Charles J. Stark

Charles J. Stark

Auto-generated profile, based on publicly available information

Charles J. Stark

Department of Cardiothoracic Surgery, Stanford University School of Medicine, Falk Cardiovascular Research Center, 300 Pasteur Drive, Stanford, CA 94305, USA

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2024 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
YZYuanjia Zhu
Yuanjia Zhu
SYShin Yajima
Shin Yajima
MPMatthew H. Park
Matthew H. Park
AVAkshay Venkatesh
Akshay Venkatesh
CSCharles J. Stark
Charles J. Stark
YWY. Joseph Woo
Y. Joseph Woo
BACKGROUND: Various mitral repair techniques have been described. Though these repair techniques can be highly effective when performed correctly in suitable patients, limited quantitative biomechanical data are available. Validation and thorough biomechanical evaluation of these repair techniques from translational large animal in vivo studies in a standardized, translatable fashion are lacking. We sought to evaluate and validate biomechanical differences among different mitral repair techniques and further optimize repair operations using a large animal mitral valve prolapse model. METHODS: Male Dorset sheep (n=20) had P2 chordae severed to create the mitral valve prolapse model. Fiber Bragg grating force sensors were implanted to measure chordal forces. Ten sheep underwent 3 randomized, paired mitral valve repair operations: neochord repair, nonresectional leaflet remodeling, and triangular resection. The other 10 sheep underwent neochord repair with 2, 4, and 6 neochordae. Data were collected at baseline, mitral valve prolapse, and after each repair. RESULTS: All mitral repair techniques successfully eliminated regurgitation. Compared with mitral valve prolapse (0.54±0.18 N), repair using neochord (0.37±0.20 N; P =0.02) and remodeling techniques (0.30±0.15 N; P =0.001) reduced secondary chordae peak force. Neochord repair further decreased primary chordae peak force (0.21±0.14 N) to baseline levels (0.20±0.17 N; P =0.83), and was associated with lower primary chordae peak force compared with the remodeling (0.34±0.18 N; P =0.02) and triangular resectional techniques (0.36±0.27 N; P =0.03). Specifically, repair using 2 neochordae resulted in higher peak primary chordal forces (0.28±0.21 N) compared with those using 4 (0.22±0.16 N; P =0.02) or 6 neochordae (0.19±0.16 N; P =0.002). No difference in peak primary chordal forces was observed between 4 and 6 neochordae ( P =0.05). Peak forces on the neochordae were the lowest using 6 neochordae (0.09±0.11 N) compared with those of 4 neochordae (0.15±0.14 N; P =0.01) and 2 neochordae (0.29±0.18 N; P =0.001). CONCLUSIONS: Significant biomechanical differences were observed underlying different mitral repair techniques in a translational large animal model. Neochord repair was associated with the lowest primary chordae peak force compared to the remodeling and triangular resectional techniques. Additionally, neochord repair using at least 4 neochordae was associated with lower chordal forces on the primary chordae and the neochordae. This study provided key insights about mitral valve repair optimization and may further improve repair durability.

22 July 2025 in The Journal of Physiology
Verified
Journal Article
Open access
CSCharles Stark
Charles Stark
EREric Rytkin
Eric Rytkin
AMAndrei Alexandru Mircea
Andrei Alexandru Mircea
IEIgor Efimov
Igor Efimov
Diagnostic bioelectronics such as the electrocardiogram have become increasingly prevalent in the management of cardiovascular diseases like atrial fibrillation. While these devices provide meaningful clinical value, their complex and profuse data output requires considerable labour and training from clinicians to diagnose disease. This abundant production of complex data has made diagnostic bioelectronics a prime target for artificial intelligence (AI) integration. AI‐integrated diagnostic bioelectronics have already left the clinic as widely prevalent wearable smartwatches equipped with single‐lead electrocardiography sensors. Meanwhile, substantial innovation is also taking place at the intersection of other sensing modalities in the form of edge computing. Here, we overview the implementation and embedding of AI into diagnostic bioelectronics of multiple sensing modalities, including electrocardiography, photoplethysmography, echocardiography, and others, and discuss the recent advances made by medical device companies and researchers alike at the interface between the heart and AI. image

27 November 2025 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
CWCatherine A. Wu
Catherine A. Wu
YZYuanjia Zhu
Yuanjia Zhu
CSCharles J. Stark
Charles J. Stark
SLSeung Hyun Lee
Seung Hyun Lee
CHChris Huynh
Chris Huynh
YWY. Joseph Woo
Y. Joseph Woo
The field of tissue engineering has been an ever-evolving discipline with a principal direction of creating artificial constructs to improve biological tissue types.