included, leading to unusual plasma distribution. Especially when applying a transverse magnetic field, the motion and loss of electrons along the magnetic field line to the sidewall are ignored. Thus electrons are completely constrained by the magnetic field, resulting in abnormal plasma density accumulation. The sidewall loss estimation method uses Bohm velocity calculated from plasma parameters as radial loss velocity to obtain the plasma flux to the sidewall. And the sidewall loss rate can be obtained from the flux combined with chamber geometry. This method is integrated into a self-developed 1D PIC–MCC program to examine its effect. Several verification cases are performed separately for the PIC, MCC, and the sidewall loss treatment module, and the results exhibit good reliability. Simulations are then carried out to study plasma transport across the magnetic field under similar conditions to actual experiments. Simulation results agree with the experiment, which indicates that the 1D sidewall loss model is useful when dealing with plasma transport in the source chamber.
6 October 2022 in Frontiers in Immunology
Hepatitis B virus (HBV)-infected hepatocellular carcinoma (HCC) has a high incidence and fatality rate worldwide, being among the most prevalent cancers. The growing body of data indicating cellular senescence (CS) to be a critical factor in hepatocarcinogenesis. The predictive value of CS in HBV-related HCC and its role in the immune microenvironment are unknown. To determine the cellular senescence profile of HBV-related HCC and its role in shaping the immune microenvironment, this study employed a rigorous evaluation of multiple datasets encompassing 793 HBV-related HCC samples. Two novel distinct CS subtypes were first identified by nonnegative matrix factorization, and we found that the senescence-activated subgroup had the worst prognosis and correlated with cancer progression. C1 and C2 were identified as the senescence-suppressed and senescence-activated subgroups. The immune microenvironment indicated that C2 exhibited a relatively low immune status, higher tumor purity, and lower immune scores and estimated scores, while the C1 subgroup possessed a better prognosis. The CS score signature based on five genes (CENPA, EZH2, G6PD, HDAC1, and PRPF19) was established using univariate Cox regression and the lasso method. ICGC-LIRI and GSE14520 cohorts were used to validate the reliability of the CS scoring system. In addition, we examined the association between the risk score and hallmark pathways through gene set variation analysis and gene set enrichment analysis. The results revealed a high CS score to be associated with the activation of cell senescence-related pathways. The CS score and other clinical features were combined to generate a CS dynamic nomogram with a better predictive capacity for OS at 1, 2, and 3 years than other clinical parameters. Our study demonstrated that cellular senescence patterns play a non-negligible role in shaping the characteristics of the immune microenvironment and profoundly affecting tumor prognosis. The results of this study will help predict patient prognosis more accurately and may assist in development of personalized immunotherapy for HBV-related HCC patients.
28 December 2018 in AIP Conference Proceedings
Faraday shield (FS), a thin-wall metal structure with slits, is used in inductive coupled plasma (ICP) sources to protect the ceramic tube from plasma erosion and eliminate capacitive coupling. Electromagnetic energy is coupled into the driver through the slits, which makes FS an important component of ICP sources. Material and structure, which are critical for FS, should have effects on the distribution of electromagnetic field and temperature. In this contribution, discussions on various materials and structures’ impact on electromagnetic and thermal performance arise. FS made of copper, aluminum, molybdenum and stainless steel, as well as FS of different thickness, slit width, slit numbers and slit shapes, are investigated by numerical simulations referring to the parameters of an actual ICP source. Electromagnetic field, RF power loss, temperature and stress of different FS are compared. The results show that Mo has similar electromagnetic performance with Cu but better thermal performance than Cu for FS. As for structure, RF power transfer efficiency decreases slightly as FS thickens. Appropriate slit width and number are required to allow a sufficient RF coupling and acceptable plasma heat flux to ceramic tube. RF efficiency of z-shaped slotted FS and normally slotted FS is almost the same.
23 September 2022 in Plasma Physics and Controlled Fusion
The prototype for a negative hydrogen ion source for neutral beam injection of China Fusion Engineering Test Reactor is being developed at the Southwest Institute of Physics. To study the physics of negative ion beam transport and to optimize the design of the source, the stripping loss and the stray particles’ impacts on the one-RF-driver prototype are analyzed. Collision simulation, including both the beam-gas collisions and the particle-grid collisions, is carried out basing on the results of gas flow evaluation and particle tracing. The stripping loss, the distribution of stray particles and the heat loads are calculated, comparing two configurations of grounded grid (GG) (multiaperture or multislot). At the source filling pressure of 0.3 Pa and the vessel pressure 0.05 Pa, the extraction voltage being 8 kV and the acceleration voltage 200 kV and the extraction grid (EG) magnet peak of ±45 mT, the stripping loss of the 200 A m−2 H− beam can be reduced from 25% to 20% by changing GG from multiapertures to multislots. The H− proportion in the total current at 40 mm after GG, however, shows smaller change than the reduction of the stripping loss possibly because the multislot GG’s larger transparency increases the chance for the stray particles to pass through GG. The total heat load on EG in the two cases with different GG configurations are both around 66 kW, while the GG heat load is reduced from 45 kW for multiapertures to 17 kW for multislots. The study provides good comprehension of the transport process and useful guidance for practical operations.
12 December 2022 in Fusion Engineering and Design
1 August 2023 in Plasma Physics and Controlled Fusion
A radio-frequency driven negative hydrogen ion source is under development at Huazhong University of Science and Technology, which aims to investigate the physics of production and extraction of negative ions. The source operational parameters are investigated to investigate the source plasma characteristics and to optimize the extraction properties before cesium injection, which means, in this study, that negative ions were mostly produced by reactions in the plasma volume. The magnetic filter field generated by a plasma grid (PG) current flowing through the PG can cool down the electron temperature below 1 eV, but simultaneously increased the plasma density in the extraction region. The plasma asymmetry in the direction perpendicular to the PG filter field, is discussed and compared with that in other ion sources. As the PG current increased, the asymmetry factors tended to increase first and then decrease. Biasing the PG positively with respect to the source body can reduce the co-extracted electrons effectively, resulting in reducing the electron to H− ion current ratio. An extracted negative beam with a current density of about 19 A m−2 and an energy of 12 keV was achieved under 20 kW RF power and 0.3 Pa filling pressure, with a ratio of electron current to ion current of about 54.