Xun Liu

Xun Liu

Auto-generated profile, based on publicly available information

Xun Liu

Engineering, King's College London - Strand Campus, 4616 London, London United Kingdom of Great Britain and Northern Ireland WC2R 2LS

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2019 in Proceedings of the IEEE
Verified
Journal Article
Open access
OHOliver Holland
Oliver Holland
ESEckehard Steinbach
Eckehard Steinbach
R Venkatesha PrasadR Venkatesha Prasad
R Venkatesha Prasad
QLQian Liu
Qian Liu
ZDZaher Dawy
Zaher Dawy
JAJose Araujo
Jose Araujo
The IEEE ``Tactile Internet'' (TI) Standards working group (WG), designated the numbering IEEE 1918.1, undertakes pioneering work on the development of standards for the TI. This paper describes the WG, its intentions, and its developing baseline standard and the associated reasoning behind that and touches on a further standard already initiated under its scope: IEEE 1918.1.1 on ``Haptic Codecs for the TI.'' IEEE 1918.1 and its baseline standard aim to set the framework and act as the foundations for the TI, thereby also serving as a basis for further standards developed on TI within the WG. This paper discusses the aspects of the framework such as its created TI architecture, including the elements, functions, interfaces, and other considerations therein, as well as the novel aspects and differentiating factors compared with, e.g., 5G Ultra-Reliable Low-Latency Communication, where it is noted that the TI will likely operate as an overlay on other networks or combinations of networks. Key foundations of the WG and its baseline standard are also highlighted, including the intended use cases and associated requirements that the standard must serve, and the TI's fundamental definition and assumptions as understood by the WG, among other aspects.

24 September 2018 in Proceedings of the IEEE
Verified
Journal Article
Closed access
ESEckehard Steinbach
Eckehard Steinbach
MSMatti Strese
Matti Strese
MEMohamad Eid
Mohamad Eid
XLXun Liu
Xun Liu
ABAmit Bhardwaj
Amit Bhardwaj
OHOliver Holland
Oliver Holland
The Tactile Internet will enable users to physically explore remote environments and to make their skills available across distances. An important technological aspect in this context is the acquisition, compression, transmission, and display of haptic information. In this paper, we present the fundamentals and state of the art in haptic codec design for the Tactile Internet. The discussion covers both kinesthetic data reduction and tactile signal compression approaches. We put a special focus on how limitations of the human haptic perception system can be exploited for efficient perceptual coding of kinesthetic and tactile information. Further aspects addressed in this paper are the multiplexing of audio and video with haptic information and the quality evaluation of haptic communication solutions. Finally, we describe the current status of the ongoing IEEE standardization activity P1918.1.1 which has the ambition to standardize the first set of codecs for kinesthetic and tactile information exchange across communication networks.

20 August 2019 in IEEE Transactions on Multimedia
Verified
Journal Article
Closed access
XLXun Liu
Xun Liu
MDMischa Dohler
Mischa Dohler
Yansha DengYansha Deng
Yansha Deng
The emerging mulsemedia (MULtiple SEnsorial MEDIA) introduces new sensorial data (haptic, olfaction, gustation, etc.), significantly augmenting the conventional audio-visual communication. This can be used in many areas, such as immersive entertainment and innovative education. Previous research has been dedicated to evaluating the impact of other sensorial data on conventional multimedia; however, standalone quality evaluation of new sensorial data, especially vibrotactile data (a type of haptic data), has not been covered. To the best of our knowledge, this paper is the first to empirically demonstrate that the common statistical metrics in audio and visual domains, i.e. signal-to-noise ratio (SNR) and Structural SIMilarity (SSIM), are highly correlated with human vibrotactile perception as well. To be specific, we propose a testing protocol for vibrotactile quality evaluation and conduct subjective experiments. The results suggest that SNR and SSIM are applicable to vibrotactile quality assessment. We also consider a practical scenario where the quality of vibrotactile data varies with time. Based on the validation of SNR and SSIM in the first part, we present an objective metric as a hybrid composition of SNR and SSIM. Instead of assessing the quality of data using an overall score, the hybrid metric evaluates the quality in a time-varying manner. Subjective experiments are conducted and the results demonstrate that the correlation coefficient can be significantly increased using the hybrid metric.

1 June 2017
Verified
Conference Paper
Open access
XLXun Liu
Xun Liu
MDMischa Dohler
Mischa Dohler
TMTotam Mahmoodi
Totam Mahmoodi
HLHongbin Liu
Hongbin Liu
Haptic communications allow physical interaction over long distances and greatly complement conventional means of communications, such as audio and video. However, whilst standardized codecs for video and audio are well established, there is a lack of standardized codecs for haptics. This causes vendor lock-in and thereby greatly limits scalability, increases cost and prevents advanced usage scenarios with multi-sensors/actuators and multi-users. The aim of this paper is to introduce a new approach for understanding and encoding tactile signals, i.e. the sense of touch, among haptic interactions. Inspired by various audio codecs, we develop a similar methodology for tactile codecs. Notably, we demonstrate that tactile and audio signals are similar in both time and frequency domains, thereby allowing audio coding techniques to be adapted to tactile codecs with appropriate adjustments. We also present the differences between audio and tactile signals that should be considered in future designs. Moreover, in order to evaluate the performance of a tactile codec, we propose a potential direction of designing an objective quality metric which complements haptic mean opinion scores (h-MOS). This, we hope, will open the door for designing and assessing tactile codecs.

25 June 2020 in IEEE Transactions on Haptics
Verified
Journal Article
Closed access
XLXun Liu
Xun Liu
MDMischa Dohler
Mischa Dohler
Although many tactual communication methods have been developed over the past decades, few of them have been widely adopted in everyday lives. In this paper, we investigate the ability to deliver text messages using patterns of vibrations. By manipulating the duration and frequency of vibrations, we designed two vibrotactile alphabets, i.e. 3F Vibraille and 2F Vibraille, along with their corresponding numbers and symbols. The main difference between 3F Vibraille and 2F Vibraille is the number of frequency levels utilised. Both alphabets were evaluated through human experiments in terms of training time, learning process and recognition accuracy of words and symbols. For both alphabets, the results demonstrated that participants were able to recognise words and symbols at an accuracy of over 90% after 6-8 hours of training. The main difference between the alphabets was that 3F Vibraille achieved a higher transmission rate while 2F Vibraille required less training time.