Srdjan Z. Dragovic

Srdjan Z. Dragovic

Auto-generated profile, based on publicly available information

Srdjan Z. Dragovic

Department of Anesthesiology and Intensive Care TUM School of Medicine and Health , Technical University of Munich, Munich, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2023 in Anesthesiology
Verified
Journal Article
Closed access
PDF file
SDSrdjan Dragovic
Srdjan Dragovic
GSGerhard Schneider
Gerhard Schneider
PGPaul S. García
Paul S. García
DHDominik Hinzmann
Dominik Hinzmann
JSJamie Sleigh
Jamie Sleigh
MKMatthias Kreuzer
Matthias Kreuzer
Background: Processed electroencephalography (EEG) is used to monitor the level of anesthesia, and it has shown the potential to predict the occurrence of delirium. While emergence trajectories of relative EEG band power identified post hoc show promising results in predicting a risk for a delirium, they are not easily transferable into an online predictive application. This article describes a low-resource and easily applicable method to differentiate between patients at high risk and low risk for delirium, with patients at low risk expected to show decreasing EEG power during emergence. Methods: This study includes data from 169 patients (median age, 61 yr [49, 73]) who underwent surgery with general anesthesia maintained with propofol, sevoflurane, or desflurane. The data were derived from a previously published study. The investigators chose a single frontal channel, calculated the total and spectral band power from the EEG and calculated a linear regression model to observe the parameters’ change during anesthesia emergence, described as slope. The slope of total power and single band power was correlated with the occurrence of delirium. Results: Of 169 patients, 32 (19%) showed delirium. Patients whose total EEG power diminished the most during emergence were less likely to screen positive for delirium in the postanesthesia care unit. A positive slope in total power and band power evaluated by using a regression model was associated with a higher risk ratio (total, 2.83 [95% CI, 1.46 to 5.51]; alpha/beta band, 7.79 [95% CI, 2.24 to 27.09]) for delirium. Furthermore, a negative slope in multiple bands during emergence was specific for patients without delirium and allowed definition of a test for patients at low risk. Conclusions: This study developed an easily applicable exploratory method to analyze a single frontal EEG channel and to identify patterns specific for patients at low risk for delirium. Editor’s Perspective: What We Already Know about This Topic: What This Article Tells Us That Is New:

21 April 2025 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
SSStefan Schwerin
Stefan Schwerin
SDSrdjan Z. Dragovic
Srdjan Z. Dragovic
JOJulian Ostertag
Julian Ostertag
DNDuy-Minh Nguyen
Duy-Minh Nguyen
GSGerhard Schneider
Gerhard Schneider
MKMatthias Kreuzer
Matthias Kreuzer
Patients with dementia face increased risks after general anesthesia. Improved perioperative electroencephalogram (EEG) monitoring techniques could aid in identifying vulnerable patients. However, current technology relies on processed indices to measure “depth-of-anesthesia”. Analyzing OpenNeuro Dataset ds004504, we compared resting-state, eyes-closed EEG recordings of healthy controls (n = 27) with patients diagnosed with Alzheimer’s disease (AD, n = 35) and Frontotemporal dementia (FTD, n = 23). We focused on prefrontal recordings. Analysis included spectral analysis, the “fitting-oscillations&-one-over-f”-algorithm for aperiodic and periodic signal features, as well as calculations of openibis, permutation entropy (PeEn), spectral entropy (SpEn), and spectral edge frequency (SEF). Spectral differences were pronounced, including a higher alpha/theta-ratio of controls (2.62 [95%CI: 1.54–3.62]) compared to both AD (0.55 [95%CI: 0.26–1.92], P < 0.001, AUC: 0.765 [0.642–0.888]) and FTD (0.83 [95%CI: 0.33–1.65], P = 0.007, AUC: 0.779 [0.652–0.907]). Oscillatory peak detection within the alpha frequency band was more robust in control (versus AD: P = 0.003, Cramér’s V = 0.374; versus FTD: P = 0.003, Cramér’s V = 0.414). Processed index parameters did not show a clear trend. FTD was associated with a higher prefrontal openibis (95.53 [95%CI: 93.43–97.39]) than control (91.98 [95%CI: 89.46–96.27], P = 0.033, AUC: 0.717 [0.572–0.862]) and an elevated SEF (23.68 [95%CI: 14.10–25.57] Hz) compared to AD (16.60 [95%CI: 14.22–22.22] Hz, P = 0.041, AUC: 0.676 [0.532–0.821]). AD and FTD are associated with EEG baseline abnormalities, and a standard prefrontal montage, as used intraoperatively, could present a promising technical screening approach for cognitive vulnerability. However, these EEG features are obscured by processed index parameters currently used in neuroanesthesia monitoring. OpenNeuro Dataset ds004504 “A dataset of EEG recordings from: Alzheimer’s disease, Frontotemporal dementia and Healthy subjects” (doi:https://doi.org/10.18112/openneuro.ds004504.v1.0.7).

17 December 2024 in NeuroImage
Verified
Journal Article
Open access
SZSebastian Zinn
Sebastian Zinn
SDSrdjan Z. Dragovic
Srdjan Z. Dragovic
JKJan A. Kloka
Jan A. Kloka
LWLaurent M. Willems
Laurent M. Willems
SHSebastian Harder
Sebastian Harder
MKMatthias Kreuzer
Matthias Kreuzer
Cortical high-frequency activation immediately before death has been reported, raising questions about an enhanced conscious state at this critical time. Here, we analyzed an electroencephalogram (EEG) from a comatose patient during the dying process with a standard bedside monitor and spectral parameterization techniques. We report neurophysiologic features of a dying patient without major cortical injury. Sixty minutes of frontal EEG activity was recorded using the Sedline™ monitor. Quantitative metrics of the frequency spectrum, the non-oscillatory 1/f characteristic, and signal complexity with Lemple-Ziv-Welch and permutation entropy were calculated. In addition to comparing the EEG trajectories over time, we provide a comparison to EEG records obtained from other studies with well-known vigilance states (sleep, anesthesia, and wake). Although we observed changes in high-frequency activation during the dying process, larger alterations of the aperiodic EEG components were also noted. These changes differed dramatically when compared to EEG records representative of wake, slow-wave sleep, or anesthesia. Although still fundamentally unique, the neuronal activity present in the dying brain is more similar to REM sleep than any other state we tested. Even in patients with coma, temporal dynamics in quantitative EEG features (including the aperiodic components) can be observed in the final hour before death.

5 September 2025 in Journal of Clinical Monitoring and Computing
Verified
Journal Article
Open access
PDF file
SSStefan Schwerin
Stefan Schwerin
SDSrdjan Z. Dragovic
Srdjan Z. Dragovic
JOJulian Ostertag
Julian Ostertag
DNDuy-Minh Nguyen
Duy-Minh Nguyen
GSGerhard Schneider
Gerhard Schneider
MKMatthias Kreuzer
Matthias Kreuzer