Riku Huttunen

Riku Huttunen

Auto-generated profile, based on publicly available information

Riku Huttunen

Department of Technical Physics, University of Eastern Finland, Kuopio, Finland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
RHRiku Huttunen
Riku Huttunen
Timo LeppänenTimo Leppänen
Timo Leppänen
BDBrett Duce
Brett Duce
Erna Sif ArnardóttirErna Sif Arnardóttir
Erna Sif Arnardóttir
SNSami Nikkonen
Sami Nikkonen
HKHenri Korkalainen
Henri Korkalainen
Objective: Obstructive sleep apnea (OSA) is diagnosed using the apnea-hypopnea index (AHI), which is the average number of respiratory events per hour of sleep. Recently, machine learning algorithms for automatic AHI assessment have been developed, but many of them do not consider the individual sleep stages or events. In this study, we aimed to develop a deep learning model to simultaneously score both sleep stages and respiratory events. The hypothesis was that the scoring and subsequent AHI calculation could be performed utilizing pulse oximetry data only. Methods: Polysomnography recordings of 877 individuals with suspected OSA were used to train the deep learning models. The same architecture was trained with three different input signal combinations (model 1: photoplethysmogram (PPG) and oxygen saturation (SpO $_{2}$ ); model 2: PPG, SpO $_{2}$ , and nasal pressure; model 3: SpO $_{2}$ , nasal pressure, electroencephalogram (EEG), oronasal thermocouple, and respiratory belts). Results: Model 1 reached comparative performance with models 2 and 3 for estimating the AHI (model 1 intraclass correlation coefficient (ICC) = 0.946; model 2 ICC = 0.931; model 3 ICC = 0.945), and REM-AHI (model 1 ICC = 0.912; model 2 ICC = 0.921; model 3 ICC = 0.883). The automatic sleep staging accuracies (wake/N1/N2/N3/REM) were 69%, 70%, and 79% with models 1, 2, and 3, respectively. Conclusion: AHI can be estimated using pulse oximetry-based automatic scoring. Explicit scoring of sleep stages and respiratory events allows visual validation of the automatic analysis, and provides information on OSA phenotypes. Significance: Automatic scoring of sleep stages and respiratory events with a simple pulse oximetry setup could allow cost-effective, large-scale screening of OSA.

5 June 2021 in SLEEP
Verified
Journal Article
Open access
PDF file
RHRiku Huttunen
Riku Huttunen
Timo LeppänenTimo Leppänen
Timo Leppänen
BDBrett Duce
Brett Duce
AOArie Oksenberg
Arie Oksenberg
SMSami Myllymaa
Sami Myllymaa
HKHenri Korkalainen
Henri Korkalainen
To assess the relationship between obstructive sleep apnea (OSA) severity and sleep fragmentation, accurate differentiation between sleep and wakefulness is needed. Sleep staging is usually performed manually using electroencephalography (EEG). This is time-consuming due to complexity of EEG setup and the amount of work in manual scoring. In this study, we aimed to develop an automated deep learning-based solution to assess OSA-related sleep fragmentation based on photoplethysmography (PPG) signal. A combination of convolutional and recurrent neural networks was used for PPG-based sleep staging. The models were trained using two large clinical datasets from Israel (n = 2149) and Australia (n = 877) and tested separately on three-class (wake/NREM/REM), four-class (wake/N1 + N2/N3/REM), and five-class (wake/N1/N2/N3/REM) classification. The relationship between OSA severity categories and sleep fragmentation was assessed using survival analysis of mean continuous sleep. Overlapping PPG epochs were applied to artificially obtain denser hypnograms for better identification of fragmented sleep. Automatic PPG-based sleep staging achieved an accuracy of 83.3% on three-class, 74.1% on four-class, and 68.7% on five-class models. The hazard ratios for decreased mean continuous sleep compared to the non-OSA group obtained with Cox proportional hazards models with 5-s epoch-to-epoch intervals were 1.70, 3.30, and 8.11 for mild, moderate, and severe OSA, respectively. With EEG-based hypnograms scored manually with conventional 30-s epoch-to-epoch intervals, the corresponding hazard ratios were 1.18, 1.78, and 2.90. PPG-based automatic sleep staging can be used to differentiate between OSA severity categories based on sleep continuity. The differences between the OSA severity categories become more apparent when a shorter epoch-to-epoch interval is used.

11 February 2021 in Biomolecules
Verified
Journal Article
Open access
PDF file
KLKaisa Liimatainen
Kaisa Liimatainen
RHRiku Huttunen
Riku Huttunen
Leena LatonenLeena Latonen
Leena Latonen
PRPekka Ruusuvuori
Pekka Ruusuvuori
Identifying localization of proteins and their specific subpopulations associated with certain cellular compartments is crucial for understanding protein function and interactions with other macromolecules. Fluorescence microscopy is a powerful method to assess protein localizations, with increasing demand of automated high throughput analysis methods to supplement the technical advancements in high throughput imaging. Here, we study the applicability of deep neural network-based artificial intelligence in classification of protein localization in 13 cellular subcompartments. We use deep learning-based on convolutional neural network and fully convolutional network with similar architectures for the classification task, aiming at achieving accurate classification, but importantly, also comparison of the networks. Our results show that both types of convolutional neural networks perform well in protein localization classification tasks for major cellular organelles. Yet, in this study, the fully convolutional network outperforms the convolutional neural network in classification of images with multiple simultaneous protein localizations. We find that the fully convolutional network, using output visualizing the identified localizations, is a very useful tool for systematic protein localization assessment.

