Xinlin Chen

Xinlin Chen

Auto-generated profile, based on publicly available information

Xinlin Chen

Institute of Lasers and Biomedical Photonics, Biomedical Engineering College, Wenzhou Medical University, Wenzhou, Zhejiang, 325035, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2017 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
XCXinlin Chen
Xinlin Chen
WLWeihao Lin
Weihao Lin
CWChenge Wang
Chenge Wang
SCShaoheng Chen
Shaoheng Chen
JSJing Sheng
Jing Sheng
MXMin Xu
Min Xu
We present the real-time single snapshot multiple frequency demodulation - spatial frequency domain imaging (SSMD-SFDI) platform implemented with a visible digital mirror device that is capable of imaging and monitoring dynamic turbid medium and processes over a large field of view. One challenge in quantitative imaging of biological tissue such as the skin is the complex structure rendering techniques based on homogeneous medium models to fail. To address this difficulty we have also developed a novel method that maps the layered structure to a homogeneous medium for spatial frequency domain imaging. The varying penetration depth of spatially modulated light on its wavelength and modulation frequency is used to resolve the layered structure. The efficacy of the real-time SSMD-SFDI platform and this two-layer model is demonstrated by imaging forearms of 6 healthy subjects under the reactive hyperemia protocol. The results show that our approach not only successfully decouples light absorption by melanin from that by hemoglobin and yields accurate determination of cutaneous hemoglobin concentration and oxygen saturation, but also provides reliable estimation of the scattering properties, the melanin content and the epidermal thickness in real time. Potential applications of our system in imaging skin physiological and functional states, cancer screening, and microcirculation monitoring are discussed at the end.

4 June 2018 in Biomedical Optics Express
Verified
Journal Article
Closed access
PDF file
WLWeihao Lin
Weihao Lin
BZBixin Zeng
Bixin Zeng
ZCZili Cao
Zili Cao
XCXinlin Chen
Xinlin Chen
KYKaiyan Yang
Kaiyan Yang
MXMin Xu
Min Xu
Non-contact and minimally invasive endoscopic optical imaging is an invaluable diagnostic tool for tissue examination and cancer screening. The point sampling techniques with high sensitivity to the tissue microenvironment are time consuming and often not affordable in clinics. There is a major clinical need for a large field-of-view (FOV) rapid screening method to highlight subtle tissue microstructural alterations. To address this unmet need, we have developed High Spatial Frequency Domain Imaging (HSFDI)–a non-contact imaging modality that spatially maps the tissue microscopic scattering structures over a large field of view (>1cm2). Based on an analytical reflectance model of sub-diffusive light from forward-peaked highly scattering media, HSFDI quantifies the spatially-resolved parameters of the light scattering phase function (i.e., the backscattering probability and the light spreading length) from the reflectance of structured light modulated at high spatial frequencies. Enhanced signal to noise ratio (SNR) is achieved at even ultra-high modulation frequencies with single snapshot multiple frequency demodulation (SSMD). The variations in tissue microstructures, including the strength of the background (pudding) refractive index fluctuation and the prominent scattering structure (plum) morphology, can then be inferred. After validation with optical phantoms, measurements of fresh ex vivo tissue samples revealed significant contrast and differentiation of the phase function parameters between different types and disease states (normal, inflammatory, and cancerous) of tissue whereas tissue absorption and reduced scattering coefficients only show modest changes. HSFDI may provide wide-field images of microscopic structural biomarkers unobtainable with either diffuse light imaging or point-based optical sampling. Potential clinical applications include the rapid screening of excised tissue and the noninvasive examination of suspicious lesions during operation.

