Engineering a layer of nitrogen-vacancy (NV) centers on the tip of a diamond anvil creates a multipurpose quantum sensor array for high-pressure measurements, especially for probing the magnetic and superconducting properties of materials. Expanding this concept above 100 GPa appears to be a substantial challenge. We observe that deviatoric stress on the anvil tip sets a limit at 40–50 GPa for practical magnetic measurements based on the optically detected magnetic resonance (ODMR) of NV centers under pressure. We show that this limit can be circumvented up to at least 130 GPa by machining a micropillar on the anvil tip to create a quasihydrostatic stress environment for the NV centers. Improved hydrostaticity is quantified using the pressure dependence of the diamond Raman shift, the NV ODMR dependence on applied magnetic field, and NV photoluminescence spectral shift. This paves the way for the reliable use of NV microsensing at pressures above 100 GPa.
We investigate the optical properties of silicon-vacancy (SiV) and germanium-vacancy (GeV) color centers in nanodiamonds under hydrostatic pressure up to 180 GPa. The nanodiamonds were synthesized by Si- or Ge-doped plasma-assisted chemical vapor deposition and, for our experiment, pressurized in a diamond anvil cell. Under hydrostatic pressure we observe blueshifts of the SiV and GeV zero-phonon lines by 17 THz (70 meV) and 78 THz (320 meV), respectively. These measured pressure-induced shifts are in good agreement with ab initio calculations that take into account the lattice compression based on the equation of state of diamond and that are extended to the case of the tin-vacancy (SnV) center. This work provides guidance on the use of group-IV-vacancy centers as quantum sensors under extreme pressures that will exploit their specific optical and spin properties induced by their intrinsic inversion-symmetric structure.
We present here a magnetic imaging setup for magnetic thin films, allowing two methods of probing: Magneto-Optical Kerr Effect and Nitrogen-vacancy probing. The first mode allows a quick viewing of the magnetic domains, with a resolution limited by optical diffraction, but does not provide quantitative measurement of the magnetization. This information is obtained by adding the complementary NV imaging mode, which consists of the widefield imaging of an NV-doped diamond plate on top of the magnetic film. We can then image the magnetic domains with high resolution and simultaneously measure the total magnetic moment of the order of 10−15 A m2 from the influence of the stray magnetic field on the NV optically detected magnetic resonance spectrum.
The spatial distribution of a magnetic field can be determined with micrometer resolution using widefield nitrogen vacancy (NV) center magnetic imaging. Nevertheless, reconstructing the magnetic field from the raw data can be challenging due to the degeneracy of the four possible NV axes and the tremendous amount of data. While a qualitative approach is sufficient for most analyses, a quantitative analysis offers deeper insight into the physical system. Here, we apply NV widefield magnetic imaging to a HgBa2Ca2Cu3O8+δ (Hg-1223) superconducting microcrystal at a pressure of 4 GPa. We fit the results with solutions from the Hamiltonian describing the NV center ground state and take into account the relative intensities of the resonances to determine the local magnetic field magnitude and angle. Thus, we reconstruct the temperature-dependent expulsion of the magnetic field associated with the Meissner effect around the superconductor. By comparing the resulting parameters to Brandt's model, which describes the magnetic behavior of a type-II superconductor, we extract the critical current density jc. Overall, this work showcases the first widefield quantitative reconstruction of the field screening under pressure and an optical method to study critical current density. Thus, it provides new insights into the application of NV magnetometry to superconductivity research at high pressures.
Les microscopies optiques super-résolues aident à mieux comprendre certains mécanismes biomoléculaires, notamment au sein des neurones. Nous avons construit un tel microscope de type STED (STimulated Emission Depletion) pour observer des défauts azote-lacune (NV) fluorescents dans le diamant, et avons atteint une résolution de 50 nm. À plus long terme, cet instrument permettra d’étudier l’organisation macromoléculaire de protéines impliquées dans la plasticité synaptique, et marquées avec des nanodiamants (ND) fluorescents. Dans cette perspective, nous avons étudié la limite de résolution du STED pour des ND de tailles sub-longueur d’onde. Nos expériences, menées avec l’équipe de Stefan Hell (Max Planck Institute for Biophysical Chemistry) ont montré que la taille du spot STED d’un NV dans un ND pouvait atteindre 10 nm, performance similaire à celle obtenue dans un diamant macroscopique. Nous pouvons aussi résoudre plusieurs centres NV dans un ND séparés de seulement ~15 nm. Ces résultats sont en accord avec les simulations numériques faites par l’équipe de Jean-Jacques Greffet (Laboratoire Charles Fabry). En parallèle, nous avons démontré l’internalisation spontanée de ND fluorescents dans des neurones corticaux d’embryons de souris en culture primaire, et étudié leur colocalisation avec des vésicules du réseau trans-Golgi. Enfin, nous avons débuté l’étude du trafic des vésicules contenant les ND et montré qu’il dépend du réseau de microtubules. Les paramètres du mouvement sont compatibles avec ceux des moteurs moléculaires, mais nous nous attendons à ce qu’ils soient différents dans le cas de la surexpression de protéines impliquées dans le trafic (travail en cours).