Loïc Toraille

Loïc Toraille

Auto-generated profile, based on publicly available information

Loïc Toraille

CEA, DAM, DIF, F-91297, Arpajon, France.

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2019 in Science
Verified
Journal Article
Closed access
PDF file
MLMargarita Lesik
Margarita Lesik
TPThomas Plisson
Thomas Plisson
LTLoïc Toraille
Loïc Toraille
JRJustine Renaud
Justine Renaud
FOFlorent Occelli
Florent Occelli
JRJean-François Roch
Jean-François Roch
Diamond-based sensors: Material properties can change dramatically under pressure. Typically, to achieve high-pressure conditions, researchers place their samples in diamond anvil cells (DACs). However, monitoring the properties of the sample inside a DAC is tricky (see the Perspective by Hamlin and Zhou). Hsieh et al. , Lesik et al. , and Yip et al. developed monitoring techniques based on nitrogen-vacancy (NV) centers in diamond. The NV centers can act as sensors because their energy levels and the associated spectra are sensitive to strain and magnetic fields. This enabled optical readout of a spatially resolved signal. Science , this issue p. 1349 , p. 1359 , p. 1355 ; see also p. 1312

1 August 2015 in Microelectronics Reliability
Verified
Journal Article
Closed access
ANA. Nowodzinski
A. Nowodzinski
MCMayeul Chipaux
Mayeul Chipaux
LTL. Toraille
L. Toraille
VJV. Jacques
V. Jacques
JRJ.-F. Roch
J.-F. Roch
TDT. Debuisschert
T. Debuisschert

7 December 2015 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
MCMayeul Chipaux
Mayeul Chipaux
LTL. Toraille
L. Toraille
CLC. Larat
C. Larat
LML. Morvan
L. Morvan
SPS. Pezzagna
S. Pezzagna
TDT. Debuisschert
T. Debuisschert
We propose an original analog method to perform instantaneous and quantitative spectral analysis of microwave signals. An ensemble of nitrogen-vacancy (NV) centers held in a diamond plate is pumped by a 532 nm laser. Its photoluminescence is imaged through an optical microscope and monitored by a digital camera. An incoming microwave signal is converted into a microwave field in the area of the NV centers by a loop shaped antenna. The resonances induced by the magnetic component of that field are detected through a decrease of the NV centers photoluminescence. A magnetic field gradient induces a Zeeman shift of the resonances and transforms the frequency information into spatial information, which allows for the simultaneous analysis of the microwave signal in the entire frequency bandwidth of the device. The time dependent spectral analysis of an amplitude modulated microwave signal is demonstrated over a bandwidth of 600 MHz , associated to a frequency resolution of 7 MHz  , and a refresh rate of 4 ms . With such integration time, a field of a few hundreds of μW can be detected. Since the optical properties of NV centers can be maintained even in high magnetic field, we estimate that an optimized device could allow frequency analysis in a range of 30 GHz , only limited by the amplitude of the magnetic field gradient. In addition, an increase of the NV centers quantity could lead both to an increase of the microwave sensitivity and to a decrease of the minimum refresh rate down to a few μs .

1 June 2015 in Diamond and Related Materials
Verified
Journal Article
Closed access
MLM. Lesik
M. Lesik
TPT. Plays
T. Plays
ATA. Tallaire
A. Tallaire
JAJ. Achard
J. Achard
OBO. Brinza
O. Brinza
VJV. Jacques
V. Jacques

13 June 2023 in Physical Review B
Verified
Journal Article
Closed access
PDF file
AHAntoine Hilberer
Antoine Hilberer
LTLoïc Toraille
Loïc Toraille
CDCassandra Dailledouze
Cassandra Dailledouze
MAMarie-Pierre Adam
Marie-Pierre Adam
LHLiam Hanlon
Liam Hanlon
JRJean-François Roch
Jean-François Roch
Engineering a layer of nitrogen-vacancy (NV) centers on the tip of a diamond anvil creates a multipurpose quantum sensor array for high-pressure measurements, especially for probing the magnetic and superconducting properties of materials. Expanding this concept above 100 GPa appears to be a substantial challenge. We observe that deviatoric stress on the anvil tip sets a limit at 40–50 GPa for practical magnetic measurements based on the optically detected magnetic resonance (ODMR) of NV centers under pressure. We show that this limit can be circumvented up to at least 130 GPa by machining a micropillar on the anvil tip to create a quasihydrostatic stress environment for the NV centers. Improved hydrostaticity is quantified using the pressure dependence of the diamond Raman shift, the NV ODMR dependence on applied magnetic field, and NV photoluminescence spectral shift. This paves the way for the reliable use of NV microsensing at pressures above 100 GPa.

1 November 2018 in Nano Letters
Verified
Journal Article
Closed access
LTLoïc Toraille
Loïc Toraille
KAKoceila Aïzel
Koceila Aïzel
ÉBÉlie Balloul
Élie Balloul
CVChiara Vicario
Chiara Vicario
CMCornelia Monzel
Cornelia Monzel
MDMaxime Dahan
Maxime Dahan