Hans-Joachim Karl Menzel

Hans-Joachim Karl Menzel

Auto-generated profile, based on publicly available information

Hans-Joachim Karl Menzel

Departamento de Esportes, Universidade Federal de Minas Gerais , Belo Horizonte , Brazil

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2013 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
HMHans-Joachim Menzel
Hans-Joachim Menzel
MCMauro H. Chagas
Mauro H. Chagas
LSLeszek A. Szmuchrowski
Leszek A. Szmuchrowski
SASilvia R.S. Araujo
Silvia R.S. Araujo
AAANDRE GUSTAVO PEREIRA DE ANDRADE
ANDRE GUSTAVO PEREIRA DE ANDRADE
FJFabianna Resende de Jesus-Moraleida
Fabianna Resende de Jesus-Moraleida
Assessment of lower extremity bilateral asymmetries in soccer players is important for both injury prevention and performance. The purpose of this investigation was to compare isokinetic knee extensor assessment of asymmetry with a more specific countermovement jump (CMJ). Forty-six Brazilian male professional soccer players participated in this study. The maximal power, maximal force and impulse were determined during CMJ and the total work and peak torque at 60, 180, and 300°·s during isokinetic leg extension, separately for each leg. Factor analysis was performed for all investigated variables, and the diagnostic concordance between different criteria was analyzed by McNemar's χ test. The factor analysis showed that the isokinetic and CMJ tests were widely independent methods for the assessment of bilateral differences. Concordance of the diagnostic information could only be found between the maximal force during CMJ and the total work and peak torque at 180 and 300°·s during isokinetic leg extension. Impulse and maximal power during CMJ on a double force platform appear to be appropriate additional variables for the identification of bilateral differences. Therefore, it might be pertinent to perform, in addition to isokinetic assessment, a vertical jump test on a force platform to assure widespread and reliable diagnostic information.

6 July 2019 in Journal of Sports Sciences
Verified
Journal Article
Open access
Philip X. FuchsPhilip X. Fuchs
Philip X. Fuchs
HMHans-Joachim Karl Menzel
Hans-Joachim Karl Menzel
FGFlavia Guidotti
Flavia Guidotti
JBJeffrey Bell
Jeffrey Bell
SDSerge P. von Duvillard
Serge P. von Duvillard
HWHerbert Wagner
Herbert Wagner
There are well-known biological differences between women and men, especially in technical-coordinative variations that contribute to sex differences in performance of complex movements like the most important offensive action in volleyball, the spike jump. The aim of this study was to investigate sex-dependent performance and biomechanical characteristics in the volleyball spike jump. Thirty female and male sub-elite volleyball players were analysed while striking a stationary ball with maximal spike jump height. Twelve MX13 Vicon cameras with a cluster marker set, two AMTI force plates, surface EMG, and a Full-Body 3D model in Visual3D were used. Main findings include sex differences (P< .05) in jump height (pη2 = .73), approach [speed (pη2 = .61), step length], transition strategy [plant angle, neuromuscular activation (pη2 = .91), horizontal force maxima and impulses], acceleration distances [centre of mass displacement (pη2 = .21), minimal knee and hip angles], use of torso and arms [incline, angular velocity (pη2 = .23)]. Correlations support that the results cannot be explained fully by strength and power differences between sexes but represent the product of technical-coordinative variations. Their relevance is acknowledged for both sexes and numerous performance determinants displayed sex differences. The integration of such attributes into sex-specific training seems promising but its effect requires further investigation.

1 February 2010 in Perceptual and Motor Skills
Verified
Journal Article
Closed access
PDF file
HMHans-Joachim Menzel
Hans-Joachim Menzel
MCMauro H. Chagas
Mauro H. Chagas
LSLeszek A. Szmuchrowski
Leszek A. Szmuchrowski
SASilvia R. Araujo
Silvia R. Araujo
CCCarlos E. Campos
Carlos E. Campos
MGMarcus R. Giannetti
Marcus R. Giannetti
The objective was to estimate the reliability and criterion-related validity of the Jump-and-Reach Test for the assessment of squat, countermovement, and drop jump performance of 32 male Brazilian professional volleyball players. Performance of squat, countermovement, and drop jumps with different dropping heights was assessed on the Jump-and-Reach Test and the measurement of flight time, then compared across different jump trials. The very high reliability coefficients of both assessment methods and the lower correlation coefficients between scores on the assessments indicate a very high consistency of each method but only moderate covariation, which means that they measure partly different items. As a consequence, the Jump-and-Reach Test has good ecological validity in situations when reaching height during the flight phase is critical for performance (e.g., basketball and volleyball) but only limited accuracy for the assessment of vertical impulse production with different jump techniques and conditions.

