Newborn screening is the largest genetic testing effort in the United States and is considered one of the ten great public health achievements during the first 10 years of the 21st century. For over 35 years, the Newborn Screening Quality Assurance Program (NSQAP) at the US Centers for Disease Control and Prevention has helped NBS laboratories ensure that their testing does not delay diagnosis, minimizes false-positive reports, and sustains high-quality testing performance. It is a multi-component program that provides comprehensive quality assurance services for dried blood spot testing. The NSQAP, the Biochemical Mass Spectrometry Laboratory (BMSL), the Molecular Quality Improvement Program (MQIP) and the Newborn Screening Translation Research Initiative (NSTRI), aid screening laboratories achieve technical proficiency and maintain confidence in their performance while processing large volumes of specimens daily. The accuracy of screening tests could be the difference between life and death for many babies; in other instances, identifying newborns with a disorder means that they can be treated and thus avoid life-long disability or severe cognitive impairment. Thousands of newborns and their families have benefited from reliable and accurate testing that has been accomplished by a network of screening laboratories and the NSQAP, BMSL, MQIP and NSTRI.
Newborn screening (NBS) laboratories cannot accurately compare mass spectrometry-derived results and cutoff values due to differences in testing methodologies. The objective of this study was to assess harmonization of laboratory proficiency test (PT) results using quality control (QC) data. Newborn Screening Quality Assurance Program (NSQAP) QC and PT data reported from 302 laboratories in 2019 were used to compare results among laboratories. QC materials were provided as dried blood spot cards which included a base pool and the base pool enriched with specific concentrations of metabolites in a linear range. QC data reported by laboratories were regressed on QC data reported by the Centers for Disease Control and Prevention (CDC), and laboratory’s regression parameters were used to harmonize their PT result. In general, harmonization tended to reduce overall variation in PT data across laboratories. The metabolites glutarylcarnitine (C5DC), tyrosine, and phenylalanine were displayed to highlight inter- and intra-method variability in NBS results. Several limitations were identified using retrospective data for harmonization, and future studies will address these limitations to further assess feasibility of using NSQAP QC data to harmonize PT data. Harmonizing NBS data using common QC materials appears promising to aid result comparison between laboratories.
In newborn screening, false-negative results can be disastrous, leading to disability and death, while false-positive results contribute to parental anxiety and unnecessary follow-ups. Cutoffs are set conservatively to prevent missed cases for Pompe and MPS I, resulting in increased falsepositive results and lower positive predictive values. Harmonization has been proposed as a way to minimize false-negative and false-positive results and correct for method differences, so we harmonized enzyme activities for Pompe and MPS I across laboratories and testing methods (Tandem Mass Spectrometry (MS/MS) or Digital Microfluidics (DMF)). Participating states analyzed proofof- concept calibrators, blanks, and contrived specimens and reported enzyme activities, cutoffs, and other testing parameters to Tennessee. Regression and multiples of the median were used to harmonize the data. We observed varied cutoffs and results. Six of seven MS/MS labs reported enzyme activities for one specimen for MPS I marginally above their respective cutoffs with results classified as negative, whereas all DMF labs reported this specimen’s enzyme activity below their respective cutoffs with results classified as positive. Reasonable agreement in enzyme activities and cutoffs was achieved with harmonization; however, harmonization does not change how a value would be reported as this is dependent on the placement of cutoffs.
Spinal muscular atrophy (SMA) was added to the HHS Secretary’s Recommended Uniform Screening Panel for newborn screening (NBS) in 2018, enabling early diagnosis and treatment of impacted infants to prevent irreversible motor neuron damage. In anticipation of supporting SMA newborn screening, scientists at the U.S. Centers for Disease Control and Prevention (CDC) have worked towards building resources for public health laboratories in four phases since 2013. In Phase 1, CDC established a real-time PCR assay, which uses a locked nucleic acid probe to attain the needed specificity, to detect SMN1 exon 7. In Phase 2, we developed quality assurance dried blood spot materials made with transduced lymphoblast cell lines established from de-identified SMA patients, carriers, and unaffected donors. In 2021, CDC implemented Phase 3, a proficiency testing program, that now supports 115 NBS labs around the world. We are currently completing Phase 4, which includes the implementation of an external SMA quality control material program. Also, during this time, CDC has provided individual technical assistance to NBS programs and bench training to NBS scientists during our annual molecular workshop. These CDC-led activities have contributed to the rapid and full implementation of SMA screening in all 50 U.S. states as of February 2024.
Lysosomal diseases (LDs, or Lysosomal Storage Disorders) have become increasingly visible in the newborn screening community, with the addition of mucopolysaccharidosis type II (MPS-II) into the Recommended Uniform Screening Panel in August 2022 and Infantile Krabbe disease in June 2024. As more LDs are expected to be considered for screening adoption, the ability to multiplex conditions and expand proficiency testing (PT) using quality control materials is essential. This study examines the use of recombinant enzymes to produce first-tier PT materials for mucopolysaccharidosis type I, MPS-II, Gaucher, Fabry, Krabbe, Pompe, and Niemann–Pick A/B (acid sphingomyelinase deficiency)—adding four disorders to the CDC’s Newborn Screening Quality Assurance Program (NSQAP) LD PT panel. Through an iterative process that included two prototype phases, two pilot phases, and external testing by up to 31 external laboratories, a new manufacturing process was developed for producing high-performing dried blood spot-based LD PT specimens. Materials were evaluated using several methods commonly employed by newborn screening laboratories, including tandem mass spectrometry with flow injection and liquid chromatography, digital microfluidics, and fluorometric assays. This novel process for producing LD PT materials offers several advantages over previous manufacturing methods that relied on immortalized cell lines from affected patients. Improved scalability, for example, has enabled NSQAP to expand LD PT enrollment internationally. Furthermore, the new process makes it easier to support future expansions of the LD screening panel. The updated specimens and expanded program were launched in January 2025.
Newborn bloodspot screening for one or more lysosomal storage disorders (NBS-LSD) is currently performed by many public health NBS laboratories globally. The screening tests measure activities of selected lysosomal enzymes on dried blood spot (DBS) specimens collected from newborns by the heel stick method Because these assays measure enzyme activity, the quantitative results are dependent on the particular analytical method. DBS quality control (DBS QC) materials with assay-specific certified values that span the relevant range from typical to LSD-affected newborns are an important component of quality assurance in NBS laboratories. The Newborn Screening Quality Assurance Program (NSQAP) at the U.S. Centers for Disease Control and Prevention (CDC) provides public health NBS laboratories with DBS QC sets for NBS-LSD comprising four admixtures of pooled umbilical cord blood and a base pool made from leukodepleted peripheral blood and heat-inactivated serum. To evaluate the suitability of these materials for use with digital microfluidics fluorometry (DMF) assays which can currently measure the activity of four enzymes (acid α-galactosidase (GLA); acid β-glucocerebrosidase (GBA); acid α-glucosidase (GAA); and iduronidase (IDUA)), CDC collaborated with the Newborn Screening Unit at the Missouri State Public Health Laboratory (MSPHL). Using MSPHL criteria, we found that the certified results from each of two DBS QC lots collectively spanned the range from typical (screen negative) to enzyme deficient (screen positive) newborn DBS levels for each of the four lysosomal enzymes measured. The range included borderline results that would require repeat screening of the newborn under the MSPHL protocol. We conclude that these DBS QC preparations are suitable for use as external quality control materials for DMF assays used to detect LSDs in newborns.