Alexander Trumpp

Alexander Trumpp

Auto-generated profile, based on publicly available information

Alexander Trumpp

TU Dresden, Institute of Biomedical Engineering, Helmholtzstraße 18, Dresden, 01069 Saxony, Germany

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2018 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Open access
PDF file
SZSebastian Zaunseder
Sebastian Zaunseder
ATAlexander Trumpp
Alexander Trumpp
DWDaniel Wedekind
Daniel Wedekind
HMHagen Malberg
Hagen Malberg
Over the last few years, the contactless acquisition of cardiovascular parameters using cameras has gained immense attention. The technique provides an optical means to acquire cardiovascular information in a very convenient way. This review provides an overview on the technique’s background and current realizations. Besides giving detailed information on the most widespread application of the technique, namely the contactless acquisition of heart rate, we outline further concepts and we critically discuss the current state.

4 November 2016 in Clinical Hemorheology and Microcirculation
Verified
Journal Article
Closed access
SRS. Rasche
S. Rasche
ATA. Trumpp
A. Trumpp
TWT. Waldow
T. Waldow
FGF. Gaetjen
F. Gaetjen
KPK. Plötze
K. Plötze
SZS. Zaunseder
S. Zaunseder
Camera-based photoplethysmography (cbPPG) is an optical measurement technique that reveals pulsatile blood flow in cutaneous microcirculation from a distance. cbPPG has been shown to reflect pivotal haemodynamic events like cardiac ejection in healthy subjects. In addition, it provides valuable insight into intrinsic microcirculatory regulation as it yields dynamic, two-dimensional perfusion maps. In this study, we evaluate the feasibility of a clinical cbPPG application in critical care patients. A mobile camera set-up to record faces of patients at the bed site was constructed. Videos were made during the immediate recovery after cardiac surgery under standard critical care conditions and were processed offline. Major motion artefacts were detected using an optical flow technique and suitable facial regions were manually annotated. cbPPG signals were highpass filtered and Fourier spectra out of consecutive 10s signal segments calculated for heart rate detection. Signal-to-noise ratios (SNR) of the Fourier spectra were derived as a quality measure. Reference data of vital parameters were synchronously acquired from the bed site monitoring system. Seventy patient videos of an average time of 28.6±2.8 min were analysed. Heart rate (HR) was detected within a±5 bpm range compared to reference in 83% of total recording time. Low SNR and HR detection failure were mostly, but not exclusively, attributed to non-physiological events like patient motion, interventions or sudden changes of illumination. SNR was reduced by low arterial blood pressure, whereas no impact of other perioperative or disease-related parameters was identified. Cardiac ejection is detectable by cbPPG under pathophysiologic conditions of cardiovascular disease and perioperative medicine. cbPPG measurements can be seamlessly integrated into the clinical work flow of critical care patients.

14 March 2018 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
ATAlexander Trumpp
Alexander Trumpp
JLJohannes Lohr
Johannes Lohr
DWDaniel Wedekind
Daniel Wedekind
MSMartin Schmidt
Martin Schmidt
MBMatthias Burghardt
Matthias Burghardt
SZSebastian Zaunseder
Sebastian Zaunseder
Camera-based photoplethysmography (cbPPG) is a measurement technique which enables remote vital sign monitoring by using cameras. To obtain valid plethysmograms, proper regions of interest (ROIs) have to be selected in the video data. Most automated selection methods rely on specific spatial or temporal features limiting a broader application. In this work, we present a new method which overcomes those drawbacks and, therefore, allows cbPPG to be applied in an intraoperative environment. We recorded 41 patients during surgery using an RGB and a near-infrared (NIR) camera. A Bayesian skin classifier was employed to detect suitable regions, and a level set segmentation approach to define and track ROIs based on spatial homogeneity. The results show stable and homogeneously illuminated ROIs. We further evaluated their quality with regards to extracted cbPPG signals. The green channel provided the best results where heart rates could be correctly estimated in 95.6% of cases. The NIR channel yielded the highest contribution in compensating false estimations. The proposed method proved that cbPPG is applicable in intraoperative environments. It can be easily transferred to other settings regardless of which body site is considered.

1 March 2017 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
DWDaniel Wedekind
Daniel Wedekind
ATAlexander Trumpp
Alexander Trumpp
FGFrederik Gaetjen
Frederik Gaetjen
SRStefan Rasche
Stefan Rasche
KMKlaus Matschke
Klaus Matschke
SZSebastian Zaunseder
Sebastian Zaunseder
Blind source separation (BSS) aims at separating useful signal content from distortions. In the contactless acquisition of vital signs by means of the camera-based photoplethysmogram (cbPPG), BSS has evolved the most widely used approach to extract the cardiac pulse. Despite its frequent application, there is no consensus about the optimal usage of BSS and its general benefit. This contribution investigates the performance of BSS to enhance the cardiac pulse from cbPPGs in dependency to varying input data characteristics. The BSS input conditions are controlled by an automated spatial preselection routine of regions of interest. Input data of different characteristics (wavelength, dominant frequency, and signal quality) from 18 postoperative cardiovascular patients are processed with standard BSS techniques, namely principal component analysis (PCA) and independent component analysis (ICA). The effect of BSS is assessed by the spectral signal-to-noise ratio (SNR) of the cardiac pulse. The preselection of cbPPGs, appears beneficial providing higher SNR compared to standard cbPPGs. Both, PCA and ICA yielded better outcomes by using monochrome inputs (green wavelength) instead of inputs of different wavelengths. PCA outperforms ICA for more homogeneous input signals. Moreover, for high input SNR, the application of ICA using standard contrast is likely to decrease the SNR.

1 May 2017 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
ATAlexander Trumpp
Alexander Trumpp
PBPhilipp L. Bauer
Philipp L. Bauer
SRStefan Rasche
Stefan Rasche
HMHagen Malberg
Hagen Malberg
SZSebastian Zaunseder
Sebastian Zaunseder
Camera-based photoplethysmography (cbPPG) is a novel measuring technique that permits the remote acquisition of cardiovascular signals using video cameras. Research still lacks in fundamental studies to reach a deeper technical and physiological understanding. This work analyzes the employment of polarization filtration to (i) assess the gain for the signal quality and (ii) draw conclusions about the cbPPG signal’s origin. We evaluated various forehead regions of 18 recordings with different color and filter settings. Our results prove that for an optimal illumination, the perpendicular filter setting provides a significant benefit. The outcome supports the theory that signals arise from blood volume changes. For lateral illumination, ballistocardiographic effects dominate the signal as polarization’s impact vanishes.

1 September 2016 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
ATAlexander Trumpp
Alexander Trumpp
JSJoachim Schell
Joachim Schell
HMHagen Malberg
Hagen Malberg
SZSebastian Zaunseder
Sebastian Zaunseder
Camera-based photoplethysmography (cbPPG) is a novel technique that allows the contactless acquisition of cardio-respiratory signals. Previous works on cbPPG most often focused on heart rate extraction. This contribution is directed at the assessment of vasomotor activity by means of cameras. In an experimental study, we show that vasodilation and vasoconstriction both lead to significant changes in cbPPG signals. Our findings underline the potential of cbPPG to monitor vasomotor functions in real-life applications.