3 November 2022 in IEEE Transactions on Medical Imaging
Main coronary segmentation from the X-ray angiography images is important for the computer-aided diagnosis and treatment of coronary disease. However, it confronts the challenge at three different image granularities (the semantic, surrounding, and local levels). The challenge includes the semantic confusion between the main and collateral vessels, low contrast between the foreground vessel and background surroundings, and local ambiguity near the vessel boundaries. The traditional hand-crafted feature-based methods may be insufficient because they may lack the semantic relationship information and may not distinguish the main and collateral vessels. The existing deep learning-based methods seem to have issues due to the deficiency in the long-distance semantic relationship capture, the foreground and background interference adaptability, and the boundary detail information preservation. To solve the main coronary segmentation challenge, we propose the progressive perception learning (PPL) framework to inspect these three different image granularities. Specifically, the PPL contains the context, interference, and boundary perception modules. The context perception is designed to focus on the main coronary vessel based on the semantic dependence capture among different coronary segments. The interference perception is designed to purify the feature maps based on the foreground vessel enhancement and background artifact suppression. The boundary perception is designed to highlight the boundary details based on boundary feature extraction through the intersection between the foreground and background predictions. Extensive experiments on 1085 subjects show that the PPL is effective (e.g., the overall Dice is greater than 95%), and superior to thirteen state-of-the-art coronary segmentation methods.
2 May 2023 in IEEE Journal of Biomedical and Health Informatics
Vessel contour detection (VCD) in intravascular images is important for the quantitative assessment of vessels. However, it is still a challenging task due to a high degree of morphology variability. Images from a single modality lack sufficient information on the vessel morphology due to the natural limitation of the imaging capability. Therefore, the single-modality VCD methods have difficulty extracting sufficient morphological information. Cross-modality methods have the potential to overcome morphology variability by extracting more information from different modalities. However, they still face the difficulty of the domain discrepancy, i.e. feature space discrepancy and label space inconsistency. In this paper, we aims to address this domain discrepancy for VCD. To overcome label space inconsistency, our method divides the label space into private label space and shared label space. It constructs subdomains for the private label space and the shared label space, and then minimizes the task risk at the subdomain level. To overcome feature space discrepancy, it extracts domain-invariant features via domain adaptation between the subdomains. Finally, it uses the domain-invariant features as auxiliary information for each subdomain. Extensive experiments on 130 IVUS sequences (135663 images) and 124 OCT sequences (39857 images) show that our method is effective (e.g., the Dice index $\geqslant$ 0.949), and superior to the nineteen state-of-the-art VCD methods.
9 February 2017 in Hypertension Research
28 November 2022 in IEEE/ACM Transactions on Computational Biology and Bioinformatics
Vessel border detection in IVUS images is essential for coronary disease diagnosis. It helps to obtain the clinical indices on the inner vessel morphology to indicate the stenosis. However, the existing methods suffer the challenge of scale-dependent interference. Early methods usually rely on the hand-crafted features, thus not robust to this interference. The existing deep learning methods are also ineffective to solve this challenge, because these methods aggregate multi-scale features in the top-down way. This aggregation may bring in interference from the non-adjacent scale. Besides, they only combine the features in all scales, and thus may weaken their complementary information. We propose the scale mutualized perception to solve this challenge by considering the adjacent scales mutually to preserve their complementary information. First, the adjacent small scales contain certain semantics to locate different vessel tissues. Then, they can also perceive the global context to assist the representation of the local context in the adjacent large scale, and vice versa. It helps to distinguish the objects with similar local features. Second, the adjacent large scales provide detailed information to refine the vessel boundaries. The experiments show the effectiveness of our method in 153 IVUS sequences, and its superiority to ten state-of-the-art methods.
28 May 2024 in IEEE Transactions on Biomedical Engineering
Objective: Non-invasive computation of the index of microcirculatory resistance from coronary computed tomography angiography (CTA), referred to as IMR $_\text{CT}$ , is a promising approach for quantitative assessment of coronary microvascular dysfunction (CMD). However, the computation of IMR $_\text{CT}$ remains an important unresolved problem due to its high requirement for the accuracy of coronary blood flow. Existing CTA-based methods for estimating coronary blood flow rely on physiological assumption models to indirectly identify, which leads to inadequate personalization of total and vessel-specific flow. Methods: To overcome this challenge, we propose a vascular deformation-based flow estimation (VDFE) model to directly estimate coronary blood flow for reliable IMR $_\text{CT}$ computation. Specifically, we extract the vascular deformation of each vascular segment from multi-phase CTA. The concept of inverse problem solving is applied to implicitly derive coronary blood flow based on the physical constraint relationship between blood flow and vascular deformation. The vascular deformation constraints imposed on each segment within the vascular structure ensure sufficient individualization of coronary blood flow. Results: Experimental studies on 106 vessels collected from 89 subjects demonstrate the validity of our VDFE, achieving an IMR $_\text{CT}$ accuracy of 82.08 $\%$ . The coronary blood flow estimated by VDFE has better reliability than the other four existing methods. Conclusion: Our proposed VDFE is an effective approach to non-invasively compute IMR $_\text{CT}$ with excellent diagnostic performance. Significance: The VDFE has the potential to serve as a safe, effective, and cost-effective clinical tool for guiding CMD clinical treatment and assessing prognosis.