Shumin Lin

Shumin Lin

Auto-generated profile, based on publicly available information

Shumin Lin

Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding 071002, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2024 in Food Bioscience
Verified
Journal Article
Closed access
SLShumin Lin
Shumin Lin
XZXinxia Zhang
Xinxia Zhang
JWJunren Wang
Junren Wang
TLTing Li
Ting Li
Li WangLi Wang
Li Wang

19 October 2021 in The Analyst
Verified
Journal Article
Closed access
PDF file
SLShumin Lin
Shumin Lin
ZZZhe Zhao
Zhe Zhao
YLYun-Kai Lv
Yun-Kai Lv
SSShigang Shen
Shigang Shen
SLShu-xuan Liang
Shu-xuan Liang
The latest research on porous organic frameworks, as well as their multifunctional composites in the sample pretreatment for pesticide and veterinary drug residues, were comprehensively reviewed.

12 August 2024 in Foods
Verified
Journal Article
Open access
PDF file
ZYZhendong Yu
Zhendong Yu
TXTiantian Xu
Tiantian Xu
SLShumin Lin
Shumin Lin
SLShu-xuan Liang
Shu-xuan Liang
In this study, a magnetic porous polymer composite with both hydrophilic and hydrophobic groups was synthesized for magnetic solid phase extraction (MSPE) of milk substrates. Optimization was conducted on various parameters, including adsorption dose, solution pH, adsorption time, and some elution conditions. Coupled with a high-performance liquid chromatography fluorescence detector, a novel MSPE method for determination of norfloxacin (NFX), ciprofloxacin (CIP), and enrofloxacin (ENR) in milk was developed based on magnetic metal organic framework polystyrene polymer (Fe3O4@MOF@PLS) as adsorbent. The Fe3O4@MOF@PLS exhibited significantly improved adsorption performance compared to MOF and PLS. Under optimized experimental conditions, the method exhibited good linearity for the three fluoroquinolones (FQs) in the range of 0.5–1000 μg/kg, with limit of detections (LODs) ranging from 0.21 to 1.33 μg/kg, and limit of quantitations (LOQs) from 0.71 to 4.42 μg/kg. The relative standard deviation (RSD) for the three FQs were 3.4–8.8%. The recoveries of three FQs in milk samples ranged from 84.2% to 106.2%. This method was successfully applied to the detection of three FQs in 20 types of milk, demonstrating its simplicity, speed, and effectiveness in analyte enrichment and separation. The method presented advantages in adsorbent dosage, adsorption time, LODs, and LOQs, making it valuable for the analysis and detection of FQs in milk.

9 July 2021 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
SLShumin Lin
Shumin Lin
JDJiang Xue Dong
Jiang Xue Dong
BZBangwen Zhang
Bangwen Zhang
ZYZeming Yuan
Zeming Yuan
CLChunxiao Lu
Chunxiao Lu
LWLi Wang
Li Wang
A bifunctional fluorescent nanohybrids sensor is designed to realize the simultaneous detection of Fe3+ and Tb3+ in the same solution.