1 September 2018 in Revista Brasileira de Medicina do Esporte
Verified
Journal Article
Open access
PDF file
JFJacielle Carolina Ferreira
Jacielle Carolina Ferreira
SASilvia Ribeiro Santos Araujo
Silvia Ribeiro Santos Araujo
EPEduardo Pimenta Pimenta
Eduardo Pimenta Pimenta
HMHans-Joachim Karl Menzel
Hans-Joachim Karl Menzel
FMFabíola Bertú Medeiros
Fabíola Bertú Medeiros
MCMauro Heleno Chagas
Mauro Heleno Chagas
Introduction: Muscular strength is an essential capacity for soccer players; however, the profile of this capacity has not yet been clearly established in young players. Objective: To compare muscular strength performance in the countermovement jump (CMJ) task and the presence of lower limb asymmetry among soccer athletes of the under 15 (U15), under 17 (U17) and under 20 (U20) categories, and between two teams of different competitive levels. Methods: One hundred and fifty one young soccer players of three different categories (U15, U17 and U20) from two teams in the Brazilian first and second divisions performed six vertical jumps in a system of two force plates. Ground reaction force (GRF) was used to calculate jump height and to obtain the variables Peak force (FMAX), Impulse (I) and Peak power (PMAX) with regard to body mass and the respective asymmetry values. Results: No differences were found in the performance and asymmetry variable between the categories (Jump height: p=0.23; FMAX: p=0.15; I: p=0.11; PMAX: p=0.32; FMAX asymmetry: p=0.21; I asymmetry: p=0.58; PMAX asymmetry: p=0.58). The first division club had higher muscle strength and asymmetry values than the second division club (Jump height: p<0.01; I: p<0.01; PMAX: p<0.01; FMAX asymmetry: p<0.01; I asymmetry: p<0.01; PMAX asymmetry: p<0.01), except for FMAX (p=0.63). No variable had an interaction effect (club x category). Conclusion: As categories progress, jump height, relative I, PMAX and FMAX values and their respective asymmetries are stable. The asymmetry and strength performance of the first division club were higher than that of the second division club, except for FMAX, indicating that the competitive level may influence strength performance and the development of asymmetry. Level of Evidence II; Diagnostic study – Investigating a diagnostic test.

16 May 2018 in Sports Biomechanics
Verified
Journal Article
Closed access
EAEdgardo Alvares de Campos Abreu
Edgardo Alvares de Campos Abreu
SASílvia Ribeiro Santos Araújo
Sílvia Ribeiro Santos Araújo
GCGustavo Henrique da Cunha Peixoto Cançado
Gustavo Henrique da Cunha Peixoto Cançado
AAANDRE GUSTAVO PEREIRA DE ANDRADE
ANDRE GUSTAVO PEREIRA DE ANDRADE
MCMauro Heleno Chagas
Mauro Heleno Chagas
HMHans-Joachim Karl Menzel
Hans-Joachim Karl Menzel
Sport climbers frequently use campus board (CB) to improve their upper limb strength under similar conditions of high-difficulty sport climbing routes. The objective of this study was to assess the test-retest reliability of peak force and impulse measured using a CB instrumented with two load cells on starting holds. The same evaluator examined 22 climbers on two days with 48 h between the assessments. The participants performed five concentric lunges (CL) and five lunges with stretch-shortening cycle with 1 min intervals between repetitions and 10 min between exercises. All variables were associated with significant intraclass correlation coefficient (ICC) values (p = 0.001), and none variable showed systematic errors (p > 0.05). Peak force ICC was higher than 0.88, and the standard error of measurement (SEM%) was less than 5%. Impulse ICC for the CL was greater than 0.90, and the SEM% was less than 14%. We conclude that the kinetic variables measured using the CB were reliable. The ability of the hands to maintain contact with the holds (peak force) and the abilities of the arms and shoulders vertically move the centre of mass (impulse) should be taken into account by coaches on CB training prescription as well for further research.

3 December 2018 in Revista da Educacao Fisica
Verified
Journal Article
Open access
PDF file
MOMariana Paulino Oliveira
Mariana Paulino Oliveira
HMHans-Joachim Karl Menzel
Hans-Joachim Karl Menzel
LSLeszek Antoni Szmuchrowski
Leszek Antoni Szmuchrowski
SNSeverino Leão de Albuquerque Neto
Severino Leão de Albuquerque Neto
TKTane Kanope
Tane Kanope
BCBruno Pena Couto
Bruno Pena Couto
O objetivo desse estudo foi verificar o efeito agudo da aplicação de vibração de corpo inteiro (VCI) sobre o impulso e sobre a força máxima de membros superiores. Vinte voluntários do sexo masculino, treinados, com idade: 23,8 ± 3,3 anos, foram submetidos a 3 sessões (uma sessão de familiarização e duas sessões de intervenção). Em cada uma das sessões de intervenção os voluntários realizaram uma contração voluntária máxima (CVM) de flexores do cotovelo sem aplicação de vibração e duas CVM com adição de vibração. Foram utilizadas 4 frequências de VCI (10, 20, 30 e 40Hz) distribuídas de maneira aleatória nas 4 CVM realizadas com vibração nas duas sessões de coleta. Os resultados encontrados mostraram que a força máxima e o impulso gerados na contração sem vibração foram significativamente maiores do que a força máxima e o impulso gerados durante a contração realizada com aplicação de VCI. Para o treinamento de força, a aplicação de VCI, nas frequências testadas na presente investigação, representou um menor estímulo de treinamento para os membros superiores, uma vez que gerou uma redução na força máxima e no impulso dos músculos flexores do cotovelo.