Philip Rauen

Philip Rauen

Auto-generated profile, based on publicly available information

Philip Rauen

Faculty of Medicine and University Hospital Cologne, University of Cologne, Institute for Diagnostic and Interventional Radiology, Cologne, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2023 in Radiology
Verified
Journal Article
Closed access
JKJonathan Kottlors
Jonathan Kottlors
GBGrischa Bratke
Grischa Bratke
PRPhilip Rauen
Philip Rauen
CKChristoph Kabbasch
Christoph Kabbasch
TPThorsten Persigehl
Thorsten Persigehl
SLSimon Lennartz
Simon Lennartz

24 September 2024 in Clinical Neuroradiology
Verified
Journal Article
Open access
PDF file
JJJan P. Janssen
Jan P. Janssen
SRSarah Rose
Sarah Rose
KKKenan Kaya
Kenan Kaya
RTRobert Terzis
Robert Terzis
RHRobert Hahnfeldt
Robert Hahnfeldt
CGCarsten Herbert Gietzen
Carsten Herbert Gietzen
Purpose: To evaluate a novel flow-independent sequence (Relaxation-Enhanced Angiography without Contrast and Triggering (REACT)) for imaging of the extracranial arteries in acute ischemic stroke (AIS) at 1.5 T. Methods: This retrospective single-center study included 47 AIS patients who received REACT (scan time: 3:01 min) and contrast-enhanced MRA (CE-MRA) of the extracranial arteries at 1.5 T in clinical routine. Two radiologists assessed scans for proximal internal carotid artery (ICA) stenosis, stated their diagnostic confidence and rated the image quality of cervical arteries, impact of artifacts and image noise. Apparent signal- and contrast-to-noise ratios (aSNR/aCNR) were measured for the common carotid artery and ICA. Results: REACT achieved a sensitivity of 95.0% and a specificity of 97.3% for ICA stenoses in high agreement with CE-MRA (κ = 0.83) with equal diagnostic confidence (p = 0.22). Image quality was rated higher for CE-MRA at the aortic arch (p = 0.002) and vertebral arteries (p < 0.001), whereas REACT provided superior results for the extracranial ICA (p = 0.008). Both sequences were only slightly affected by artifacts (p = 0.60), while image noise was more pronounced in CE-MRA (p < 0.001) in line with higher aSNR (p < 0.001) and aCNR (p < 0.001) values in REACT for all vessels. Conclusion: Given its good diagnostic performance while yielding comparable image quality and scan time to CE-MRA, REACT may be suitable for the imaging of the extracranial arteries in acute ischemic stroke at 1.5 T.