10 September 2020 in IEEE Transactions on Instrumentation and Measurement
In this paper, the fault diagnosis problem for power converters is considered. Given that the existing fault diagnosis models rarely address the problems of the data noise and the new faults that are never emerged in the database, thus, an optimized fault diagnosis model for power converters based on temporal convolutional network (TCN) is proposed. Our contributions include: 1) unknown faults can be efficiently distinguished with an optimized classifier; 2) the proposed model has good robustness and reliability under noisy environment without any subsidiary pre-denoising algorithm; 3) it can realize adaptive feature extraction, and the parameters are small. Experimental results on a three-phase voltage inverter platform demonstrate that the proposed approach is efficient and can be adaptively applied to various real applications.
16 June 2022 in IEEE Transactions on Instrumentation and Measurement
Dual-active-bridge (DAB) converter can connect several ac distribution networks with different voltage levels by a common dc bus to form ac/dc hybrid distribution networks. Its reliability issue has become a hot research topic in academia and industry. In this article, the fault operation mode of DAB is analyzed in detail, and a fault diagnosis strategy based on adaptive threshold denoising for residual networks is proposed on this basis. The main module of the diagnosis algorithm consists of an improved channel attention module and threshold algorithm. The improved channel attention module improves the network’s ability to learn features by using two ways to extract different features of the fault signal separately. The threshold algorithm is embedded into the deep network as a nonlinear layer. The thresholds can be learned adaptively in the established cells, which plays a good adaptive denoising capability. Finally, by building a hardware-in-the-loop system, we compare the signal denoising ability of various methods at different signal-to-noise ratios. The experimental results demonstrate that the proposed method can accurately locate the open-circuit fault and achieve 99.82% accuracy under the original data. It is also more accurate than other methods under different signal-to-noise ratios, which verifies the correctness and effectiveness of the method.
19 August 2019 in IEEE Transactions on Industry Applications
High quality online uninterruptible power supplies (UPS) are widely used in applications e.g. precision medical equipment with critical loads. This paper proposes a low-cost and high performance online UPS system. Firstly, the performance improvement of a bidirectional switch based bridgeless power factor (PFC) converter, which is regulated by a hybrid control strategy with load current feedforward is studied. Secondly, the proposed closed-loop controller integrates the improved predictive current control with predictive voltage control and thereby it applies to the second-stage neutral-point-clamped (NPC) three-level inverter to reduce harmonics of the output ac voltage. Moreover, a push-pull DC-DC converter to boost the voltage as the backup energy source interfaces a 24V battery bank. Considering the complexity of the UPS system as well as cost reduction, we implement a multi-task decomposition method for control on a monolithic low-cost digital signal processor (DSP) embedded with Control Law Accelerator (CLA). Finally, the experimental results from a 1kVA a prototype can effectively verify validly of the theoretical analysis and design.
31 May 2023 in IEEE Transactions on Automation Science and Engineering
Potential malicious attacks have been a significant security concern for network system applications. However, there are few studies on filtering for hybrid network attacks in switching systems. This paper considers a Kalman filtering problem for the switched systems that suffer from deception attacks and denial-of-service attacks. A new network transmission model for switching systems is established. Then, based on the minimum mean square error criterion, a Kalman filter with low conservatism is designed for the discrete-time switched system. The newly switched Kalman gain matrix is deduced including the random variation of the switching signal after being attacked by the network. Finally, the effectiveness of the proposed filter is verified by the numerical simulation. Note to Practitioners —A switching system is considered to be a typical hybrid system. As it often works in a network environment, the switching signal is vulnerable to the network and thus to various cyber-attacks (e.g. spoofing attacks and denial-of-service attacks). Few studies have been conducted on the impact of switching signals in network transmission. To address this problem, this paper proposes a Kalman filter design method with low conservativeness, which describes network attacks and data loss by building a Kalman filter model associated with the switching signal in terms of satisfying Bernoulli random variables. For practitioners, the ability to recover data to a certain extent when the data transmission is affected by different network attacks will save a lot of costs and is important for improving the stability and performance of switching systems. Our future work will aim to improve the performance of different filtering algorithms under different cyber-attacks.
23 December 2022 in IEEE Transactions on Transportation Electrification
To improve the efficiency of the dual active bridge (DAB) converter working in the low and medium power ranges, this paper proposes a new triple-phase-shift (TPS) modulation scheme based on frequency domain fundamental harmonic analysis (FDFHA) with lower root mean square (RMS) current and wider zero-voltage switching (ZVS) range. The DAB converter’s Fourier decomposition expression under TPS is generated, and the FDFHA expression is created using fundamental harmonic analysis (FHA). With the RMS current as the optimization target, the operating point with the smallest RMS current is found by solving for it using the extended global optimum condition (EGOC) that applies to the FDFHA expression. Based on this, a control strategy with a simple controller structure is established, which has excellent dynamic performance. Additionally, when comparing the proposed scheme to other optimized schemes, the results show that the proposed scheme can drastically lower the RMS current in the low and medium power ranges and achieve a wider ZVS range, notably in the low power range to enable all switches to achieve ZVS. Finally, an experimental prototype with a peak efficiency of 95.95% was built to verify the effectiveness of the proposed scheme.
1 January 2022 in IEEE Control Systems Letters
In this letter, an adaptive dynamic programming (ADP) method is proposed for optimized formation control of second-order linear systems. The method exploits an actor-critic architecture, where an actor component is used to learn the optimal formation controller, and a critic component is used to learn the optimal value function. Generally, ADP requires a priori knowledge of persistence of excitation (PE) to guarantee the stability of the control system. However, the PE condition is hard to verify during the learning process and in practical applications. To this end, this letter redesigns the updating laws of the actor and critic components to ensure that the Bellman residual error can eventually approach to zero, and the stability of the control system can be guaranteed without introducing the PE and additional constraints. By using Lyapunov stability analysis, we prove that the proposed optimized formation scheme can achieve the desired optimizing performance. Finally, a simulation example is given to demonstrate the effectiveness of the proposed method.