Zixu Wang

Zixu Wang

Auto-generated profile, based on publicly available information

Zixu Wang

Department of Electronic and Electrical Engineering, Southern University of Science and Technology, Shenzhen, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 March 2021 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
ZWZixu Wang
Zixu Wang
SGShuoxin Gu
Shuoxin Gu
JGJian Guo
Jian Guo
QFQiang Fu
Qiang Fu
LZLingling Zheng
Lingling Zheng
TTTakashi Tamiya
Takashi Tamiya
In this article, we propose a novel magnetic-actuated multimodule drug sustained-release minirobot (DSM) manipulated by an external rotating electromagnetic field. The structure of the DSM is mainly divided into three parts: 1) a shell; 2) an internal propeller; and 3) a drug chamber. The shell can effectively protect the intestinal tract and reduce the various resistances during the work; the built-in propeller not only realizes active locomotion but also saves internal space, which provides the feasibility for the development of functional modules of the robot. The drug chamber pushes the carried drugs out of the chamber similar to a syringe. With structural optimization, we have realized the sustained-release and quantitative drug delivery based on the characteristics of minimagnets’ individual starting frequency- and pitch-related calculations. The main challenge to achieve these functions is to manipulate two magnets in the same magnetic field to drive different functional modules, without mutual interference between the two magnets. In this article, a series of simulations and experiments are conducted to evaluate DSM's motion performance, drug delivery function, and dose control during drug delivery. In the experiment, two different drug delivery points were set up to make DSM spray the drug on the fester areas twice respectively. Finally, an in vitro experiment using the DSM prototype was executed with fresh pig large intestine in a curved shape pipe mold.

10 February 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LZLingling Zheng
Lingling Zheng
SGShuoxin Gu
Shuoxin Gu
ZWZixu Wang
Zixu Wang
TTTakashi Tamiya
Takashi Tamiya
This paper proposes a main-functional module working concept for capsule robots, and the capsule robots consist of a main module and functional modules based on this concept. The main module drives the functional modules and provides guidance and support for the functional modules while the functional modules perform the specific diagnosis or treatment. In addition, we propose a novel single-function design concept, which enables different functional modules to have different functions according to the medical requirements. The diagnosis and treatment functions are separated, and they will allow each module to work more specifically and efficiently. Various functional modules can be selected according to medical requirements, and thus it can improve treatment efficiency and reduce medical costs. The single-function design concept eliminates the need to integrate multiple functions into one robot and decrease manufacturing difficulty. Besides, we present a novel docking-separation method to realize effective docking and rapid separation for capsule robots. It can also enable the docked robot to work in bent parts of intestinal tracts easily. A multimodule capsule robot (MCR) was fabricated and the performance was evaluated through experiments. Experimental results demonstrated that the robot modules could be controlled independently and could dock reliably and separate easily. Moreover, the MCR can prevent accidental separation and has potential applications in the clinical practices of intestinal tracts.

24 November 2025 in Sensors
Verified
Journal Article
Open access
PDF file
LZLingling Zheng
Lingling Zheng
JSJie Sun
Jie Sun
ZQZhengdong Qi
Zhengdong Qi
LYLe Yan
Le Yan
FZFen Zhao
Fen Zhao
SGShuoxin Gu
Shuoxin Gu
Magnetically controlled capsule robots offer unique advantages for performing intestinal biopsies. In this paper, we propose a novel Magnetically Controlled Capsule Robot for Intestinal Biopsy (MCCR-IB), capable of both navigation and biopsy within the intestine. To address the coupling issue between locomotion control and biopsy control, a magnetic field locking method is also introduced. The locomotion performance, curved-passage capability, and biopsy ability were experimentally evaluated. Under a 7 Hz rotating magnetic field, the MCCR-IB achieved forward and backward velocities of 20.22 mm/s and 18.27 mm/s, respectively, with a biopsy needle puncture force of 1.99 N. Furthermore, ex vivo experiments were conducted to preliminarily verify the feasibility of the robot’s motion and biopsy functions. The experimental results demonstrate that the proposed MCCR-IB exhibits good performance and shows promising potential for future clinical applications.

24 November 2025 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
PLPengcheng Li
Pengcheng Li
SGShuoxin Gu
Shuoxin Gu
JLJun Leng
Jun Leng
ZWZixu Wang
Zixu Wang
This paper presents a portable, cable-driven upper-limb rehabilitation robot designed for home-based activities of daily living (ADLs). The proposed robot is intended to assist hemiplegia patients with ADL-based rehabilitation, such as drinking water from a cup, in home settings. The robot features a rehabilitation control framework based on dynamic movement primitives (DMPs) that personalizes spatial profiles from healthy-limb demonstrations. It modulates movement velocity and inter-joint coordination online via human–robot interaction. The system was evaluated in a drinking task with ten healthy participants. Compared with a classic (non-adaptive) DMP controller, the proposed robot increased voluntary participation (EMG amplitude: +64.71%) and reduced robotic assistance (assistance force: -56.10%), while also improving inter-joint coordination. These results indicate that the proposed system supports personalized, task-specific assistance and holds promise for home-based upper-limb rehabilitation.

15 May 2026 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
MSMiaozhang Shen
Miaozhang Shen
SGShuoxin Gu
Shuoxin Gu
ZWZixu Wang
Zixu Wang
YYYuyue Yang
Yuyue Yang
CLChunying Li
Chunying Li
BWBing Wang
Bing Wang
Real-time localization is a requirement for the clinical application of magnetically actuated wireless capsule endoscopy. This study proposes a physics-informed deep learning framework to address the model-plant mismatch inherent in analytical methods and the data requirements of end-to-end learning. A dual-branch residual network, physics-informed residual network, computes corrections for the magnetic dipole model. Two operational paradigms are evaluated: a lookup-table-based approach and an end-to-end optimization approach. Experiments indicate that the framework achieves a mean position error of 0.69 $\pm$ 0.29 mm and a mean orientation error of 0.70 $\pm$ 0.37$^{\circ }$, utilizing less than 20% of the calibration configurations required by data-driven baselines. Validation includes an ex vivo signal propagation study through biological tissue and compatibility tests with an anti-interference filter, supplemented by a preliminary in vivo animal experiment. The results provide a methodology for sim-to-real transfer in robotic capsule tracking systems.

26 March 2026 in Measurement
Verified
Journal Article
Closed access
CLChunying Li
Chunying Li
SGShuxiang Guo
Shuxiang Guo
LHLe Huang
Le Huang
ZWZixu Wang
Zixu Wang
PLPengcheng Li
Pengcheng Li