Charles Bienvenue

Charles Bienvenue

Auto-generated profile, based on publicly available information

Charles Bienvenue

INRS-EMT, 1650 Blvd. Lionel-Boulet, Varennes, Quebec J3X 1P7, Canada

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
SVS. Vallières
S. Vallières
CBC. Bienvenue
C. Bienvenue
PPP. Puyuelo-Valdes
P. Puyuelo-Valdes
MSM. Salvadori
M. Salvadori
EDE. D’hUmières
E. D’hUmières
PAP. Antici
P. Antici
In this work, we calibrate the newly developed EBT-XD radiochromic films (RCFs) manufactured by Gafchromictm using protons in the energy range of 4–10 MeV. Irradiation was performed on the 2 × 6 MV tandem linear accelerator located at the Université de Montréal. The RCFs were digitized using an Epson Perfection V700 flatbed scanner using both the red-green-blue and grayscale channels. The proton fluences were measured with Faraday cups calibrated in absolute terms. The linear energy transfer function within the active layer of the films was calculated using the mass stopping power tables coming from the PSTAR database from the National Institute of Standards and Technology (NIST) to allow retrieval of the deposited dose. We find that the calibration curves for 7 and 10 MeV protons are nearly equivalent. The 4 MeV calibration curves exhibit a quenching effect due to the Bragg peak that falls close to the active layer. A linearization of this energy dependence was developed using a semiempirical parametric model to allow the generation of calibration curves for any incident proton energy within the present range. Excellent correspondence (<5% dose difference for the same netOD) of the 10 MeV calibration curves was noted when compared to existing high-energy proton (148.2 MeV) calibration curves reported in the literature. Our calibration extends the range of operation of EBT-XD films to low-energy proton beam dosimetry.

1 December 2019 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
CBC. Bienvenue
C. Bienvenue
SVS. Vallières
S. Vallières
SPS. Payeur
S. Payeur
PAP. Antici
P. Antici
We present a Target Positioning Interferometer (TPI), a system that uses variations of the wavefront curvature to position solid reflective surfaces with submicrometric precision. The TPI is a Michelson interferometer into which a lens is inserted in the target arm and the mirror of the reference arm is slightly tilted. The TPI configuration presented in this work allows us to position the surface of a reflective target on a beam focus within an uncertainty of 350 nm (2σ) in a subsecond timeframe, using a lens with a numerical aperture of NA = 0.20. We support our experimental findings with numerical simulations of the interference pattern using the ABCD matrices’ method, allowing us to define scaling laws for using the TPI with different optics and environments, as well as suggestions to improve the TPI accuracy and adapt the system to different applications. This system is very well suited for accurate and repeatable target positioning used in laser-driven ion acceleration, where a precise alignment is key to optimize the proton acceleration mechanism.

13 January 2025 in Journal of Computational Physics
Verified
Journal Article
Open access
CBCharles Bienvenue
Charles Bienvenue
ANAhmed Naceur
Ahmed Naceur
AHAlain Hébert
Alain Hébert
JCJean-François Carrier
Jean-François Carrier

4 November 2022 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
ANAhmed Naceur
Ahmed Naceur
GFGabriel Famulari
Gabriel Famulari
CBCharles Bienvenue
Charles Bienvenue
JCJean-François Carrier
Jean-François Carrier
AHAlain Hébert
Alain Hébert
Fully coupled photon-electron-positron computational schemes are needed in a broad range of domains, from radiotherapy and radiosurgery treatment planning to nuclear-reactor safety analysis. Industrial deployment of such schemes remains problematic because of the prohibitively time-consuming charged-particle-transport aspects of both Monte Carlo algorithms and Boltzmann-Fokker-Planck solvers. In this paper, a partially coupled scheme based on reactor-physics models for secondary photons (RPSPs) is presented. RPSPs include thick-target-bremsstrahlung, annihilation, and full atomic cascade models, recovering long-range effects of both electrons and positrons. The RPSP-based scheme is compared with state-of-the-art fully coupled and uncoupled schemes in medical, nuclear, and multidisciplinary contexts. Within tissues, the average discrepancies from the fully coupled scheme are about 0.5%, with a maximum error below 1.3% at high energy. The CPU time of the coupled schemes is reduced by 58 and 78 times for 3- and 6-MeV beams, respectively. The discrepancies are also within the accuracy of the cross sections for 4Be, 6C, 13Al, 26Fe, 29Cu, 32Ge, 47Ag, 79Au, 82Pb, and 92U slabs. The same discrepancies are about 0.1%, 0.4% and 0.8%, respectively, in the reactor's shielding, vessel and fuel slabs. A power peaking factor reduction of 4.35 times from the state-of-the-art uncoupled scheme is demonstrated for uranium oxide and mixed plutonium-uranium oxide slabs.

8 April 2025 in Nuclear Science and Engineering
Verified
Journal Article
Open access
CBCharles Bienvenue
Charles Bienvenue
ANAhmed Naceur
Ahmed Naceur
JCJean-François Carrier
Jean-François Carrier
AHAlain Hébert
Alain Hébert