Zhimi Zhang

Zhimi Zhang

Auto-generated profile, based on publicly available information

Zhimi Zhang

School of Medicine, University of Electronic Science and Technology of China, Chengdu, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2023 in Measurement Science and Technology
Verified
Journal Article
Closed access
ZPZhen Peng
Zhen Peng
ZLZongyuan Li
Zongyuan Li
JLJingru Liao
Jingru Liao
ZZZhimi Zhang
Zhimi Zhang
YSYangyang Song
Yangyang Song
Zhuqing WangZhuqing Wang
Zhuqing Wang
A highly electroactive bilayer composite film sensing interface of Prussian blue (PB)/gold nanoparticles-chitosan (AuNPs-CS) was modified on Au electrode through electrochemical deposition and coating method followed by integrating glucose oxidase (GOx) into the interfacial matrix to fabricate a high-performance glucose biosensor. The excellent electrocatalytic ability of the PB/AuNPs-CS composite film sensing interface for H2O2 was evaluated, which has a broad linear response of 0.01–7.95 mM, with a low detection limit (LOD) 0.269 μM and a high sensitivity of 511.82 μA·mM−1·cm−2. The enhanced electrocatalytic activity of this sensing interface for H2O2 is attributed to the protection from the network CS film to PB and the synergistic effect of PB and AuNPs. Consequently, an electrochemical biosensing interface was constructed with GOx immobilized as a model enzyme. The PB/GOx-AuNPs-CS biosensing nanocomposite film was capable of a fast steady-state response time (within 2 s) and high sensitivity to glucose with a wide linear range of: 0.025–2.00 mM (R 2 = 0.99), with a sensitivity of 40.41 μA·mM−1·cm−2 and a LOD of 1.62 μM; and 2.00–6.50 mM (R 2 = 0.98), with a sensitivity of 8.90 μA·mM−1·cm−2 and a LOD of 7.16 μM. The biosensor has good anti-interference and selectivity, which provides a promising wide linear range platform for clinical blood glucose detection in the future.

1 April 2025 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
ZPZhen Peng
Zhen Peng
ZZZhimi Zhang
Zhimi Zhang
ZHZiyi He
Ziyi He
Adrian TeoAdrian Teo
Adrian Teo
YLYihao Long
Yihao Long
Holden LiHolden Li
Holden Li
Cell lysis is fundamental yet crucial for downstream bioassays. The use of chemical reagents will directly affect the subsequent workflows. Important research involving microfluidics is emerging in cell lysis, for its merits in less reagent usage and high automation of agent manipulation. In this study, a novel microfluidic system was designed and validated in achieving the synergistic effect of mechanical and chemical lysis. The consumption of cell lysis reagent is reduced by half without compromising lysis efficiency. A PDMS-based microfluidic system with a magnetically driven stirring bar enhances cell lysis through mechanical agitation. The lysed cell sample can be centrifuged into the detection chamber for observation. Experiments conducted using oral CAL-27 adenosquamous carcinoma cells showed that the mechanical shock generated in situ had a positive synergistic effect on chemical cell lysing, further optimizing traditional lysing procedures. The maximum cell lysis efficiency was improved from 88% to 94% while reducing the use of reagents. Critical parameters also enable similar lysis efficiencies at half the dosage required. This microfluidic system can enable on-site biological sample preparation for point-of-care detection, offering significant cost and time savings while ensuring high efficiency and reliability.[2025-0012]