Sophie Le Cann

Sophie Le Cann

Auto-generated profile, based on publicly available information

Sophie Le Cann

Department of Biomedical Engineering, Lund University, Lund, Sweden

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MTMikael Turunen
Mikael Turunen
SCSophie Le Cann
Sophie Le Cann
ETErika Tudisco
Erika Tudisco
GLGoran Lovric
Goran Lovric
APAlessandra Patera
Alessandra Patera
HIHanna Isaksson
Hanna Isaksson
To comprehend the most detrimental characteristics behind bone fractures, it is key to understand the material and tissue level strain limits and their relation to failure sites. The aim of this study was to investigate the three-dimensional strain distribution and its evolution during loading at the sub-trabecular level in trabecular bone tissue. Human cadaver trabecular bone samples were compressed in situ until failure, while imaging with high-resolution synchrotron radiation X-ray tomography. Digital volume correlation was used to determine the strains inside the trabeculae. Regions without emerging damage were compared to those about to crack. Local strains in close vicinity of developing cracks were higher than previously reported for a whole trabecular structure and similar to those reported for single isolated trabeculae. Early literature on bone fracture strain thresholds at the tissue level seem to underestimate the maximum strain magnitudes in trabecular bone. Furthermore, we found lower strain levels and a reduced ability to capture detailed crack-paths with increased image voxel size. This highlights the dependence between the observed strain levels and the voxel size and that high-resolution is needed to investigate behavior of individual trabeculae. Furthermore, low trabecular thickness appears to be one predictor of developing cracks. In summary, this study investigated the local strains in whole trabecular structure at sub-trabecular resolution in human bone and confirmed the high strain magnitudes reported for single trabeculae under loading and, importantly extends its translation to the whole trabecular structure.

1 November 2017 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
SCSophie Le Cann
Sophie Le Cann
ETErika Tudisco
Erika Tudisco
CPChristina Perdikouri
Christina Perdikouri
OBOla Belfrage
Ola Belfrage
Anders KaestnerAnders Kaestner
Anders Kaestner
HIHanna Isaksson
Hanna Isaksson

9 July 2013 in International Orthopaedics
Verified
Journal Article
Closed access
PDF file
AGAlexandre Galland
Alexandre Galland
SAStéphane Airaudi
Stéphane Airaudi
RGRenaud Gravier
Renaud Gravier
SCSophie Le Cann
Sophie Le Cann
PCPatrick Chabrand
Patrick Chabrand
JAJean-Noël Argenson
Jean-Noël Argenson

1 October 2017 in Bone
Verified
Journal Article
Closed access
HIHanna Isaksson
Hanna Isaksson
SCSophie Le Cann
Sophie Le Cann
CPChristina Perdikouri
Christina Perdikouri
MTMikael Turunen
Mikael Turunen
Anders KaestnerAnders Kaestner
Anders Kaestner
ETErika Tudisco
Erika Tudisco

12 January 2012 in Soft Matter
Verified
Journal Article
Closed access
PDF file
CCCharlotte E. Conn
Charlotte E. Conn
Connie DarmaninConnie Darmanin
Connie Darmanin
XMXavier Mulet
Xavier Mulet
SCSophie Le Cann
Sophie Le Cann
NKNigel Kirby
Nigel Kirby
CDCalum John Drummond
Calum John Drummond
We have tracked the structural evolution of the monoolein bicontinuous cubic phase under in meso crystallogenesis conditions. Significantly, all measurements have been carried out in situ within a crystallisation plate reproducing the exact conditions during a crystallisation trial. The structure of the MO cubic phase, doped with a small concentration of amyloid-beta peptide, was measured 1 day, 5 days, 7 days and 21 days after addition of PACT crystallisation screen, which systematically varies cation, anion, pH and polyethylene glycol (PEG). The components of the screen had a significant impact on the structure of the cubic phase. We have rationalised the structural variation with respect to the effect of the individual screen components. Specifically addition of higher Mw PEG effected a transition from a diamond cubic phase (QII D) to a gyroid cubic phase (QII G) across the majority of the plate and the QII G phase became more prevalent with time. The effect of individual salts was correlated with their position in the Hofmeister series. Changes in pH and buffer system had a more minor effect on mesophase structure. We have discussed the implications of the observed structural changes with respect to the putative mechanism of protein crystal growth within a lipidic cubic phase.

28 July 2014 in Medical Engineering & Physics
Verified
Journal Article
Closed access
SCSophie Le Cann
Sophie Le Cann
AGAlexandre Galland
Alexandre Galland
BRBenoît Rosa
Benoît Rosa
TCThomas Le Corroller
Thomas Le Corroller
Martine PithiouxMartine Pithioux
Martine Pithioux
SPSébastien Parratte
Sébastien Parratte
Most acetabular cups implanted today are press-fit impacted cementless. Anchorage begins with the primary stability given by insertion of a slightly oversized cup. This primary stability is key to obtaining bone ingrowth and secondary stability. We tested the hypothesis that primary stability of the cup is related to surface roughness of the implant, using both an experimental and a numerical models to analyze how three levels of surface roughness (micro, macro and combined) affect the primary stability of the cup. We also investigated the effect of differences in diameter between the cup and its substrate, and of insertion force, on the cups' primary stability. The results of our study show that primary stability depends on the surface roughness of the cup. The presence of macro-roughness on the peripheral ring is found to decrease primary stability; there was excessive abrasion of the substrate, damaging it and leading to poor primary stability. Numerical modeling indicates that oversizing the cup compared to its substrate has an impact on primary stability, as has insertion force.