Cardiovascular diseases are the leading cause of morbidity and mortality in the United States. Cardiac tissue engineering is a direction in regenerative medicine that aims to repair various heart defects with the long-term goal of artificially rebuilding a full-scale organ that matches its native structure and function. Three-dimensional (3D) bioprinting offers promising applications through its layer-by-layer biomaterial deposition using different techniques and bio-inks. In this review, we will introduce cardiac tissue engineering, 3D bioprinting processes, bioprinting techniques, bio-ink materials, areas of limitation, and the latest applications of this technology, alongside its future directions for further innovation.
Newborn mice and piglets exhibit natural heart regeneration after myocardial infarction (MI). Discovering other mammals with this ability would provide evidence that neonatal cardiac regeneration after MI may be a conserved phenotype, which if activated in adults could open new options for treating ischemic cardiomyopathy in humans. Here, we hypothesized that newborn rats undergo natural heart regeneration after MI. Using a neonatal rat MI model, we performed left anterior descending coronary artery ligation or sham surgery in one-day-old rats under hypothermic circulatory arrest (n = 74). Operative survival was 97.3%. At 1 day post-surgery, rats in the MI group exhibited significantly reduced ejection fraction (EF) compared to shams (87.1% vs. 53.0%, p < 0.0001). At 3 weeks post-surgery, rats in the sham and MI groups demonstrated no difference in EF (71.1% vs. 69.2%, respectively, p = 0.2511), left ventricular wall thickness (p = 0.9458), or chamber diameter (p = 0.7801). Masson’s trichome and picrosirius red staining revealed minimal collagen scar after MI. Increased numbers of cardiomyocytes positive for 5-ethynyl-2′-deoxyuridine (p = 0.0072), Ki-67 (p = 0.0340), and aurora B kinase (p = 0.0430) were observed within the peri-infarct region after MI, indicating ischemia-induced cardiomyocyte proliferation. Overall, we present a neonatal rat MI model and demonstrate that newborn rats are capable of endogenous neocardiomyogenesis after MI.
Extrusion-based three-dimensional (3D) bioprinting is an emerging technology that allows for rapid bio-fabrication of scaffolds with live cells. Alginate is a soft biomaterial that has been studied extensively as a bio-ink to support cell growth in 3D constructs. However, native alginate is a bio-inert material that requires modifications to allow for cell adhesion and cell growth. Cells grown in modified alginates with the RGD (arginine-glycine-aspartate) motif, a naturally existing tripeptide sequence that is crucial to cell adhesion and proliferation, demonstrate enhanced cell adhesion, spreading, and differentiation. Recently, the bioprinting technique using freeform reversible embedding of suspended hydrogels (FRESH) has revolutionized 3D bioprinting, enabling the use of soft bio-inks that would otherwise collapse in air. However, the printability of RGD-modified alginates using the FRESH technique has not been evaluated. The associated physical properties and bioactivity of 3D bio-printed alginates after RGD modification remains unclear. In this study, we characterized the physical properties, printability, and cellular proliferation of native and RGD-modified alginate after extrusion-based 3D bioprinting in FRESH. We demonstrated tunable physical properties of native and RGD-modified alginates after FRESH 3D bioprinting. Sodium alginate with RGD modification, especially at a high concentration, was associated with greatly improved cell viability and integrin clustering, which further enhanced cell proliferation.
Aims : Since 1968, heart transplantation has become the definitive treatment for patients with end-stage heart failure. We aimed to summarize our experience in heart transplantation at Stanford University since the first transplantation performed over 50 years ago. Methods and results : From 6 January 1968 to 30 November 2020, 2671 patients presented to Stanford University for heart transplantation, of which 1958 were adult heart transplantations. Descriptive analyses were performed for patients in 1968–95 (n = 639). Stabilized inverse probability weighting was applied to compare patients in 1996–2006 (n = 356) vs. 2007–19 (n = 515). Follow-up data were updated through 2020. The primary endpoint was all-cause mortality. Prior to weighting, recipients in 2007–19 vs. those in 1996–2006 were older and had heavier burden of chronic diseases. After the application of stabilized inverse probability weighting, the distance organ travelled increased from 84.2 ± 111.1 miles to 159.3 ± 169.9 miles from 1996–2006 to 2007–19. Total allograft ischaemia time also increased over time (199.6 ± 52.7 vs. 225.3 ± 50.0 min). Patients in 2007–19 showed superior survival than those in 1996–2006 with a median survival of 12.1 vs. 11.1 years. Conclusion : In this half-century retrospective descriptive study from one of the largest heart transplant programmes in the USA, long-term survival after heart transplantation has improved over time despite increased recipient and donor age, worsening comorbidities, increased technical complexity, and prolonged total allograft ischaemia time. Further investigation is warranted to delineate factors associated with the excellent outcomes observed in this study.
