24 September 2015 in Strahlentherapie und Onkologie
Purpose The aim of this work was to compare and validate various computed tomography (CT) number calibration techniques with respect to cone beam CT (CBCT) dose calculation accuracy. Methods CBCT dose calculation accuracy was assessed for pelvic, lung, and head and neck (H&N) treatment sites for two approaches: (1) physics-based scatter correction methods (CBCTr); (2) density override approaches including assigning water density to the entire CBCT (W), assignment of either water or bone density (WB), and assignment of either water or lung density (WL). Methods for CBCT density assignment within a commercially available treatment planning system (RSauto), where CBCT voxels are binned into six density levels, were assessed and validated. Dose-difference maps and dose-volume statistics were used to compare the CBCT dose distributions with the ground truth of a planning CT acquired the same day as the CBCT. Results For pelvic cases, all CTN calibration methods resulted in average dose-volume deviations below 1.5 %. RSauto provided larger than average errors for pelvic treatments for patients with large amounts of adipose tissue. For H&N cases, all CTN calibration methods resulted in average dose-volume differences below 1.0 % with CBCTr (0.5 %) and RSauto (0.6 %) performing best. For lung cases, WL and RSauto methods generated dose distributions most similar to the ground truth. Conclusion The RSauto density override approach is an attractive option for CTN adjustments for a variety of anatomical sites. RSauto methods were validated, resulting in dose calculations that were consistent with those calculated on diagnostic-quality CT images, for CBCT images acquired of the lung, for patients receiving pelvic RT in cases without excess adipose tissue, and for H&N cases.
1 September 2019 in Clinical and Translational Radiation Oncology
External beam radiotherapy for prostate cancer is an optimal treatment choice for men with localised prostate cancer and is associated with long term disease control in most patients. Image-guided prostate radiotherapy is standard of care, however, current techniques can include invasive procedures with imaging of poor soft tissue resolution, thus limiting accuracy. MRI is the imaging of choice for local prostate cancer staging and in radiotherapy planning has been shown to reduce target volume and reduce inter-observer prostate contouring variability. The ultimate aim would be to have a MR-only workflow for prostate radiotherapy. Within this article, we discuss these opportunities and challenges, relevant due to the increasing availability of MR-guided radiotherapy. Prospective multi-centre studies are underway to determine the feasibility of MR-guided prostate radiotherapy and daily adaptive replanning. In parallel, development and adaptation of the existing radiotherapy multidisciplinary workforce is essential to enable an efficient and effective MR-guided radiotherapy workflow. This technology potentially provides us with the anatomical and biological information to further improve outcomes for our patients.
1 March 2020 in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
To report a planned analysis of the efficacy and toxicity of dose escalation to the intraprostatic dominant nodule identified on multiparametric magnetic resonance imaging using standard and hypofractionated external beam radiation therapy. DELINEATE is a single centre prospective phase 2 multicohort study including standard (cohort A: 74 Gy in 37 fractions) and moderately hypofractionated (cohort B: 60 Gy in 20 fractions) prostate image guided intensity modulated radiation therapy in patients with National Comprehensive Cancer Network intermediate- and high-risk disease. Patients received an integrated boost of 82 Gy (cohort A) and 67 Gy (cohort B) to lesions visible on multiparametric magnetic resonance imaging. Fifty-five patients were treated in cohort A, and 158 patients were treated in cohort B; the first 50 sequentially treated patients in cohort B were included in this planned analysis. The primary endpoint was late Radiation Therapy Oncology Group rectal toxicity at 1 year. Secondary endpoints included acute and late toxicity measured with clinician- and patient-reported outcomes at other time points and biochemical relapse-free survival for cohort A. Median follow-up was 74.5 months for cohort A and 52.0 months for cohort B. In cohorts A and B, 27% and 40% of patients, respectively, were classified as having National Comprehensive Cancer Network high-risk disease. The cumulative 1-year incidence of Radiation Therapy Oncology Group grade 2 or worse rectal and urinary toxicity was 3.6% and 0% in cohort A and 8% and 10% in cohort B, respectively. There was no reported late grade 3 rectal toxicity in either cohort. Within cohort A, 4 of 55 (7%) patients had biochemical relapse. Delivery of a simultaneous integrated boost to intraprostatic dominant nodules is feasible in prostate radiation therapy using standard and moderately hypofractionated regimens, with rectal and genitourinary toxicity comparable to contemporary series without an intraprostatic boost.
