1 July 2018 in Osteoarthritis and Cartilage
1 March 2019 in Journal of Biomechanics
Marker-based dynamic functional or regression methods are used to compute joint centre locations that can be used to improve linear scaling of the pelvis in musculoskeletal models, although large errors have been reported using these methods. This study aimed to investigate if statistical shape models could improve prediction of the hip joint centre (HJC) location. The inclusion of complete pelvis imaging data from computed tomography (CT) was also explored to determine if free-form deformation techniques could further improve HJC estimates. Mean Euclidean distance errors were calculated between HJC from CT and estimates from shape modelling methods, and functional- and regression-based linear scaling approaches. The HJC of a generic musculoskeletal model was also perturbed to compute the root-mean squared error (RMSE) of the hip muscle moment arms between the reference HJC obtained from CT and the different scaling methods. Shape modelling without medical imaging data significantly reduced HJC location error estimates (11.4 ± 3.3 mm) compared to functional (36.9 ± 17.5 mm, p = <0.001) and regression (31.2 ± 15 mm, p = <0.001) methods. The addition of complete pelvis imaging data to the shape modelling workflow further reduced HJC error estimates compared to no imaging (6.6 ± 3.1 mm, p = 0.002). Average RMSE were greatest for the hip flexor and extensor muscle groups using the functional (16.71 mm and 8.87 mm respectively) and regression methods (16.15 mm and 9.97 mm respectively). The effects on moment-arms were less substantial for the shape modelling methods, ranging from 0.05 to 3.2 mm. Shape modelling methods improved HJC location and muscle moment-arm estimates compared to linear scaling of musculoskeletal models in patients with hip osteoarthritis.
6 January 2022 in IEEE Transactions on Biomedical Engineering
Objective: Using a musculoskeletal modelling framework, we aimed to (1) estimate knee joint loading using static optimization (SO); (2) explore different calibration functions in electromyogram (EMG)-informed models used in estimating knee load; and (3) determine, when using an EMG-informed stochastic method, if the measured joint loadings are solutions to the muscle redundancy problem when investigating only the uncertainty in muscle forces. Methods : Musculoskeletal models for three individuals with instrumented knee replacements were generated. Muscle forces were calculated using SO, EMG-informed, and EMG-informed stochastic methods. Measured knee joint loads from the prostheses were compared to the SO and EMG-informed solutions. Root mean square error (RMSE) in joint load estimation was calculated, and the muscle force ranges were compared. Results : The RMSE ranged between 192-674 N, 152-487 N, and 7-108 N for the SO, the calibrated EMG-informed solution, and the best fit stochastic result, respectively. The stochastic method produced solution spaces encompassing the measured joint loading up to 98% of stance. Conclusion: Uncertainty in muscle forces can account for total knee loading and it is recommended that, where possible, EMG measurements should be included to estimate knee joint loading. Significance: This work shows that the inclusion of EMG-informed modelling allows for better estimation of knee joint loading when compared to SO.
1 November 2016 in Journal of Science and Medicine in Sport
27 May 2021 in Journal of Bone and Joint Surgery
Update: This article was updated on July 19, 2021, because of a previous error. On page 1172, in the Results section entitled “Sedentary Activity,” the sentence that had read “Postoperatively, 32% at 1 year and 14% at 2 years were sedentary for >11 hours per day.” now reads “Postoperatively, 32% at 1 year and 41% at 2 years were sedentary for >11 hours per day.” Background: Despite marked improvements in self-reported pain, perceived functional ability, and gait function following primary total hip arthroplasty (THA), it remains unclear whether these improvements translate into improved physical activity and sleep behaviors. The aim of this study was to determine the change in 24-hour activity profile (waking activities and sleep) and laboratory-based gait function from preoperatively to 2 years following the THA. Methods: Fifty-one patients undergoing primary THA at a single public hospital were recruited. All THAs were performed using a posterior surgical approach with the same prosthesis type. A wrist-worn accelerometer was used to capture 24-hour activity profiles preoperatively and at 1 and 2 years postoperatively. Three-dimensional gait analysis was performed to determine changes in temporospatial and kinematic parameters of the hip and pelvis. Results: Patients showed improvements in all temporospatial and kinematic parameters with time. Preoperatively, patients were sedentary or asleep for a mean time (and standard deviation) of 19.5 ± 2.2 hours per day. This remained unchanged up to 2 years postoperatively (19.6 ± 1.3 hours per day). Sleep efficiency remained suboptimal (11 hours per day at 1 year (32%) and 2 years (41%), which was greater than the preoperative percentage (21%). Patients accumulated their activity performing light activities; however, patients performed less light activity at 2 years compared with preoperative levels. No significant differences (p = 0.935) were observed for moderate or vigorous activity across time. Conclusions: Together with improvements in self-reported pain and perceived physical function, patients had significantly improved gait function postoperatively. However, despite the opportunity for patients to be more physically active postoperatively, patients were more sedentary, slept worse, and performed less physical activity at 2 years compared with preoperative levels. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
13 May 2020 in Journal of Orthopaedic Research