Andrius Baltrušaitis

Andrius Baltrušaitis

Auto-generated profile, based on publicly available information

Andrius Baltrušaitis

Dept of Roads, Vilnius Gediminas Technical University, Vilnius, Lithuania

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2020 in The Baltic Journal of Road and Bridge Engineering
Verified
Journal Article
Open access
PDF file
ABAndrius Baltrušaitis
Andrius Baltrušaitis
AVAudrius Vaitkus
Audrius Vaitkus
JSJuris Smirnovs
Juris Smirnovs
The assurance of asphalt pavement layer compaction, expressed by ratio between field and laboratory bulk density and air voids content, is one of the main criteria of the durability of asphalt road pavement. Destructive measures should be applied and cores should be taken from the asphalt pavement seeking to determine the representative compaction level of the constructed asphalt layers. New methods are constantly being sought for fast, non-destructive and accurate asphalt layer density and air void determination on road. Ground Penetrating Radar (GPR) can allow determining the qualitative characteristics of asphalt pavement across the entire length of the road without causing damage to the road structure. Relative dielectric permittivity, usually called dielectric value or constant, is the leading property used in GPR applications on road pavement surveys. This article presents GPR measurement results from asphalt base and binder layers of four test sections. GPR measurements were conducted immediately after the end of asphalt layer compaction process. Test points on each layer were selected and density, air void content were determined by drilling cores and testing them in the laboratory. To estimate asphalt layer density and air void content, GPR data were analysed using different existing mathematical models. To justify the reliability of the data measured by GPR, results were checked by comparing them with the results measured directly on cores taken from the asphalt pavement layers.

21 June 2021 in The Baltic Journal of Road and Bridge Engineering
Verified
Journal Article
Open access
PDF file
AVAudrius Vaitkus
Audrius Vaitkus
JGJudita Gražulytė
Judita Gražulytė
ABAndrius Baltrušaitis
Andrius Baltrušaitis
JŽJurgita Židanavičiūtė
Jurgita Židanavičiūtė
DČDonatas Čygas
Donatas Čygas
Properly designed and maintained asphalt pavements operate for ten to twenty-five years and have to be rehabilitated after that period. Cold in-place recycling has priority over all other rehabilitation methods since it is done without preheating and transportation of reclaimed asphalt pavement. Multiple researches on the performance of cold recycled mixtures have been done; however, it is unclear how the entire pavement structure (cold recycled asphalt pavement overlaid with asphalt mixture) performs depending on binding agents. The main objective of this research was to evaluate the performance of cold in-place recycled asphalt pavements considering binding agents (foamed bitumen in combination with cement or only cement) and figure out which binder leads to the best pavement performance. Three road sections rehabilitated in 2000, 2003, and 2005 were analysed. The performance of the entire pavement structure was evaluated in terms of the International Roughness Index, rut depth, and pavement surface distress in 2013 and 2017.

28 March 2022 in The Baltic Journal of Road and Bridge Engineering
Verified
Journal Article
Open access
PDF file
ABAndrius Baltrušaitis
Andrius Baltrušaitis
AVAudrius Vaitkus
Audrius Vaitkus
JŽJurgita Židanavičiūtė
Jurgita Židanavičiūtė
Assurance of asphalt pavement layer compaction, expressed by air voids ratio between field and laboratory bulk density, is one of the main criteria of the asphalt pavement durability. Thus, destructive measures should be applied, and many asphalt samples should be taken on site in order to determine the representative compaction level of constructed pavement. With the fast development of technologies, new methods should be considered for fast, non-destructive and accurate determination of asphalt bulk density on site. As there are quite few non-destructive methods related to asphalt pavement density measurement, there is a need to make comparison of such methods. Currently, when GPR methods are used to determine the density, calibration cores are used in all cases to estimate the unknown or unmeasured variables or conditions that may affect the results of dielectric value measurements. The aim of this study is to develop a regression model that can predict the bulk density of the compacted asphalt layer without coring, using the design values of the bulk density determined in the type tests of asphalt mixtures or other currently used non-destructive testing technologies (in this case PQI and NDG) and GPR measured dielectric constant values.