30 September 2022 in Neurospine
Objective: Three-dimensional (3D)-printed titanium implants have been developed recently, but the utility is not yet proven. The aim of this study was to compare 3D-printed titanium and polyetheretherketone (PEEK) implants after minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF).Methods: Between October 2018 and September 2021, we retrospectively analyzed 83 patients who underwent single-level MIS-TLIF (3D-printed titanium, 40; PEEK, 43). Radiologic parameters were assessed with x-ray and computed tomography (CT) at postoperative 1 week, 6 months, and 1 year. Clinical status was evaluated using Oswestry Disability Index, visual analogue scale score, and Bridwell fusion grading was assessed on 6-month and 1-year postoperative CT.Results: There were no differences between the 2 groups in demographics and clinical outcomes. At 1-year of follow-up, the reported 3D-printed titanium fusion grades were grade I: 77.5% (31 patients), grade II: 17.5% (7 patients), and grade III: 5% (2 patients). The PEEK fusion grades were grade I: 51.2% (22 patients), grade II: 41.9% (18 patients), and grade III: 7.0% (3 patients). For overall fusion rate (grade I + II), there was no difference between the 2 cages (95.0% vs. 93.0%, p = 0.705), but grade I was reported at a higher incidence in 3D-printed titanium than PEEK (77.5% vs. 51.2%, p = 0.013). There was no difference between cages based on subsidence and complications.Conclusion: There were no significant differences in the overall fusion rate for MIS-TLIF surgery between 3D-printed titanium and PEEK, but the fusion grade was better in 3D-printed titanium than in PEEK. Long-term follow-up is required to verify the effectiveness.
1 January 2021 in Journal of Korean Neurosurgical Society
Although stent-assisted coiling (SAC) has been reported to be safe and effective in treating wide-necked aneurysms, the technique has procedure-related complications. Thus, we reported our experiences of SAC using the Neuroform Atlas stent in treating wide-necked aneurysms and evaluated the incidence of and risk factors for procedure-related complications. From March 2018 to August 2019, we treated 130 unruptured wide-necked aneurysms in 123 patients with Neuroform Atlas stents. Angiographic results and clinical outcomes were reviewed retrospectively. Clinical and angiographic follow-up were performed in all cases (mean, 12.4 months) after the procedure. There were eight cases (6.2%) of procedure-related complications (two dissections, five thromboembolisms, and one hemorrhage) and two (1.5%) of delayed complications (one ischemia and one hemorrhage). There was one case (0.8%) of failure of stent deployment and one (0.8%) of suboptimal positioning of the stent. Follow-up angiography showed complete obliteration in 103 (79.2%), residual neck in 16 (12.3%), and residual aneurysm in 11 cases (8.5%). Aneurysm locations in the middle cerebral artery (odds ratio [OR], 2.211; p=0.046) and the anterior communicating artery (OR, 2.850; p=0.039) were associated with procedure-related complications on univariate analysis. However, no independent risk factor for procedure-related complications was noted in multivariate analysis. The Neuroform Atlas showed a high rate of technical success. Good clinical and radiographic outcomes in early follow-up suggests that the device is feasible and safe. SAC of aneurysms on the middle cerebral artery or anterior communicating artery may require more attention to prevent possible procedure-related complications.