Qiaoyu Wu

Qiaoyu Wu

Auto-generated profile, based on publicly available information

Qiaoyu Wu

Tongji University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2021 in Applied Optics
Verified
Journal Article
Closed access
PDF file
QWQiaoyu Wu
Qiaoyu Wu
QHQiushi Huang
Qiushi Huang
JYJun Yu
Jun Yu
XXXudong Xu
Xudong Xu
RQRunze Qi
Runze Qi
ZWZhanshan Wang
Zhanshan Wang
To accurately measure the surface figure of curved mirrors with large radius of curvature (RoC) using stitching interferometry methods, three types of measurement errors are systematically studied, including retrace error, defocusing error within a single subaperture, and stitching angle error among different subapertures. It was found that part of the retrace error caused by the mismatch between the reference wavefront and reflected wavefront has little effect, while the overall retrace error, including the influence of the imperfect optical elements, will cause an error of 1–2 nm RMS within a single subaperture. Defocusing error will enlarge the error due to amplification of optical path error caused by the deviation of the position of the CCD. Because the error is mainly in the edge area, a slope threshold, which controls the maximum surface slope of each subaperture, can be optimized to reduce the effect of the defocus on stitching measurement error. Constant angle error among neighboring subapertures has the biggest accumulation effect on the final stitched figure. For the spherical mirror with RoC of 100 m of 80 m m × 40 m m , the error of the one-dimensional residual profile is 4.67 nm PV, assuming a constant angle error of 2 × 10 − 7 r a d . For the elliptical mirror with RoC of 60–140 m, it is more than 15 nm peak-to-valley (PV). It is because the profile difference caused by constant angle error is closer to a circle, which can be mostly removed after subtraction of a best-fit sphere. Based on the above error analysis, the developed algorithm-based stitching method was used to measure an elliptical cylindrical mirror of 74 m m × 40 m m with RoC of 60–140 m, and the result was compared with a slope measurement instrument from the Beijing Synchrotron Radiation Facility. After removing the best fitting ellipse profile, the one-dimensional difference between the two results is only 0.77 nm RMS, which demonstrated good measurement accuracy.

1 May 2023 in Optics Express
Verified
Journal Article
Closed access
QWQiaoyu Wu
Qiaoyu Wu
QHQiushi Huang
Qiushi Huang
JYJun Yu
Jun Yu
YZYifan Zhu
Yifan Zhu
WGWeicheng Gu
Weicheng Gu
ZWZhanshan Wang
Zhanshan Wang
This work presents a mixed stitching interferometry method with correction from one-dimensional profile measurements. This method can correct the error of stitching angles among different subapertures using the relatively accurate one-dimensional profiles of the mirror, e.g., provided by the contact profilometer. The measurement accuracy is simulated and analyzed. The repeatability error is decreased by averaging multiple measurements of the one-dimensional profile and using multiple profiles at different measurement positions. Finally, the measurement result of an elliptical mirror is presented and compared with the global algorithm-based stitching, and the error of the original profiles is reduced to one-third. This result shows that this method can effectively suppress the accumulation of stitching angle errors in classic global algorithm-based stitching. The accuracy of this method can be further improved by using high-precision one-dimensional profile measurements such as the nanometer optical component measuring machine (NOM).

3 December 2024 in Optics Express
Verified
Journal Article
Closed access
QWQiaoyu Wu
Qiaoyu Wu
QHQiushi Huang
Qiushi Huang
WZWenwen Zhang
Wenwen Zhang
ZSZhao Shi
Zhao Shi
MLMing Li
Ming Li
ZWZhanshan Wang
Zhanshan Wang
For high-precision metrology of X-ray mirrors, the subaperture moving strategy significantly impacts the accuracy of stitching interferometry. In this work, we investigated the systematic errors associated with various subaperture moving strategies of rotational stitching (RS), rotational displacement stitching (RDS), and displacement stitching (DS) in measuring X-ray mirrors. The effects of stitching strategies on a flat mirror and a spherical mirror with a radius of curvature (RoC) of 180 m and 60 m were compared. For the mirror with RoC of 60 m, the DS strategy showed the smallest height error of 3.3 nm (RMS) between algorithm-based stitching and the Nanometer Optical component Measuring machine (NOM), while RS showed a large error of 37.4 nm (RMS). The different regions of the interferometer aperture have different amplitudes of retrace errors, defocusing errors, and lateral distortion, which can lead to accumulations of systematic errors using the RS strategy. By reducing the pixel size from 0.268 mm/pixel to 0.089 mm/pixel, the measurement accuracy using the same RDS strategy improved from 7.4 nm (RMS) to 4.4 nm (RMS). Based on the optimal stitching strategy, the measurement accuracy of residual figure error of the X-ray mirror with a radius of curvature of 30 m reaches 0.2 nm (RMS).