In this paper, we propose a new scheme for probabilistic power flow in networks with renewable power generation by making use of a data clustering technique. The proposed clustering technique is based on the combination of Principal Component Analysis and Differential Evolution clustering algorithm to deal with input random variables in probabilistic power flow. Extensive testing on the modified IEEE-118 bus test system shows good performance of the proposed approach in terms of significant reduction of computation time compared to the traditional Monte Carlo simulation, while maintaining an appropriate level of accuracy.
25 June 2021 in International Journal of Renewable Energy Development
The increasing penetration of renewable energy sources has introduced great uncertainties and challenges into computation and analysis of electric power systems. To deal with uncertainties, probabilistic approaches need to be used. In this paper, we propose a new framework for probabilistic assessment of power systems taking into account uncertainties from input random variables such as load demands and renewable energy sources. It is based on the cumulant-based Probabilistic Power Flow (PPF) in combination with an improved clustering technique. The improved clustering technique is also developed in this study by making use of Principal Component Analysis (PCA) and Particle Swarm Optimization (PSO) to reduce the range of variation in the input data, thus increasing the accuracy of the traditional cumulant-based PPF (TCPPF) method. In addition, thanks to adopting PCA for dimensionality reduction, the improved clustering technique can be effectively dealt with a large number of input random variables so that the proposed framework for probabilistic assessment can be applied for large power systems. The IEEE-118 bus test system is modified by adding five wind and eight solar photovoltaic power plants to examine the proposed method. Uncertainties from input random variables are represented by appropriate probabilistic models. Extensive testing on the test system indicates good performance of the proposed approach in comparison to the traditional cumulant-based PPF and Monte Carlo simulation. The IEEE-118 bus test system is modified by adding five wind and eight solar photovoltaic power plants to examine the proposed method. Extensive testing on the test system, using Matlab (R2015a) on an Intel Core i5 CPU 2.53 GHz/4.00 GB RAM PC, indicates good performance of the proposed approach (PPPF) in comparison to the TCPPF and Monte Carlo simulation (MCS): In terms of computation time, PPPF needs 4.54 seconds, while TCPPF and MCS require 2.63 and 251 seconds, respectively; ARMS errors are calculated for methods using benchmark MCS and their values clearly demonstrate the higher accuracy of PPPF in estimating probability distributions compared to TCPPF, i.e., the maximum (Max) and mean (Mean) values of ARMS errors of all output random variables are: ARMSPPPFmax = 0.11%, ARMSTCPPFmax = 0.55%, and ARMSPPPFmean = 0.06%, ARMSTCPPFmean = 0.35%.
For power systems with long-distance ultra-high-voltage (UHV) transmission lines, power transmission limits are often determined by static stability limits. Therefore, the assessment of stability and finding solutions to improve the stability reserve are essential for the operation of the system. This article presents an analytical approach to construct limit characteristics according to static stability conditions on a power plane. Based on the approach proposed, a program is developed and tested on a system with long-distance UHV transmission lines, showing a good performance.
Today, renewable energy sources (RESs) are increasingly being integrated into power systems. This means adding more sources of uncertainty to the power system. To deal with the uncertainty of input random variables (RVs) in power system calculation and analysis problems, probabilistic power flow (PPF) techniques have been introduced and proven to be effective. Currently, although there are many techniques proposed for solving the PPF problem, the Monte Carlo simulation (MCS) method is still considered as the method with the highest accuracy and its results are used as a reference for the evaluation of other methods. However, MCS often requires very high computational intensity, and this makes practical application difficult, especially with large-scale power systems. In the current paper, an advanced data clustering technique is proposed to process input RV data in order to the decrease computational burden of solving the PPF problem while upholding an acceptable level of accuracy. The proposed method can be effectively applied to solve practical problems in the operating time horizon of power systems. The developed approach is tested on the modified IEEE-300 bus system, indicating good performance in reducing computation time.
Accurately estimating the remaining useful life (RUL) of power transformers is critical for maintaining the reliability and efficiency of electrical power systems. This study proposes a novel empirical model to estimate the degree of polymerization (DP) - a critical measure of insulation deterioration in transformers - by analyzing 2-furfuraldehyde (2-FAL) concentration. Developed using a dataset of 125 samples from published literature, the model employs logarithmic regression to capture the exponential relationship between 2-FAL accumulation and insulation deterioration. Validation through comparison with Chengdong's model and other existing approaches, with performance metrics including and R-square of 0.9917, mean absolute error (MAE) of 58.08, and root mean square error (RMSE) of 86.59. The model's predictions for 2-FAL concentration in ranges of 0–5 ppm and 0–40 ppm closely align with the measured DP values. More specifically, it reflects a rapid initial decline followed by gradual stabilization at higher concentrations. The high-precision DP estimation enhances RUL prediction accuracy, offering a robust foundation for data-driven maintenance strategies for power transformers.
The growing demand for electrical energy, together with increasingly complex operating conditions caused by nonlinear loads and the widespread integration of renewable energy sources, has led to increased harmonic distortion in power systems. As critical assets in distribution networks, transformers are particularly vulnerable to harmonic-induced losses and thermal stress, which can accelerate insulation aging and reduce service life. This study investigates the thermal effects of harmonics on a medium-voltage distribution transformer using a coupled electromagnetic–thermal approach based on the finite element method. In the proposed workflow, ANSYS Maxwell is used to compute electromagnetic quantities and harmonic-dependent losses, and these losses are then used as inputs to an equivalent electro-thermal model to predict top-oil and winding hot-spot temperatures. The electromagnetic model is validated under no-load and short-circuit conditions, and simulations are conducted for linear and nonlinear loads at 50%, 100%, and 125% of rated load. The hybrid thermal prediction results show good agreement with detailed ANSYS Mechanical simulations, with a deviation of approximately 3% in the linear-load case and 0.016% in the nonlinear-load case. The results show that harmonic loading significantly increases load-related losses and hot-spot temperature, while also revealing a non-uniform temperature distribution that enables hot-spot localization. The obtained spatial hot-spot information supports insulation loss-of-life assessment and provides practical guidance for design improvement, sensor placement, periodic inspection/testing, spare-part planning, and condition-based maintenance under harmonic operating conditions.