28 June 2011 in Annals of Pharmacotherapy
Objective: To report 2 cases in which point-of-care international normalized ratios (INRs) in dabigatran-treated patients were inaccurate. Case Summary: A 59-year-old woman with paroxysmal atrial fibrillation was started on warfarin. After 3 days, warfarin was discontinued, and the decision was made to switch to dabigatran 150 mg twice a day, which was started 2 days after the warfarin was discontinued. As treatment was being converted from warfarin to dabigatran therapy, the woman's primary care physician referred her to our anticoagulation clinic, where her point-of-care INR was 7.2. A laboratory INR performed approximately 30 minutes later was 1.7. Several repeat point-of-care INRs were elevated and discordant with the laboratory INRs. A second patient, a 52-year-old man, was started on dabigatran after an ablation procedure, as a bridge to warfarin. Approximately 16 hours after a single dose of dabigatran etexilate 150 mg, the point-of-care INR was 1.6. Discussion: Dabigatran etexilate is an oral direct thrombin inhibitor that is approved for use in thromboprophylaxis of atrial fibrillation and deep vein thrombosis. Dabigatran's predictable pharmacokinetic profile allows for a fixed-dose regimen without the need for coagulation monitoring. In certain clinical situations (eg, switching treatment between dabigatran and warfarin), INR testing is performed as part of routine clinical care. During the development program for dabigatran, laboratory testing of INR was performed, with INRs at therapeutic concentrations of dabigatran ranging from 1.1 to 1.7. Supratherapeutic concentrations of dabigatran elevated the INR to slightly higher levels, between 1.7 and 2.4. Even at extremely high dabigatran concentrations, the INR was generally in the range of 2.3-3.5. Conclusions: We advocate laboratory INR testing with simultaneous assessment of the activated partial thromboplastin time in patients who are receiving or who have recently received dabigatran. A prospective evaluation assessing the accuracy of the commonly used point-of-care INR devices in patients receiving dabigatran would confirm our findings with respect to this device and determine whether our findings extend to other commonly used devices.
11 August 2022 in The American Journal of Cardiology
1 July 2010 in Journal of Clinical Lipidology
23 April 2013 in Cholesterol
Objective. To determine if non-HDL cholesterol (N-HDL) and directly measured LDL cholesterol (D-LDL) are clinically equivalent measurements. Patients and Methods. Eighty-one subjects recruited for 2 cholesterol treatment studies had at least 1 complete fasting lipid panel and D-LDL performed simultaneously; 64 had a second assessment after 4 to 6 weeks, resulting in 145 triads of C-LDL, D-LDL, and N-HDL. To directly compare N-HDL to D-LDL and C-LDL, we normalized the N-HDL by subtracting 30 from the N-HDL (N-HDLA). Results. There was significant correlation between N-HDLA, D-LDL, and C-LDL. Correlation was significantly greater between N-HDLA and C-LDL than between N-HDLA and D-LDL. A greater than 20 mg/dL difference between measures was observed more commonly between N-HDLA and D-LDL, 29%, than between C-LDL and N-HDLA, 11% (), and C-LDL and D-LDL, 17% (). Clinical discordance was most common, and concordance was least common between N-HDL and D-LDL. Conclusions. Our findings suggest that N-HDL cholesterol and D-LDL cholesterol are not clinically equivalent and frequently discordant. As N-HDL may be superior to even C-LDL for predicting events in statin-treated patients, utilizing N-HDL to guide therapy would appear to be preferable to D-LDL when C-LDL is inaccurate.
13 March 2013 in Postgraduate Medicine
Novel oral anticoagulants, direct thrombin inhibitors, and factor Xa inhibitors are being introduced into clinical practice. In contrast to vitamin K antagonists, such as warfarin, these novel agents, because of their relatively wide therapeutic range and predictable pharmacokinetics, have been evaluated in clinical trials and approved for clinical use without the need for routine coagulation monitoring. On occasion, it will be important to assess the anticoagulant status of patients treated with these agents. As a result of their targeted mechanisms of action, they affect standard coagulation assays differently than vitamin K antagonists and heparins, and such assay results may not provide clinically useful information. Thus, less commonly used coagulation assays (eg, chromogenic anti-factor Xa activity assays, diluted thrombin time, and ecarin-based clotting tests) may be introduced into clinical practice. These assays are currently limited by the absence of validated therapeutic targets and lack of standardization across laboratories, vendors, and medication classes. This article provides an overview of the coagulation assays and their potential role in determining the anticoagulant status of patients treated with the emerging anticoagulants.