The need for personal protective equipment during the COVID-19 pandemic is far outstripping our ability to manufacture and distribute these supplies to hospitals. In particular, the medical N95 mask shortage is resulting in healthcare providers reusing masks or utilizing masks with filtration properties that do not meet medical N95 standards. We developed a solution for immediate use: a mask adaptor, outfitted with a quarter section of an N95 respirator that maintains the N95 seal standard, thereby quadrupling the N95 supply. A variety of designs were 3D-printed and optimized based on the following criteria: seal efficacy, filter surface area and N95 respirator multiplicity. The final design is reusable and features a 3D-printed soft silicone base as well as a rigid 3D-printed cartridge to seal one-quarter of a 3M 1860 N95 mask. Our mask passed the computerized N95 fit test for six individuals. All files are publicly available with this publication. Our design can provide immediate support for healthcare professionals in dire need of medical N95 masks by extending the current supply by a factor of four.
1 April 2024 in Circulation: Cardiovascular Interventions
BACKGROUND: Various mitral repair techniques have been described. Though these repair techniques can be highly effective when performed correctly in suitable patients, limited quantitative biomechanical data are available. Validation and thorough biomechanical evaluation of these repair techniques from translational large animal in vivo studies in a standardized, translatable fashion are lacking. We sought to evaluate and validate biomechanical differences among different mitral repair techniques and further optimize repair operations using a large animal mitral valve prolapse model. METHODS: Male Dorset sheep (n=20) had P2 chordae severed to create the mitral valve prolapse model. Fiber Bragg grating force sensors were implanted to measure chordal forces. Ten sheep underwent 3 randomized, paired mitral valve repair operations: neochord repair, nonresectional leaflet remodeling, and triangular resection. The other 10 sheep underwent neochord repair with 2, 4, and 6 neochordae. Data were collected at baseline, mitral valve prolapse, and after each repair. RESULTS: All mitral repair techniques successfully eliminated regurgitation. Compared with mitral valve prolapse (0.54±0.18 N), repair using neochord (0.37±0.20 N; P =0.02) and remodeling techniques (0.30±0.15 N; P =0.001) reduced secondary chordae peak force. Neochord repair further decreased primary chordae peak force (0.21±0.14 N) to baseline levels (0.20±0.17 N; P =0.83), and was associated with lower primary chordae peak force compared with the remodeling (0.34±0.18 N; P =0.02) and triangular resectional techniques (0.36±0.27 N; P =0.03). Specifically, repair using 2 neochordae resulted in higher peak primary chordal forces (0.28±0.21 N) compared with those using 4 (0.22±0.16 N; P =0.02) or 6 neochordae (0.19±0.16 N; P =0.002). No difference in peak primary chordal forces was observed between 4 and 6 neochordae ( P =0.05). Peak forces on the neochordae were the lowest using 6 neochordae (0.09±0.11 N) compared with those of 4 neochordae (0.15±0.14 N; P =0.01) and 2 neochordae (0.29±0.18 N; P =0.001). CONCLUSIONS: Significant biomechanical differences were observed underlying different mitral repair techniques in a translational large animal model. Neochord repair was associated with the lowest primary chordae peak force compared to the remodeling and triangular resectional techniques. Additionally, neochord repair using at least 4 neochordae was associated with lower chordal forces on the primary chordae and the neochordae. This study provided key insights about mitral valve repair optimization and may further improve repair durability.