Bao Doan Thanh

Bao Doan Thanh

Auto-generated profile, based on publicly available information

Bao Doan Thanh

Faculty of Engineering and Technology, Quy Nhon University, Gia Lai, Vietnam

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2024 in CTU Journal of Innovation and Sustainable Development
Verified
Journal Article
Open access
PDF file
HPHong Hai Pham
Hong Hai Pham
BTBao Doan Thanh
Bao Doan Thanh
The study used the Finite element method (FEM) by ANSYS 3D software to calculate the distribution of electromagnetic force (EMF) and temperature on the high voltage and low voltage windings (HLVWs) of the amorphous steel core 3 phase transformer (ASCT) which has a power of 1000kVA –22/0.4kV under different load cases: No load, full load and short circuit (SC). The obtained results show the exact temperature distribution and location where the highest temperature is found on the HLVWs of ASCT. From the analysis of the temperature distribution on the HLVWs, it is shown that when the transformer falls into an SC fault, it causes the greatest EMF and thermodynamic force, causing extremely heavy consequences for the transformers. The obtained results help designers, manufacturers, and operators have the most suitable options to improve strength of SC and increase the life of the transformer.

19 June 2023 in Archives of Electrical Engineering
Verified
Journal Article
Closed access
PDF file
BTBao Doan Thanh
Bao Doan Thanh
DTDoan Duc Tung
Doan Duc Tung
TLTuan-Ho Le
Tuan-Ho Le
Electromagnetic forces generated by the short circuit current and leakage flux in low- and high-voltage windings of distribution transformers as well as amorphous core transformers will cause the translation, destruction, and explosion of the windings. Thus, the investigation of these forces plays a significant role for researchers and manufacturers. Many authors have recently used the finite element method to analyze electromagnetic forces. In this paper, an analytic model is first developed for magnetic vector potential formulations to compute the electromagnetic forces (i.e., axial and radial forces) acting on the low- and high-voltage windings of an amorphous core transformer. The finite element technique is then presented to validate the results obtained from the analytical model. The developed model is applied to an actual problem.

31 July 2025 in Journal of Electromagnetic Engineering and Science
Verified
Journal Article
Open access
PDF file
TCTrinh Truong Cong
Trinh Truong Cong
BTBao Doan Thanh
Bao Doan Thanh
DMDinh Bui Minh
Dinh Bui Minh
Gia Minh Thao NGUYENGia Minh Thao NGUYEN
Gia Minh Thao NGUYEN
QDQuoc-Vuong DANG
Quoc-Vuong DANG
Permanent magnet synchronous motors (PMSMs) have been extensively adopted in a range of industrial applications, particularly in the electric vehicle industry, due to their high power and torque density, high efficiency, reliability, and excellent dynamic performance. Between the types of PMSMs, a surface-mounted PMSM (SPMSM) is characterized by identical d- and q-inductances, due to which it only generates magnetic torque. However, SPMSMs also exhibit higher flux density, since the air gap in these motors is smaller and the permanent magnets are located very close to the stator teeth. In contrast, an interior PMSM (IPMSMs) features different d-axis and q-axis inductance components, due to which it can create not only magnetic torque but also reluctance torque. In this paper, two processes are conducted to examine these motors. First, an analytical technique is proposed to design the required parameters for an SPMSM and an IPMSM, where the dimensions of the latter are defined using the fractional-slot concentrated winding configuration, and those of the former are designed based on the approach of keeping the rotor volume, permanent magnet volume, pole–slot combination, and power supply unchanged. Subsequently, a finite element method is presented for computing, simulating, and comparing the electromagnetic parameters of both proposed motors, including their back electromotive force, torque ripple, efficiency, and power factor. Finally, the proposed methods are validated using a 7.5 kW practical motor.