24 July 2020 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
MXMin Xu
Min Xu
YZYang Zheng
Yang Zheng
XCXinlin Chen
Xinlin Chen
YLYing Li
Ying Li
WLWeihao Lin
Weihao Lin
BZBixin Zeng
Bixin Zeng
We present a dynamic microcirculation PIPE model for functional neuroimaging, non-neuroimaging, and coherent hemodynamics spectroscopy. The temporal evolution of the concentration and oxygen saturation of hemoglobin in tissue, comprised of the contributions from the arterioles, capillaries, and venules of microvasculature, is determined by time-resolved hemodynamic and metabolic variations in blood volume, flow velocity, and oxygen consumption with a fluid mechanics treatment. Key parameters regarding microcirculation can be assessed, including the effective blood transit times through the capillaries and the venules, and the rate constant of oxygen release from hemoglobin to tissue. The vascular autoregulation can further be quantified from the relationship between the resolved blood volume and flow velocity variations. The PIPE model shows excellent agreement with the experimental cerebral and cutaneous coherent hemodynamics spectroscopy (CHS) and fMRI-BOLD data. It further identifies the impaired cerebral autoregulation distinctively in hemodialysis patients compared to healthy subjects measured by CHS. This new dynamic microcirculation PIPE model provides a valuable tool for brain and other functional studies with hemodynamic-based techniques. It is instrumental in recovering physiological parameters from analyzing and interpreting the signals measured by hemodynamic-based neuroimaging and non-neuroimaging techniques such as functional near-infrared spectroscopy (fNIRS) and functional magnetic resonance imaging (fMRI) in response to brain activation, physiological challenges, or physical maneuvers.

7 February 2018 in Optik
Verified
Journal Article
Open access
PDF file
GXGuangzong Xiao
Guangzong Xiao
XHXiang Han
Xiang Han
XCXinlin Chen
Xinlin Chen
KYKaiyong Yang
Kaiyong Yang
HLHui Luo
Hui Luo
We have fully investigated the integrated lensing effect that the beam suffers in a dual-fiber optical trap. A modified model for coupling of a beam to the opposing fiber has been built in consideration of the integrated lensing effect. We discussed the effect of z-axial position, radius and refractive index of the trapped sphere on the coupling efficiency using the modified coupling coefficient model. The measured and calculated coupling efficiency as a function of z-axial position have the same tendency in the allowable error. Comparison among above simulation and experiment has made clear that the magnitude relation between the smallest spot size and the mode field radius decide whether the spot size matching or wavefront phase matching dominate the coupling coefficient. What’s more, we point out that the dependence of relative coupling coefficient on the refractive index has knee point. That is an obstacle to the application of single live cell refractive index measurement method based on lensing effect. Nevertheless, this method is absorbing and promising because there is a linear range for the known experimental parameters in an optical trap, and it needs no additional accessory.

24 October 2022 in Optics Letters
Verified
Journal Article
Closed access
PDF file
HCHui Cheng
Hui Cheng
XCXinLin Chen
XinLin Chen
JZJinCheng Zhong
JinCheng Zhong
JLJia Li
Jia Li
PQPing Qiu
Ping Qiu
KWKe Wang
Ke Wang
Wall shear stress (WSS) is of fundamental physiological and pathological significance. Current measurement technologies suffer from poor spatial resolution or cannot measure instantaneous values in a label-free manner. Here we demonstrate dual-wavelength third-harmonic-generation (THG) line-scanning imaging, for instantaneous wall shear rate and WSS measurement in vivo. We used the soliton self-frequency shift to generate dual-wavelength femtosecond pulses. Simultaneous acquisition of dual-wavelength THG line-scanning signals extract blood flow velocities at adjacent radial positions for instantaneous wall shear rate and WSS measurement. Our results show the oscillating behavior of WSS in brain venules and arterioles at micron spatial resolution in a label-free manner.

20 October 2021 in Optics Letters
Verified
Journal Article
Closed access
ZLZijie Liu
Zijie Liu
TKTengfang Kuang
Tengfang Kuang
WXWei Xiong
Wei Xiong
HFHaining Feng
Haining Feng
XCXinlin Chen
Xinlin Chen
HLHui Luo
Hui Luo
The intracavity optical tweezers is a new, to the best of our knowledge, cavity optomechanics system, implementing a self-feedback control of the particle’s position by trapping the particle inside an active ring cavity. This self-feedback mechanism efficiently constructs a novel potential in the cavity. Here we predict and give experimental evidence for the self-feedback induced optical bistability in dual-beam intracavity optical tweezers. Then the characteristics of these bistable potential wells are investigated. The results show that we can prevent the bistable behaviors from destabilizing the trapping stability through tuning the foci offset of two propagating beams in the cavity. This contributes to the use of intracavity optical tweezers as a powerful tool for optical manipulation. Importantly, the thermally activated transition of the trapped particle in the bistable potential is observed for particular experimental parameters. Further investigation of this phenomenon could underlie the mechanism of many metastable-related processes in physics, chemistry, and biology.