30 January 2023 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
MRMatias Rusanen
Matias Rusanen
RHRiku Huttunen
Riku Huttunen
HKHenri Korkalainen
Henri Korkalainen
Sami MyllymaaSami Myllymaa
Sami Myllymaa
JTJuha Töyräs
Juha Töyräs
SKSamu Kainulainen
Samu Kainulainen
Reliable, automated, and user-friendly solutions for the identification of sleep stages in home environment are needed in various clinical and scientific research settings. Previously we have shown that signals recorded with an easily applicable textile electrode headband (FocusBand, T 2 Green Pty Ltd) contain characteristics similar to the standard electrooculography (EOG, E1–M2). We hypothesize that the electroencephalographic (EEG) signals recorded using the textile electrode headband are similar enough with standard EOG in order to develop an automatic neural network-based sleep staging method that generalizes from diagnostic polysomnographic (PSG) data to ambulatory sleep recordings of textile electrode-based forehead EEG. Standard EOG signals together with manually annotated sleep stages from clinical PSG dataset ( n = 876) were used to train, validate, and test a fully convolutional neural network (CNN). Furthermore, ambulatory sleep recordings including a standard set of gel-based electrodes and the textile electrode headband were conducted for 10 healthy volunteers at their homes to test the generalizability of the model. In the test set ( n = 88) of the clinical dataset, the model's accuracy for 5-stage sleep stage classification was 80% (κ = 0.73) using only the single-channel EOG. The model generalized well for the headband-data, reaching 82% (κ = 0.75) overall sleep staging accuracy. In comparison, accuracy of the model was 87% (κ = 0.82) in home recordings using the standard EOG. In conclusion, the CNN model shows potential on automatic sleep staging of healthy individuals using a reusable electrode headband in a home environment.

23 October 2024 in Journal of Sleep Research
Verified
Journal Article
Open access
MRMatias Rusanen
Matias Rusanen
GJGabriel Jouan
Gabriel Jouan
RHRiku Huttunen
Riku Huttunen
SNSami Nikkonen
Sami Nikkonen
SSSigríður Sigurðardóttir
Sigríður Sigurðardóttir
HKHenri Korkalainen
Henri Korkalainen
Summary: State‐of‐the‐art automatic sleep staging methods have demonstrated comparable reliability and superior time efficiency to manual sleep staging. However, fully automatic black‐box solutions are difficult to adapt into clinical workflow due to the lack of transparency in decision‐making processes. Transparency would be crucial for interaction between automatic methods and the work of sleep experts, i.e., in human‐in‐the‐loop applications. To address these challenges, we propose an automatic sleep staging model (aSAGA) that effectively utilises both electroencephalography and electro‐oculography channels while incorporating transparency of uncertainty in the decision‐making process. We validated the model through extensive retrospective testing using a range of datasets, including open‐access, clinical, and research‐driven sources. Our channel‐wise ensemble model, trained on both electroencephalography and electro‐oculography signals, demonstrated robustness and the ability to generalise across various types of sleep recordings, including novel self‐applied home polysomnography. Additionally, we compared model uncertainty with human uncertainty in sleep staging and studied various uncertainty mapping metrics to identify ambiguous regions, or “grey areas”, that may require manual re‐evaluation. The validation of this grey area concept revealed its potential to enhance sleep staging accuracy and to highlight regions in the recordings where sleep experts may struggle to reach a consensus. In conclusion, this study provides a technical basis and understanding of automatic sleep staging uncertainty. Our approach has the potential to improve the integration of automatic sleep staging into clinical practice; however, further studies are needed to test the model prospectively in real‐world clinical settings and human‐in‐the‐loop scoring applications.

1 July 2025 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
MTMasoumeh Tashakori
Masoumeh Tashakori
MRMatias Rusanen
Matias Rusanen
TKTuomas Karhu
Tuomas Karhu
RHRiku Huttunen
Riku Huttunen
Timo LeppänenTimo Leppänen
Timo Leppänen
SNSami Nikkonen
Sami Nikkonen
The traditional sleep staging involves manual scoring of electroencephalogram (EEG), electrooculogram (EOG), and electromyogram signals during polysomnography (PSG), which is laborious and susceptible to human errors. Previous studies have explored several automated sleep staging methods utilizing fewer EEG signals, for which deep-learning methods have shown promising results. Despite the availability of various signals and signal combinations in PSGs, the performance of different signal combinations for accurate sleep staging is not fully explored. We hypothesize that various EEG signal combinations will yield comparable performances, thus accurate automatic sleep staging could be achieved with a simplified measurement setup. We aim to identify the optimal EEG and EOG signal combinations for deep learning-based automatic sleep staging. Four EEG signals (F4-M1, C4-M1, O2-M1, and C3-M2) and one EOG signal (E1-M2) from 876 suspected obstructive sleep apnea subjects were studied. A total of 31 deep-learning models were trained utilizing different EEG and EOG signal combinations as input. The classification performance of automatic sleep staging against manual sleep staging was evaluated across five sleep stages. The differences in classification performance among various EEG signal combinations were negligible, with accuracies ranging from 81% to 85% (Cohen's kappa, κ = 0.73-0.78). Incorporating the EOG signal into single EEG configurations improved accuracies by 1-2 percentage points, while the improvements were smaller when combining EOG with multiple EEG signals. The comparable classification performances among various signal combinations suggest that automatic sleep staging can be achieved with a simplified EEG and EOG measurement setup without compromising performance.