Nurul Hana Mokhtar Kamal

Nurul Hana Mokhtar Kamal

Auto-generated profile, based on publicly available information

Nurul Hana Mokhtar Kamal

School of Civil Engineering, Engineering Campus, Universiti Sains Malaysia, Nibong Tebal, Pulau Pinang 14300, Malaysia

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2015 in Water Research
Verified
Journal Article
Open access
TBTom Bond
Tom Bond
MTMichael R. Templeton
Michael R. Templeton
NKNurul Hana Mokhtar Kamal
Nurul Hana Mokhtar Kamal
NGNigel Graham
Nigel Graham
Rakesh KandaRakesh Kanda
Rakesh Kanda
Despite the recent focus on nitrogenous disinfection byproducts in drinking water, there is limited occurrence data available for many species. This paper analyses the occurrence of seven haloacetonitriles, three haloacetamides, eight halonitromethanes and cyanogen chloride in 20 English drinking water supply systems. It is the first survey of its type to compare bromine substitution factors (BSFs) between the haloacetamides and haloacetonitriles. Concentrations of the dihalogenated haloacetonitriles and haloacetamides were well correlated. Although median concentrations of these two groups were lower in chloraminated than chlorinated surface waters, median BSFs for both in chloraminated samples were approximately double those in chlorinated samples, which is significant because of the higher reported toxicity of the brominated species. Furthermore, median BSFs were moderately higher for the dihalogenated haloacetamides than for the haloacetonitriles. This indicates that, while the dihalogenated haloacetamides were primarily generated from hydrolysis of the corresponding haloacetonitriles, secondary formation pathways also contributed. Median halonitromethane concentrations were remarkably unchanging for the different types of disinfectants and source waters: 0.1 μg · mgTOC(-1) in all cases. Cyanogen chloride only occurred in a limited number of samples, yet when present its concentrations were higher than the other N-DBPs. Concentrations of cyanogen chloride and the sum of the halonitromethanes were not correlated with any other DBPs.

1 August 2014 in Journal of Hazardous Materials
Verified
Journal Article
Open access
TBTom Bond
Tom Bond
NKNurul Hana Mokhtar Kamal
Nurul Hana Mokhtar Kamal
TBThomas Bonnisseau
Thomas Bonnisseau
MTMichael R. Templeton
Michael R. Templeton
This study investigated the relative effect of chlorination and chloramination on DBP formation from seven model amine precursor compounds, representative of those commonly found in natural waters, at pH 6, 7 and 8. The quantified DBPs included chloroform, dichloroacetonitrile (DCAN), trichloroacetonitrile (TCAN) and chloropicrin (trichloronitromethane). The aggregate formation (i.e. the mass sum of the formation from the individual precursors) of chloroform, DCAN and TCAN from all precursors was reduced by respectively 75-87%, 66-90% and 89-93% when considering pre-formed monochloramine compared to chlorine. The formation of both haloacetonitriles decreased with increasing pH following chlorination, but formation after chloramination was relatively insensitive to pH change. The highest formation of chloropicrin was from chloramination at pH 7. These results indicate that, while chloramination is effective at reducing the concentrations of trihalomethanes and haloacetonitriles in drinking water compared with chlorination, the opposite is true for the halonitromethanes.

13 December 2023 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
SISiti Aisyah Ishak
Siti Aisyah Ishak
MMMohamad Fared Murshed
Mohamad Fared Murshed
MZMohd Remy Rozainy Mohd Arif Zainol
Mohd Remy Rozainy Mohd Arif Zainol
NKNurul Hana Mokhtar Kamal
Nurul Hana Mokhtar Kamal
This study involved synthesising new hybrid polymers called ZOPAT, made up of zinc oxide, acrylamide, and tannin, using a blended technique. The effectiveness of ZOPAT in treating textile wastewater was then tested by measuring floc growth rate, flocculation index, strength factor, and recovery factor under optimised conditions. The study also identified the zeta potential, morphology, elemental composition, and functional groups of the polymers. Response surface methodology determines the optimal pH and ZOPAT dose, resulting in 93% colour, 80% chemical oxygen demand (COD), 100% turbidity, and suspended solids (SS) removal at pH 9.22 and 737 mg/L ZOPAT. The study found that ZOPAT was more effective than commercial Polyaluminium chloride in reducing colour and COD, producing larger and stronger flocs, and requiring a shorter coagulation time of 17.5 min. ZOPAT was also easy to homogenise and operate due to its one-unit dosing system. The study attributes the success of ZOPAT to the presence of Zn, N, and K, which create electrostatic attraction with opposite charged particles, and the formation of dye–particle–dye with amide, hydroxyl, and carboxyl groups in ZOPAT, which remove colour, turbidity, COD, and SS. Overall, the study concludes that ZOPAT has significant potential for textile wastewater treatment.

1 January 2017 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
RSRossitah Selamat
Rossitah Selamat
IAIsmail Abustan
Ismail Abustan
MAMohd Rizal Arshad
Mohd Rizal Arshad
NKNurul Hana Mokhtar Kamal
Nurul Hana Mokhtar Kamal
A 50 Hz low-frequency electromagnetic field (LF-EMF) could give removal effect on the growth of Escherichia coli (E. coli) in the riverbank filtration (RBF) was studied. The LF-EMF strengths were varied from 2 to 10 mT using coil column induce magnetic fields. For this study, two different columns with a diameter of 50 mm and 80 mm were applied; 1.5mm copper wires with the number of turns between 300 to 600 turns. Water samples were flowed into the column at flowrate of 50mL/min with temperature in range of 28–30°C. This study, it was found that the LF-EMF has significant removal effects on E. coli growth, where the removal of 100% of E. coli at 6 mT and 8 mT after 6 hrs exposed. Moreover, for shorter exposure period of 3 hrs exposed, 82% of E. coli removal were detected in 80 mm column for 8 mT and 10 mT magnetic field. These findings indicate that the application of LF-EMF is able to decrease the E. coli, can be and efficient in E. coli growth from river water intake. Thus, the results from this study proved that the utilization of LF-EMF is able to decrease the concentrations of E. coli, and contributes in slowing down their growth. Also, it can be indicated that the LF-EMF kill a part of E. coli exposed in the river water with the large magnetic field and long-time exposure.

29 November 2019
Verified
Book Chapter
Closed access
PDF file
SYSyafinah Yusoff
Syafinah Yusoff
NZNastaein Qamaruz Zaman
Nastaein Qamaruz Zaman
AYAhmad Shukri Yahya
Ahmad Shukri Yahya
NKNurul Hana Mokhtar Kamal
Nurul Hana Mokhtar Kamal

6 August 2026 in Ecohydrology & Hydrobiology
Verified
Journal Article
Closed access
SSSyafiq Shaharuddin
Syafiq Shaharuddin
NKNurul Hana Mokhtar Kamal
Nurul Hana Mokhtar Kamal
NSNoor Aida Saad
Noor Aida Saad
SLSukratta Cham Long
Sukratta Cham Long
MMMohamad Aiman Iqbal Abdul Majid
Mohamad Aiman Iqbal Abdul Majid
MZMohd Remy Rozainy Mohd Arif Zainol
Mohd Remy Rozainy Mohd Arif Zainol