Massimiliano Solazzi

Massimiliano Solazzi

Auto-generated profile, based on publicly available information

Massimiliano Solazzi

Scuola Superiore SantAnna, IIM Institute, PERCRO Laboratory, Italy

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2018 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
Ilaria BortoneIlaria Bortone
Ilaria Bortone
Daniele LeonardisDaniele Leonardis
Daniele Leonardis
NMNicola Mastronicola
Nicola Mastronicola
ACAlessandra Crecchi
Alessandra Crecchi
LBLuca Bonfiglio
Luca Bonfiglio
Antonio FrisoliAntonio Frisoli
Antonio Frisoli
The past decade has seen the emergence of rehabilitation treatments using Virtual Reality (VR) environments, although translation into clinical practice has been limited so far. In this paper an immersive virtual reality rehabilitation training system endowed with wearable haptics is proposed for children with neuromotor impairments: it aims to enhance involvement and engagement of patients, to provide congruent multi-sensory afferent feedback during motor exercises and to benefit from the flexibility of VR in adapting exercises to the patient’s need. An experimental rehabilitation session conducted with children with Cerebral Palsy (CP) and Developmental Dyspraxia (DD) has been performed to evaluate the usability of the system and proof of concept trial of the proposed approach. We compared CP/DD performance with both Typically Developing (TD) children and ADult (AD) control group. Results show the system was compliant with different levels of motor skills and allowed patients to complete the experimental rehabilitation session, with performance varying according to the expected motor abilities of the different groups. Moreover, a kinematic assessment based on the presented system has been designed. Obtained results reflected the different motor abilities of patients and participants, suggesting suitability of the proposed kinematic assessment as a motor function outcome.

22 October 2019 in IEEE Robotics & Automation Magazine
Verified
Journal Article
Closed access
TKTobias Klamt
Tobias Klamt
MKMalgorzata Kamedula
Malgorzata Kamedula
HKHakan Karaoguz
Hakan Karaoguz
NKNavvab Kashiri
Navvab Kashiri
ALArturo Laurenzi
Arturo Laurenzi
KHKarl Holmquist
Karl Holmquist

19 February 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
MGMassimiliano Gabardi
Massimiliano Gabardi
MSMassimiliano Solazzi
Massimiliano Solazzi
Daniele LeonardisDaniele Leonardis
Daniele Leonardis
Antonio FrisoliAntonio Frisoli
Antonio Frisoli
This letter presents the design of a new exoskeleton for thumb. The main feature of this device is a high degree of underactuation. In fact, the five degrees of freedom (dof) of the thumb are actuated by just one linear actuator. Other features of the thumb-exos are its capability of exert only forces normal to the phalanx axis in the contact point, and its adaptability to different finger sizes. In this letter, the spatial kinematic model is described and the link lengths are determined by means of a genetic algorithm (GA) over four basic grasping poses and the open hand pose. Finally, the thumb-exos mechanism was implemented and integrated in a full hand exoskeleton device. Performance of the thumb exoskeleton in terms of adaptation to different objects and hand sizes, and in terms of grasping forces have been evaluated through experiments and measuring muscular activity, grasping pressure and forces at different locations of the mechanism.

25 January 2021 in IEEE Robotics & Automation Magazine
Verified
Journal Article
Closed access
LTLuca Tiseni
Luca Tiseni
DCDomenico Chiaradia
Domenico Chiaradia
MGMassimiliano Gabardi
Massimiliano Gabardi
MSMassimiliano Solazzi
Massimiliano Solazzi
Daniele LeonardisDaniele Leonardis
Daniele Leonardis
AFAntonio Frisoli
Antonio Frisoli

23 April 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
CCCristian Camardella
Cristian Camardella
FPFrancesco Porcini
Francesco Porcini
AFAlessandro Filippeschi
Alessandro Filippeschi
SMSimone Marcheschi
Simone Marcheschi
MSMassimiliano Solazzi
Massimiliano Solazzi
AFAntonio Frisoli
Antonio Frisoli
A major challenge in the design and control of exoskeletons is the preservation of the user.s natural behavior when interacting with these machines. From this point of view, one of the most important features is the transparency of the exoskeleton. An ideally transparent exoskeleton follows the user's movements without interaction forces. This is the goal of many control algorithms proposed in the literature. Traditional algorithms are based on finite state machines and are affected by assistive torque discontinuity problems in the transitions between phases. State-of-the-art methods approach this problem by imposing a smooth transition that does not account for variable walking speed. In this work, the authors propose an innovative control algorithm for a lower-limb exoskeleton. The proposed control aims at solving the torque discontinuity problem, without requiring a smooth transitions strategy. The proposed control algorithm continuously blends the output of two independent single stance dynamic models, by weighting the contribution of each stance model to the total assistance based on the gait phase. A linear regressor is used to produce the weights, and it requires a brief user-specific calibration. Results showed a significant reduction of interaction forces, and a longer stride length when compared to two finite-state-machine-based controls at two speeds on the treadmill and one self-selected-speed in an overground walk.

1 March 2019 in Robotica
Verified
Journal Article
Closed access
PDF file
Domenico BuongiornoDomenico Buongiorno
Domenico Buongiorno
DCDomenico Chiaradia
Domenico Chiaradia
SMSimone Marcheschi
Simone Marcheschi
MSMassimiliano Solazzi
Massimiliano Solazzi
Antonio FrisoliAntonio Frisoli
Antonio Frisoli
Summary: It is well known that the sense of presence in a tele-robot system for both home-based tele-rehabilitation and rescue operations is enhanced by haptic feedback. Beyond several advantages, in the presence of communication delay haptic feedback can lead to an unstable teleoperation system. During the last decades, several control techniques have been proposed to ensure a good trade-off between transparency and stability in bilateral teleoperation systems under time delays. These proposed control approaches have been extensively tested with teleoperation systems based on identical master and slave robots having few degrees of freedom (DoF). However, a small number of DoFs cannot ensure both an effective restoration of the multi-joint coordination in tele-rehabilitation and an adequate dexterity during manipulation tasks in rescue scenario. Thus, a deep understanding of the applicability of such control techniques on a real bilateral teleoperation setup is needed. In this work, we investigated the behavior of the time-domain passivity approach (TDPA) applied on an asymmetrical teleoperator system composed by a 5-DoFs impedance designed upper-limb exoskeleton and a 4-DoFs admittance designed anthropomorphic robot. The conceived teleoperation architecture is based on a velocity–force (measured) architecture with position drift compensation and has been tested with a representative set of tasks under communication delay (80 ms round-trip). The results have shown that the TDPA is suitable for a multi-DoFs asymmetrical setup composed by two isomorphic haptic interfaces characterized by different mechanical features. The stability of the teleoperator has been proved during several (1) high-force contacts against stiff wall that involve more Cartesian axes simultaneously, (2) continuous contacts with a stiff edge tests, (3) heavy-load handling tests while following a predefined path and (4) high-force contacts against stiff wall while handling a load. The found results demonstrated that the TDPA could be used in several teleoperation scenarios like home-based tele-rehabilitation and rescue operations.