21 October 2021 in Matter and Radiation at Extremes
We present the results of the first commissioning phase of the short-focal-length area of the Apollon laser facility (located in Saclay, France), which was performed with the first available laser beam (F2), scaled to a nominal power of 1 PW. Under the conditions that were tested, this beam delivered on-target pulses of 10 J average energy and 24 fs duration. Several diagnostics were fielded to assess the performance of the facility. The on-target focal spot and its spatial stability, the temporal intensity profile prior to the main pulse, and the resulting density gradient formed at the irradiated side of solid targets have been thoroughly characterized, with the goal of helping users design future experiments. Emissions of energetic electrons, ions, and electromagnetic radiation were recorded, showing good laser-to-target coupling efficiency and an overall performance comparable to that of similar international facilities. This will be followed in 2022 by a further commissioning stage at the multi-petawatt level.
8 October 2024 in Physical Review Letters
We generate a tabletop pulsed relativistic electron beam at 100 Hz repetition rate from vacuum laser acceleration by tightly focusing a radially polarized beam into a low-density gas. We demonstrate that strong longitudinal electric fields at the focus can accelerate electrons up to 1.43 MeV by using only 98 GW of peak laser power. The electron energy is measured as a function of laser intensity and gas species, revealing a strong dependence on the atomic ionization dynamics. These experimental results are supported by numerical simulations of particle dynamics in a tightly focused configuration that take ionization into consideration. For the range of intensities considered, it is demonstrated that atoms with higher atomic numbers like krypton can favorably inject electrons at the peak of the laser field, resulting in higher energies and an efficient acceleration mechanism that reaches a significant fraction (≈14%) of the theoretical energy gain limit.
1 October 2020 in Review of Scientific Instruments
We report on the cross-calibration of Thomson Parabola (TP) and Time-of-Flight (TOF) detectors as particle diagnostics, implemented on the most recent setup of the ALLS 100 TW laser-driven ion acceleration beamline. The Microchannel Plate (MCP) used for particle detection in the TP spectrometer has been calibrated in intensity on the tandem linear accelerator at the Université de Montréal. The experimental data points of the scaling factor were obtained by performing a pixel cluster analysis of single proton impacts on the MCP. A semi-empirical model was extrapolated and fitted to the data to apply the calibration also to higher kinetic energies and to extend it to other ion species. Two TOF lines using diamond detectors, placed at +6° and −9° with respect to the target-normal axis, were benchmarked against the TP spectrometer measurements to determine the field integrals related to its electric and magnetic dispersions. The mean integral proton numbers obtained on the beamline were about 4.1 × 1011 protons/sr with a standard deviation of 15% in the central section of the spectrum around 3 MeV, hence witnessing the high repeatability of the proton bunch generation. The mean maximum energy was of 7.3 ± 0.5 MeV, well in agreement with similar other 100 TW-scale laser facilities, with the best shots reaching 9 MeV and nearly 1012 protons/sr. The used particle diagnostics are compatible with the development of a high-repetition rate targetry due to their fast online readout and are therefore a crucial step in the automation of any beamline.
1 August 2019 in Review of Scientific Instruments
In this work, we calibrate the newly developed EBT-XD radiochromic films (RCFs) manufactured by Gafchromictm using protons in the energy range of 4–10 MeV. Irradiation was performed on the 2 × 6 MV tandem linear accelerator located at the Université de Montréal. The RCFs were digitized using an Epson Perfection V700 flatbed scanner using both the red-green-blue and grayscale channels. The proton fluences were measured with Faraday cups calibrated in absolute terms. The linear energy transfer function within the active layer of the films was calculated using the mass stopping power tables coming from the PSTAR database from the National Institute of Standards and Technology (NIST) to allow retrieval of the deposited dose. We find that the calibration curves for 7 and 10 MeV protons are nearly equivalent. The 4 MeV calibration curves exhibit a quenching effect due to the Bragg peak that falls close to the active layer. A linearization of this energy dependence was developed using a semiempirical parametric model to allow the generation of calibration curves for any incident proton energy within the present range. Excellent correspondence (<5% dose difference for the same netOD) of the 10 MeV calibration curves was noted when compared to existing high-energy proton (148.2 MeV) calibration curves reported in the literature. Our calibration extends the range of operation of EBT-XD films to low-energy proton beam dosimetry.
25 May 2023 in Optics Express
FFFrançois Fillion-Gourdeau
François Fillion-Gourdeau
+1
A comparative study of three different tight-focusing schemes for high-power lasers is performed numerically. Using the Stratton-Chu formulation, the electromagnetic field in the vicinity of the focus is evaluated for a short-pulse laser beam incident upon an on-axis high numerical aperture parabola (HNAP), an off-axis parabola (OAP), and a transmission parabola (TP). Linearly- and radially-polarized incident beams are considered. It is demonstrated that while all the focusing configurations yield intensities above 1023 W/cm2 for a 1 PW incident beam, the nature of the focused field can be drastically modified. In particular, it is shown that the TP, with its focal point behind the parabola, actually converts an incoming linearly-polarized beam into an m = 2 vector beam. The strengths and weaknesses of each configuration are discussed in the context of future laser-matter interaction experiments. Finally, a generalization of NA calculations up to 4π-illumination is proposed through the solid angle formulation, providing a universal way to compare light cones from any kind of optics.
1 May 2022 in New Journal of Physics
In this work, we demonstrate the feasibility of quantitative laser-based x-ray fluorescence (XRF) combined with particle-induced x-ray emission (PIXE) (called XPIF for x-ray and particle-induced fluorescence) spectroscopy analysis for elemental composition in solid samples. A multi-hundred TW laser system accelerated protons and produced x-rays that were impinging on solid samples, inducing characteristic line emissions of the elements contained in the material. The x-ray yield obtained from the characteristic emissions for each element can be related to its mass concentration using both the thick PIXE and thick XRF formalism. This is performed by using of an iterative numerical procedure. We tested the validity of our method on three homogeneous metallic materials, stainless steel, bronze and brass. The mass proportions of these samples retrieved by our analysis (XPIF) is within the errors bars compared with a commercial energy dispersive x-ray spectrometer.