Chunjiao Dong

Chunjiao Dong

Auto-generated profile, based on publicly available information

Chunjiao Dong

Department of Medical Imaging, Hebei Medical University, 050031 Shijiazhuang, Hebei, China; Department of Electrical Engineering, Eindhoven University of Technology, 5612 AP Eindhoven, Netherlands

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2021 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
CDChunjiao Dong
Chunjiao Dong
YQYixian Qiao
Yixian Qiao
CSChunheng Shang
Chunheng Shang
XLXiwen Liao
Xiwen Liao
XYXiaoning Yuan
Xiaoning Yuan
YBYurong Bao
Yurong Bao

11 May 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CDChunjiao Dong
Chunjiao Dong
TYTianchun Ye
Tianchun Ye
XLXi Long
Xi Long
Ronald M. AartsRonald M. Aarts
Ronald M. Aarts
Johannes Van DijkJohannes Van Dijk
Johannes Van Dijk
YWYunfeng Wang
Yunfeng Wang
Using monitoring devices could help avoid injuries and even death. Currently, wearable sensors such as motion sensors and other sensors are used to detect when the patient is having a seizure and alarm their caregivers. However, the development phase of these devices requires labor-intensive work on labeling the collected data, resulting in difficulties in developing wearable monitoring devices. Thus, a more automated auxiliary method of labeling seizure data and a wearable device to detect seizures for daily monitoring use are necessary. We collected data from epileptics outside the hospital with our proposed bracelet. The subjects were asked to press the mark button after they had seizures. We also presented an automatically extraction and annotation of moving segments (EAMS) algorithm to exclude nonmoving segments. Then, we used a two-layer ensemble model (TLEM) using machine learning methods to classify seizures and non-seizure moving segments, which was designed to deal with imbalanced dataset. Then, we build two individual TLEM models separately for the overall (all day and night) seizure detection case and the night seizure detection case, owing to different imbalance of these datasets. The EAMS algorithm exclude 93.9% raw inactive data. The TLEM model achieved 76.84% sensitivity (SEN) and 97.28% accuracy (ACU) for the overall case and achieved 94.57% SEN and 91.37% ACU for the night case. These results indicate that this bracelet can capture seizures efficiently, and our proposed TLEM has higher SEN and ACU than single-layer machine learning models.

29 September 2025 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
CDChunjiao Dong
Chunjiao Dong
JDJohannes P. van Dijk
Johannes P. van Dijk
RARonald M. Aarts
Ronald M. Aarts
YWYunfeng Wang
Yunfeng Wang
XLXi Long
Xi Long
Epileptic seizures can lead to severe outcomes including sudden unexpected death in epilepsy (SUDEP). Clinical standard for seizure diagnosis and detection requires electroencephalography and video monitoring, which is yet considered not suitable for home use, especially during nighttime sleep in a low-light condition. We proposed a deep learning (DL)-based approach to automatically detect nocturnal major seizures using a wearable armband that can potentially help reduce SUDEP risk through timely caregiver intervention. In this prospective cohort study, 68 patients with major seizures were monitored for up to three months using a wearable armband (NightWatch®) capturing tri-axial accelerometry (ACM) and photoplethysmography (PPG) signals. A two-step approach was designed: (1) a pre-screening step using threshold-based algorithms to identify suspected seizure events (ACM standard deviation >0.4 or heart rate increase >10%), and (2) a DL model (CNN-LSTM with attention mechanism) to recognize true seizures. Model performance was evaluated via a 10-fold cross-validation, reporting sensitivity (SEN), false alarm rate (FAR), and area under the ROC curve (AUC). In 788 overnight recordings (6304 hours), a total of 1846 severe seizures were identified. The pre-screening step achieved 0.940 sensitivity in pre-identifying or 'preserving' seizures, reducing data volume by 81% (from 6304 to 1201 hours). The DL model demonstrated a mean accuracy of 0.793 [95% CI: 0.745-0.841], a mean sensitivity of 0.762 [95% CI: 0.704-0.821], a mean positive predictive value of 0.334 [95% CI: 0.229-0.356] and a mean false alarm rate of 0.165/hour [95% CI: 0.097-0.234]. These results exceeded those of single (signal) modality detection methods. Our two-step approach enables accurate, long-term detection of severe nocturnal seizures in home settings. The wearable system provides a practical solution for continuous monitoring and real-time alerts, thus potentially reducing SUDEP risk and improving patient safety, fulfilling an urgent unmet need in epilepsy care. Furthermore, by enabling long-term home monitoring, this system may help assess the relationship between seizure events and lifestyle-related triggers such as sleep deprivation, stress, physical exertion, or alcohol consumption, thereby supporting the development of personalized preventive strategies.