Intelligent Control and Smart Energy (ICSE) Research Group, School of Engineering, University of Warwick, Coventry, U.K.

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 October 2021 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
KJKe Jia
Ke Jia
QLQian Liu
Qian Liu
BYBin Yang
Bin Yang
LZLiming Zheng
Liming Zheng
YFYu Fang
Yu Fang
TBTianshu Bi
Tianshu Bi
Fault characteristics analysis normally provides a theoretical foundation for the protection design. Although conventional fault analysis of inverter-interfaced renewable energy sources (IIRESs) can characterize post-fault steady-state at the power frequency, it might not effectively present the fault transient. This can negatively affect the protection based on fault transient data within 20–30 ms after a grid fault. Thus, the fault transient of IIRESs needs to be fully investigated. Given this, the nonlinear effect of controller saturation is considered in this study. The domain of attraction (DOA) is first established to estimate the practical working state of the controller within the current loop. The transient fault current (TFC) analytical model is then proposed in accordance with the nonlinear control response of the controller under different working stages, which reveals a detailed transient transition of the fault current. Meanwhile, the proposed model is low-order and presents high applicability in different fault scenarios. Simulation results indicate that the TFC analytical accuracy obtained using the proposed method is improved by at most 50% relative to the accuracy reported in published studies. Field short-circuit test data are ultimately used to verify the performance of the proposed TFC analytical model.

22 June 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
QLQian Liu
Qian Liu
KJKe Jia
Ke Jia
BYBin Yang
Bin Yang
LZLiming Zheng
Liming Zheng
TBTianshu Bi
Tianshu Bi
To adapt to the operation under asymmetric conditions, an increasing number of grid-following inverter-interfaced renewable energy sources (IIRESs) start to employ the decoupled sequence control (DSC). However, due to the variety and complexity of the positive and negative sequence components calculation (PNSCC) modes used for DSC, the fault response of IIRESs with DSC has rarely been studied using the analytical method. To this end, this article proposes a Laplace domain fault modeling method to investigate fault characteristics of IIRESs with DSC. The high-order and coupling features of commonly used PNSCC modes are analyzed, and then they are taken into account to establish a detailed fault model of IIRESs with DSC. To further apply the fault model to the practical fault analysis, different PNSCC modes are generalized to obtain a unified form, and thus a reduced-order fault model of IIRESs with DSC covering the complete fault phases can be yielded. Based on this model, contributing factors of the IIRES's fault response within different fault phases can be explored. Simulation and hardware-in-loop experiments indicate that this model can be applied to various fault scenarios with an error less than 7%, providing a theoretical foundation to support the protection scheme.

27 August 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
KJKe Jia
Ke Jia
LHLaiyun Hou
Laiyun Hou
QLQian Liu
Qian Liu
YFYu Fang
Yu Fang
LZLiming Zheng
Liming Zheng
TBTianshu Bi
Tianshu Bi
Short-circuit current analysis, especially transient current calculation, provides a basis for protection design. Because the control systems of inverter-interfaced renewable energy sources have a high degree of nonlinearity, it is difficult to analyze the transient current. To address this issue, in this work, a nonlinear differential equation of transient current of symmetrical fault is derived while considering the saturation characteristics of the current loop. Aiming at the solution of this nonlinear differential equation, an analysis method based on the phase plane is proposed, which makes use of the linear relationship between the current deviation and its derivative to simplify the direct determination of the nonlinear working state in the time domain. The analytical expression of the transient current can then be obtained by the inverse transform from the phase plane to the time domain. The proposed calculation method is verified by both simulations and field tests.

7 September 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
QLQian Liu
Qian Liu
KJKe Jia
Ke Jia
BYBin Yang
Bin Yang
LZLiming Zheng
Liming Zheng
TBTianshu Bi
Tianshu Bi
The accurate analytical fault analysis model of the emerging inverter-interfaced renewable energy sources (IIRESs) is an important basis for protection of power system with RESs. However, factors of dynamic characteristics of the control system (DCCS) such as the controller saturation and phase-locked loop (PLL) dynamics have rarely been simultaneously studied in the existing analytical models of IIRESs. As a result, the accurate analytical models can hardly be guaranteed. To address this issue, this paper proposes an analytical model for IIRESs taking DCCS into account to characterize the complex fault responses of IIRESs. Both the controller saturation and PLL dynamics are considered in the transient and steady-state phases to investigate the fault current characteristics. On this basis, the analytical fault current formulations under the influences of DCCS are yielded using the piecewise linearization method. Field short-circuit and simulation tests indicate that the proposed model is applicable to various fault conditions and its calculation accuracy can be improved by at most 55% in comparison with the existing IIRESs’ analytical models.

27 June 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
BYBin Yang
Bin Yang
KJKe Jia
Ke Jia
QLQian Liu
Qian Liu
LZLiming Zheng
Liming Zheng
TBTianshu Bi
Tianshu Bi
This paper proposes a faulted line-section location method using sparse meters for the distribution networks (DNs) with high penetration of inverter interfaced distributed generations (IIDGs). By modeling the IIDGs as equivalent impedances instead of current sources, the fault component model of the DN with IIDGs can be transferred from a multi-current feeding system towards the sole-current feeding system. On this basis, the Bayesian Compressed Sensing (BCS) algorithm is applied to achieve the sparse solution of the fault current to indicate the faulted line-section. Moreover, to reduce the required meters for monitoring the IIDGs, a node partition scheme is designed based on the analysis of IIDG with different control strategies. The proposed fault location method requires only 15 meters for an IEEE 69-node distribution network with 20 IIDGs. Simulation results show that the location success rate is beyond 95% for various fault scenarios which is a 55% improvement over the existing BCS-based method.