1 January 2010 in Marine Structures
1 January 2021 in IEEE Transactions on Instrumentation and Measurement
10 September 2018 in Jurnal Nasional Teknik Elektro dan Teknologi Informasi
Wireless Sensor Network (WSN) is small embedded devices deployed in large scale network and has capability to sense, compute, and communicate with others. It combines modern sensor, microelectronic, computer, communication, and distributed processing technology. It takes into account in several aspects of live especially in structural health monitoring system of bridge. Due to environmental circumstance, a bridge should be monitored to make sure that it can perform its service safely. Therefore, it is necessary to develop WSN application to monitor bridge condition and send warning message to control room if the bridge is under abnormal condition. This paper proposes the development of automatic WSN system for measuring the level of bridge structural health based on its dynamic responses. The main contribution of this work is developing WSN system for vibration-based bridge condition assessment in which identifies the bridge’s fundamental frequency and mode shape. Experimental result shows that the fundamental frequency measured by our proposed system is close to the value analyzed using finite element analysis (FEA) and according to Modal Assurance Criteriation (MAC), our proposed measurement system has correlation with FEA.
22 August 2018 in MATEC Web of Conferences
Currently, design of reinforced concrete buildings is still dominated with normal strength reinforcing bars, not exceeding 420 MPa yield strength. Meanwhile, the use of higher strength reinforcing bars tend to increase due to some benefits in the construction, such as reducing the total weight of reinforcing bars and alleviating reinforcing bars congestions. In this study, reinforcing bars with yield strength of 520 MPa are utilized in the reinforced concrete beam-column joint. The objective is to study the seismic performance of reinforced concrete beam-column joints. A total of 3 interior beam-column joints, half-scaled specimens with different yield strengths and bar diameters was tested. One of the test specimens which was 16 mm diameter and had normal strength reinforcing bar. The other two specimens use high strength reinforcing bars, and have 16 mm and 19 mm diameter bars. Loading protocol of all the specimens is conformed with ACI 374.2. Dissipation energy and deformability of the joints is then compared. Normalized energy dissipation of the specimens with high strength reinforcing bars was slightly lower than that of the specimens with normal reinforcing bars. However, specimens with high strength reinforcing bars tend to have smaller deformability than that of the specimens with normal reinforcing bars.
25 January 2019 in MATEC Web of Conferences
KKKurniawan S. Kamaruddin
The use of high strength reinforcing bars has becoming an interesting and cost-efficient option in construction industry recently. However, their use is limited due to their low deformability which might induce a brittle collapse in the structures. Also, longer development length is needed to transfer stress from reinforcing bars to the surrounding concrete. This paper focuses on investigating the influence of fibrous concrete and high-strength reinforcing bars on the behavior of structural elements. Five half-scaled specimens of interior joints using plain or fibrous concrete, reinforced with conventional 420 MPa or high strength reinforcing bar of 520 Mpa were experimentally tested. The two specimens of plain concrete, reinforced longitudinally with 16 mm and 19 mm reinforcing bars are defined as control specimens. The other test specimens were casted with Polypropylene fiber reinforced concrete (PFRC) with 16 mm and 19 mm longitudinal reinforcing bar. Loading protocol of all test specimens is defined according to ACI 374.2. The structure behavior, such as dissipated energy, bond between reinforcing bars and surrounding concrete, and stiffness degradation of the four specimens were evaluated and compared. The results obtained shows that the use of fiber increase the dissipated energy up to 27.5 % compared to specimens with plain concrete. Moreover, the peak strength of PFRC specimens was slightly increased (3% - 7%) compared to that of specimens with plain concrete. Moreover, there is an increase in peak-to-peak stiffness at elastic range loading with the addition of fiber, while no significant difference after the yields of longitudinal reinforcing bars.