25 July 2023 in International Journal of Applied Power Engineering (IJAPE)
Verified
Journal Article
Open access
PDF file
HDHung Bui Duc
Hung Bui Duc
TMTu Pham Minh
Tu Pham Minh
BTBao Doan Thanh
Bao Doan Thanh
DNDuc-Quang Nguyen
Duc-Quang Nguyen
QDQuoc-Vuong DANG
Quoc-Vuong DANG
The finite element technique is used widely for researchers and manufacturers to design and simulate electrical systems in general and electrical machines such as shunt reactors (SRs) and transformers in particular. Many papers have recently applied several methods to analyze magnetic fields, copper losses and joule power losses in the shunt reactors (SRs). In this research, the finite element technique with coupling to global quantities is proposed to investigate the voltage and current distributions in the windings, and compute the distribution of magnetic field in the air gap and along the air core of the SR, as well as copper and core losses. The developed method is directly applied to the practical SR of 91 MVAr and a rated voltage of 500 kV. The finite element method (FEM)-simulated results are validated with experimental results to ensure accuracy and reliability. This facilitate designing the reactor.

1 December 2024 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Verified
Journal Article
Open access
PDF file
HHHoang Bui Huu
Hoang Bui Huu
BTBao Doan Thanh
Bao Doan Thanh
TCTran Duc Chuyen
Tran Duc Chuyen
QDQuoc-Vuong DANG
Quoc-Vuong DANG
The surface-mounted permanent magnet synchronous motor (SPMSM) is one of the electric machines applied widely in the fields of electric vehicles (EVs) and electrical drives due to their good characteristics such as high power density, lower mass, high efficiency, and lower torque. For the SPMSM, there are two types of SPMSM, i.e., the inner rotor SPMSM and the outer rotor SPMSM. To analyze and compute advantages and disadvantages, as well as to compare the performances of these two motor types, this research proposes an analytical model to design preliminarily the main/required parameters of the SPMSM with inner and outer rotor types. Subsequently, a finite element method is developed to simulate, analyze, and compare the electromagnetic parameters of the proposed motors. Via the developed methods, the obtained results will also indicate the performances of both types of motors. In particular, it will provide a good recommendation for choosing the SPMSM with an inner or outer rotor structure for traction applications.

27 May 2026 in Smart Systems and Devices
Verified
Journal Article
Open access
PDF file
LVLoi Tran Van
Loi Tran Van
HTHo Nguyen Thao
Ho Nguyen Thao
TVTrung Ho Van
Trung Ho Van
BTBao Doan Thanh
Bao Doan Thanh
DLDinh Duong Le
Dinh Duong Le
AKAnh Nguyen Kim
Anh Nguyen Kim
The growing demand for electrical energy, together with increasingly complex operating conditions caused by nonlinear loads and the widespread integration of renewable energy sources, has led to increased harmonic distortion in power systems. As critical assets in distribution networks, transformers are particularly vulnerable to harmonic-induced losses and thermal stress, which can accelerate insulation aging and reduce service life. This study investigates the thermal effects of harmonics on a medium-voltage distribution transformer using a coupled electromagnetic–thermal approach based on the finite element method. In the proposed workflow, ANSYS Maxwell is used to compute electromagnetic quantities and harmonic-dependent losses, and these losses are then used as inputs to an equivalent electro-thermal model to predict top-oil and winding hot-spot temperatures. The electromagnetic model is validated under no-load and short-circuit conditions, and simulations are conducted for linear and nonlinear loads at 50%, 100%, and 125% of rated load. The hybrid thermal prediction results show good agreement with detailed ANSYS Mechanical simulations, with a deviation of approximately 3% in the linear-load case and 0.016% in the nonlinear-load case. The results show that harmonic loading significantly increases load-related losses and hot-spot temperature, while also revealing a non-uniform temperature distribution that enables hot-spot localization. The obtained spatial hot-spot information supports insulation loss-of-life assessment and provides practical guidance for design improvement, sensor placement, periodic inspection/testing, spare-part planning, and condition-based maintenance under harmonic operating conditions.