1 November 2020 in Solar Energy
FAFernando Antonanzas-Torres
Fernando Antonanzas-Torres
+27
1 November 2020 in Solar Energy
1 May 2015 in Solar Energy
Synthetic minutely irradiance time series are utilised in non-spatial solar energy system research simulations. It is necessary that they accurately capture irradiance fluctuations and variability inherent in the solar resource. This article describes a methodology to generate a synthetic minutely irradiance time series from widely available hourly weather observation data. The weather observation data are used to produce a set of Markov chains taking into account seasonal, diurnal, and pressure influences on transition probabilities of cloud cover. Cloud dynamics are based on a power-law probability distribution, from which cloud length and duration are derived. Atmospheric transmission losses are simulated with minutely variability, using atmospheric profiles from meteorological reanalysis data and cloud attenuation derived real-world observations. Both direct and diffuse irradiance are calculated, from which total irradiance is determined on an arbitrary plane. The method is applied to the city of Leeds, UK, and validated using independent hourly radiation measurements from the same site. Variability and ramp rate are validated using 1-min resolution irradiance data from the town of Cambourne, Cornwall, UK. The hourly irradiance frequency distribution correlates with R2=0.996 whilst the mean hourly irradiance correlates with R2=0.971, the daily variability indices cumulative probability distribution function (CDF), 1-min irradiance ramp rate CDF and 1-min irradiance frequency CDF are also shown to correlate with R2=0.9903,1.000, and 0.9994 respectively. Kolmogorov–Smirnov tests on 1-min data for each day show that the ramp rate frequency of occurrence is captured with a high significance level of 99.99%, whilst the irradiance frequency distribution and minutely variability indices are captured at significances of 99% and 97.5% respectively. The use of multiple Markov chains and detailed consideration of the atmospheric losses are shown to be essential elements for the generation of realistic minutely irradiance time series over a typical meteorological year. A freely downloadable example of the model is made available and may be configured to the particular requirements of users or incorporated into other models
1 July 2018 in Solar Energy
1 March 2017 in Solar Energy
The statistics of clear-sky index can be used to determine solar irradiance when the theoretical clear sky irradiance and the cloud cover are known. In this paper, observations of hourly clear-sky index for the years of 2010–2013 at 63 locations in the UK are analysed for over 1 million data hours. The aggregated distribution of clear-sky index is bimodal, with strong contributions from mostly-cloudy and mostly-clear hours, as well as a lower number of intermediate hours. The clear-sky index exhibits a distribution of values for each cloud cover bin, measured in eighths of the sky covered (oktas), and also depends on solar elevation angle. Cloud cover is measured either by a human observer or automatically with a cloud ceilometer. Irradiation (time-integrated irradiance) values corresponding to human observations of “cloudless” skies (0 oktas) tend to agree better with theoretical clear-sky values, which are calculated with a radiative transfer model, than irradiation values corresponding to automated observations of 0 oktas. It is apparent that the cloud ceilometers incorrectly categorise more non-cloudless hours as cloudless than human observers do. This leads to notable differences in the distributions of clear-sky index for each okta class, and between human and automated observations. Two probability density functions—the Burr (type III) for mostly-clear situations, and generalised gamma for mostly-cloudy situations—are suggested as analytical fits for each cloud coverage, observation type, and solar elevation angle bin. For human observations of overcast skies (8 oktas) where solar elevation angle exceeds 10°, there is no significant difference between the observed clear-sky indices and the generalised gamma distribution fits.
1 May 2017 in Solar Energy
Residential photovoltaic (PV) technology is expected to have mass global deployment. With widespread PV in the electricity distribution grids, the variable nature of the solar resource must be understood to facilitate reliable operation. This research demonstrates that synthetic, 1-min resolution irradiance time series that vary on a spatial dimension can be generated based on the following inputs: mean hourly meteorological observations of okta, wind speed, cloud height and atmospheric pressure. The synthetic time series temporally validate against observed 1-min irradiance data for four locations—Cambourne, UK; Lerwick, UK; San Diego, CA USA; and Oahu, HI USA—when analysing 4 metrics of variability indices, ramp-rate size, irradiance magnitude frequency and clear-sky index frequency. Each metric is calculated for the modelled and observed data at each location and CDF profile correlation compared as well as applying the Kolmogorov-Smirnov (K–S) test with 99% confidence limits. CDF correlation coefficients of each metric are all above R⩾0.908, and a minimum of 90.96% of daily irradiance time series passed the K–S test. A spatial validation was performed comparing the model outputs to real observation data. The spatial correlation coefficient regression with site separation was successfully recreated with MAPE = 0.865%, RMSE = 0.01 and R=0.955. The spatial instantaneous correlation was shown to behave anisotropically when using fixed cloud direction, with different correlation in along and cross wind directions. Cloud cover states of 40–60% showed the most spatial decorrelation while 0% and 100% had the least. The model outputs are applied to a distribution grid impact model using the IEEE-8500 node test feeder. PV scenarios of 25%,50%, and 75% uptake were modelled across a 1.5×1.5 km grid. The magnitude and frequency of severe tap changing events are found to be significantly higher when using a single irradiance time series for all PV systems versus individually assigning spatially decorrelating time series.