1 January 2020 in Radiotherapy and Oncology
Image-guided radiotherapy (IGRT) improves treatment set-up accuracy and provides the opportunity to reduce target volume margins. We introduced IGRT methods using standard (IGRT-S) or reduced (IGRT-R) margins in a randomised phase 2 substudy within CHHiP trial. We present a pre-planned analysis of the impact of IGRT on dosimetry and acute/late pelvic side effects using gastrointestinal and genitourinary clinician and patient-reported outcomes (PRO) and evaluate efficacy. CHHiP is a randomised phase 3, non-inferiority trial for men with localised prostate cancer. 3216 patients were randomly assigned to conventional (74 Gy in 2 Gy/fraction (f) daily) or moderate hypofractionation (60 or 57 Gy in 3 Gy/f daily) between October 2002 and June 2011. The IGRT substudy included a second randomisation assigning to no-IGRT, IGRT-S (standard CTV-PTV margins), or IGRT-R (reduced CTV-PTV margins). Primary substudy endpoint was late RTOG bowel and urinary toxicity at 2 years post-radiotherapy. Between June 2010 to July 2011, 293 men were recruited from 16 centres. Median follow-up is 56.9(IQR 54.3-60.9) months. Rectal and bladder dose-volume and surface percentages were significantly lower in IGRT-R compared to IGRT-S group; (p < 0.0001). Cumulative proportion with RTOG grade ≥ 2 toxicity reported to 2 years for bowel was 8.3(95% CI 3.2-20.7)%, 8.3(4.7-14.6)% and 5.8(2.6-12.4)% and for urinary 8.4(3.2-20.8)%, 4.6(2.1-9.9)% and 3.9(1.5-9.9)% in no IGRT, IGRT-S and IGRT-R groups respectively. In an exploratory analysis, treatment efficacy appeared similar in all three groups. Introduction of IGRT was feasible in a national randomised trial and IGRT-R produced dosimetric benefits. Overall side effect profiles were acceptable in all groups but lowest with IGRT and reduced margins. 97182923.
3 January 2023 in Radiotherapy and Oncology
The implementation of MRI-guided online adaptive radiotherapy has facilitated the extension of therapeutic radiographers’ roles to include contouring, thus releasing the clinician from attending daily treatment. Following undergoing a specifically designed training programme, an online interobserver variability study was performed. 117 images from six patients treated on a MR Linac were contoured online by either radiographer or clinician and the same images contoured offline by the alternate profession. Dice similarity coefficient (DSC), mean distance to agreement (MDA), Hausdorff distance (HD) and volume metrics were used to analyse contours. Additionally, the online radiographer contours and optimised plans (n = 59) were analysed using the offline clinician defined contours. After clinical implementation of radiographer contouring, target volume comparison and dose analysis was performed on 20 contours from five patients. Comparison of the radiographers’ and clinicians’ contours resulted in a median (range) DSC of 0.92 (0.86 – 0.99), median (range) MDA of 0.98 mm (0.2–1.7) and median (range) HD of 6.3 mm (2.5–11.5) for all 117 fractions. There was no significant difference in volume size between the two groups. Of the 59 plans created with radiographer online contours and overlaid with clinicians’ offline contours, 39 met mandatory dose constraints and 12 were acceptable because 95 % of the high dose PTV was covered by 95 % dose, or the high dose PTV was within 3 % of online plan. A clinician blindly reviewed the eight remaining fractions and, using trial quality assurance metrics, deemed all to be acceptable. Following clinical implementation of radiographer contouring, the median (range) DSC of CTV was 0.93 (0.88–1.0), median (range) MDA was 0.8 mm (0.04–1.18) and HD was 5.15 mm (2.09–8.54) respectively. Of the 20 plans created using radiographer online contours overlaid with clinicians’ offline contours, 18 met the dosimetric success criteria, the remaining 2 were deemed acceptable by a clinician. Radiographer and clinician prostate and seminal vesicle contours on MRI for an online adaptive workflow are comparable and produce clinically acceptable plans. Radiographer contouring for prostate treatment on a MR-linac can be effectively introduced with appropriate training and evaluation. A DSC threshold for target structures could be implemented to streamline future training.
1 December 2019 in Radiotherapy and Oncology