Atsushi Nishikata

Atsushi Nishikata

Auto-generated profile, based on publicly available information

Atsushi Nishikata

School of Materials and Chemical Technology, Tokyo Institute of Technology

Research Focus & Metrics

Academic Career Length

46Years (1981-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2007 in Chemical Reviews
Verified
Journal Article
Closed access
RBRod Borup
Rod Borup
JMJeremy Meyers
Jeremy Meyers
BPBryan Pivovar
Bryan Pivovar
YKYu Seung Kim
Yu Seung Kim
RMRangachary Mukundan
Rangachary Mukundan
NINorio Iwashita∞
Norio Iwashita∞

1 March 2007 in Corrosion Science
Verified
Journal Article
Closed access
YTYusuke Tsutsumi
Yusuke Tsutsumi
ANAtsushi Nishikata
Atsushi Nishikata
TTTooru Tsuru
Tooru Tsuru

1 June 1995 in Corrosion Science
Verified
Journal Article
Closed access
ANA. Nishikata
A. Nishikata
YIY. Ichihara
Y. Ichihara
TTT. Tsuru
T. Tsuru


1 April 1997 in Journal of the Electrochemical Society
Verified
Journal Article
Closed access
PDF file
ANA. Nishikata
A. Nishikata
YIY. Ichihara
Y. Ichihara
YHY. Hayashi
Y. Hayashi
TTT. Tsuru
T. Tsuru
Cathodic polarization curves for the reduction of oxygen and protons on platinum and iron electrodes under thin electrolyte layers (X f: 1 mm to 10 μm) were measured to elucidate the effects of the thickness and the pH of the electrolyte layer on the initial atmospheric corrosion stage of iron. A limiting current was exhibited on the cathodic polarization curves under neutral electrolyte layers containing 0.1 to 2 M NaCl, which was inversely proportional to the thickness of the electrolyte layer down to approximately 20 μm. This result indicates that oxygen diffusion through the electrolyte layer is the rate‐determining step (rds) for the oxygen reduction process. Meanwhile the limiting current under still thinner layers (X f: 10 to 20 μm) was independent of the thickness, where an oxygen dissolution step at the air/electrolyte interface is the rds because of the considerably higher diffusion rate under such very thin electrolyte layers. AC impedance corrosion monitoring of iron for the period of 4 h was performed under electrolyte layers of different thickness (X f: 1 mm to 10 μm) and pH (pH 3.0, 4.0, and 5.7). The results indicated that the corrosion rate showed a maximum at an electrolyte thickness of 20 to 30 μm in all cases, and the effect of pH on the atmospheric corrosion rate was negligible, except for cases wherein a relatively thick electrolyte layer (>1 mm) was present for a short exposure period (<1 h). This can be attributed to a neutralization of the electrolyte due to corrosion reaction because of the extremely limited amount of electrolyte present.

1 October 2005 in Corrosion Science
Verified
Journal Article
Closed access
TTTooru Tsuru
Tooru Tsuru
YHYanliang Huang
Yanliang Huang
RARostom Ali
Rostom Ali
ANAtsushi Nishikata
Atsushi Nishikata