11 April 2019 in Scientific Reports
To develop a wearable multi-lead electrocardiogram (ECG) measuring system, we fabricated the electrodes and wires by using electrostatic flocking technology on a textile. By using this technology, it was possible to fabricate many electrodes and wires, simultaneously. Also the flocked electrodes and wires had stretchability and washing resistance properties. To use dry electrodes, it is important to reduce the influence of motion artifacts (MAs). The results of the experiment with the skin phantom revealed that the contact pressure between the skin and the electrode is an important factor in MA reduction. Then, we conducted experiments with a human body to determine the relationship between the contact pressure and the MAs. Under the pressures of 200 Pa and 500 Pa, MAs were observed. Meanwhile, under the pressures of 1000 Pa, 2000Pa and 4000 Pa, the ECG signals under rest and deep breathing conditions were able to be measured without MAs. Considering the comfortability, the contact pressure from 1000 Pa to 2000 is preferable. Finally, we fabricated the wearable ECG measuring system and succeeded in measuring 18-lead ECG signals. The measured ECG waveform is in good agreement with the ECG waveform measured by a commercial system.
11 November 2022 in Scientific Reports
This paper describes the fabrication and fundamental evaluation of the cubic flocked electrode (CFE), which is a dry electrode that is fabricated using electrostatic flocking technology. The development of a wearable multi-lead electrocardiogram (ECG) measurement device using the CFE is also reported. To enable the measurement of ECG signals with sufficient quality for medical applications, the occurrence of motion artifacts (MAs) is the most important problem to be overcome. Therefore, it is necessary to stabilize the contact between the patient’s skin and the dry electrode. Because the CFE developed in this work offers both contact stability and flexibility, it is expected to enable ECG measurements with low MA levels. In this study, it is demonstrated that the number of MAs caused by respiration can be reduced when the CFE contact is made at a contact pressure of approximately 500 Pa using MA evaluation equipment that was developed in-house. Additionally, a wearable multi-lead ECG is designed and fabricated based on this contact pressure (500 Pa). The results of the demonstration experiment show that the ECG measurements are successful to the same extent as a conventional medical device.
13 March 2017 in Japanese Journal of Applied Physics
We proposed and developed soft-rubber-packaged Pb(Zr,Ti)O 3 (PZT) microelectromechanical systems (MEMS) force sensors as human–machine interface sensors of human touch and input. To achieve small and highly sensitive sensors with low-power-consumption, a small PZT MEMS cantilever was used as the sensing element, and it was covered with soft rubber, poly(dimethylsiloxane) (PDMS), to prevent the cracking of the brittle PZT film when touching the sensor. The PDMS packaging does not affect the ferroelectric characteristics of the sensing PZT film, because the hysteresis and impedance changes of the PZT are less than 5%. The sensor dimensions are 5 × 5 × 1.1 mm 3 . The sensor generated charges without requiring voltage supply. The sensor generated an electric charge of 7.8 pC under an applied force of 1 N. The sensitivity was adjusted by changing the hardness of the soft rubber package: hard rubber provides high sensitivity, but the sensor is easily cracks. Hence, a sensor with a durometer hardness A of 35.6 was found to be optimal as a human–machine interface sensors of human touch of approximately 5–7 N because it has a linear sensitivity at force smaller than 5 N and the bending is small at forces larger than 5 N, which leads to a highly durable sensor. The sensor with a durometer hardness A of 35.6 did not break or crack until the applied force reached 40 N. By packaging brittle PZT MEMS cantilevers with soft rubber, small-force sensors can be constructed, leading to small, low-energy-consumption human–machine interface sensors.
15 September 2016 in Japanese Journal of Applied Physics
We fabricated a MEMS actuator device that is used as an actuator component of an optical scanning device without deflection of the device using finite element method (FEM) software. When Pt/Ti/PZT/Pt/Ti/SiO2 multilayers were deposited on a silicon-on-insulator (SOI) wafer in order to fabricate the MEMS actuator device, the wafer was deflected because of inner stress generated by thin-film deposition, and as a result, the MEMS actuator device using the deflected wafer was also deflected. We aimed to define the relationship between the deflection of the SOI wafer and the deflection of the MEMS actuator device by simulation. Moreover, by using this relationship, we determined the optimal deflection of the SOI wafer after the deposition of thin films, enabling the fabrication of a MEMS actuator device without deflection, by simulation. From the simulation result, when the changes in the deflection of SOI wafers were 14.1 and 7.4 µm, the displacements of the MEMS actuator device were 1.1 and 5.7 µm, respectively. The simulation results were in good agreement with the experimental results. From the simulation results, the optimal wafer deflection for preventing the deflection of the MEMS actuator device was 15.6 µm. This value was close to the experimental value, 14.1 µm. This method enables easy simulation of any MEMS device that is complicated in design and which uses multilayer thin films.
18 August 2022 in Japanese Journal of Applied Physics
We describe the fabrication and evaluation of a nail-deformation haptics actuator having a flexible haptics film. The novelty of the developed actuator is the generation of a vibration that directly deforms the nail and finger pad. The flexible piezo-MEMS film is fabricated adopting ultra-thin lead-zirconate-titanate microelectromechanical system (MEMS) and lamination technology. The flexible piezo-MEMS film has flexibility (thickness: 65 μ m) and low weight (mass: 55 mg). The device can thus be attached on a nail without discomfort. A nail-deformation haptics actuator was fabricated by attaching this flexible piezo-MEMS film on an artificial nail. When applying a DC voltage of 40 V to the film, there was a strain of −36.5 × 10 −6 in the cylindrical direction of the nail and −12.1 × 10 −6 in the circumferential direction. Furthermore, applying an AC voltage (40 V pp , 20 V offset ) at a frequency of 200–300 Hz, the finger pad deformed sufficiently to perceive vibration.
2 March 2020 in Flexible and Printed Electronics
A flexible substrate with a novel floating island structure design was developed for mounting ultra-thin silicon chips. The structure reduced the strain propagated from the stretching base to the ultra-thin silicon chips. While conventional structures reduce strain by 64.2%, the floating island structure reduced strain by 90.2%. Furthermore, tests for operational stability and durability were conducted using an ultra-thin operational amplifier (OPAMP) mounted on the flexible substrate with a floating island structure, where the OPAMP was thinned to 30 µm by chemical mechanical polishing. The ultra-thin OPAMP operated with no strain effects even when repeatedly stretched to 30% elongation. Also, the ultra-thin silicon chip mounted on the floating island structure demonstrated durability against >25000 stretching cycles. This research is applicable for functional wearable devices using ultra-thin silicon chips and featuring high flexibility and stretchability.