A 263 GHz continuous-wave (CW) gyrotron was developed at the IAP RAS for future applications as a microwave power source in Dynamic Nuclear Polarization / Nuclear magnetic resonance (DNP/NMR) spectrometers. A new experimental facility with a computerized control was built to test this and subsequent gyrotrons. We obtained the maximum CW power up to 1 kW in the 15 kV/0.4 A operation regime. The power about 10 W, which is sufficient for many spectroscopic applications, was realized in the low current 14 kV/0.02 A regime. The possibility of frequency tuning by variation of the coolant temperature about 4 MHz/1 °C was demonstrated. The spectral width of the gyrotron radiation was about 10−6.
Many state-of-the-art fundamental and industrial projects need the use of terahertz radiation with high power and small linewidth. Gyrotrons as radiation sources provide the desired level of power in the sub-THz and THz frequency range, but have substantial free-running frequency fluctuations of the order of 10−4. Here, we demonstrate that the precise frequency stability of a high-power sub-THz gyrotron can be achieved by a phase-lock loop in the anode voltage control. The relative width of the frequency spectrum and the frequency stability obtained for a 0.263 THz/100 W gyrotron are 4 × 10−12and 10−10, respectively, and these parameters are better than those demonstrated so far with high-power sources by almost three orders of magnitude. This approach confirms its potential for ultra-high precision spectroscopy, the development of sources with large-scale radiating apertures, and other new projects.
A 250 GHz continuous-wave (CW) gyrotron has been developed at the IAP RAS jointly with GYCOM Ltd., as a prototype of the microwave source for the envisaged prospective nuclear fusion power plants (DEMO). The main applications of such a tube are electron cyclotron resonance heating and electron cyclotron resonance current drive of magnetically confined plasma as well as its diagnostics based on collective Thomson scattering in various reactors for controlled thermonuclear fusion (e.g., tokamaks and stellarators). The results of the preliminary experimental tests in a pulsed mode of operation are presented. The microwave power of up to 330 kW with an efficiency of 30% without collector depression was obtained. At an accelerating voltage of 55 kV and an electron beam current of 12.5 A (which corresponds to the design parameters for CW operation), the measured output power was about 200 kW. The TEM00 mode content evaluated at the tube output is not less than 98.6%.
A method of increasing the selectivity of highly-oversized open cavities is experimentally demonstrated in the electron cyclotron maser (gyrotron) operating at the second cyclotron harmonic in a high transverse mode (presumably, TE58;13) of a circular cylindrical cavity at a frequency near 1.2 THz in the magnetic field of 24 T. This method is purely electrodynamical and based on a simple deformation of the cavity wall. The proposed approach paves the way for increase of the gyrotron frequencies and for enhancing the selectivity of open cavities in other applications.
To cover the so-called terahertz gap in powerful sources of coherent electromagnetic waves, a second-harmonic gyrotron operating in a 10 T liquid helium-free superconducting magnet has been designed, manufactured, and tested. With an operating voltage of 15 kV and a beam current of 0.6 A, the gyrotron generated coherent continuous-wave radiation at a frequency of 0.526 Terahertz with an output power of 250 Watts and an efficiency of 2.7%.