Runze Li

Runze Li

Auto-generated profile, based on publicly available information

Runze Li

School of Electrical Engineering, Henan University of Technology, Zhengzhou, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 November 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
QNQunfeng Niu
Qunfeng Niu
RLRunze Li
Runze Li
SLShuxiang Lin
Shuxiang Lin
SLSonglin Li
Songlin Li
SLShujing Lin
Shujing Lin
LWLi Wang
Li Wang
In the research of linear displacement sensors, the primary focus has been on displacement sensors based on gratings. However, the limitation of grating pitch and the substantial noise inherently present in the original Moiré signals from gratings seriously affect the accuracy of grating displacement sensors. Therefore, this paper proposes a grating displacement measurement method based on Moiré signal reconstruction and arctangent subdivision to improve the accuracy of grating displacement sensors. First, improvements were made to the least mean square (LMS) algorithm and coordinate rotation digital computer (CORDIC) algorithm, which are essential for Moiré signals reconstruction method. Based on these enhanced algorithms, the Moiré signals reconstruction process was developed to improve signal quality, and the arctangent subdivision method was employed to subdivide the Moiré signals. Finally, the effectiveness of the Moiré signal reconstruction method was verified through a built performance test platform for linear displacement sensors, and the accuracy of the linear displacement sensors was tested. Experimental results show that the subdivision errors before and after Moiré signals reconstruction are 1.985 rad and 0.157 rad, respectively. The system's measurement accuracy is within 1 μm, and both repeatability and reproducibility errors are less than 0.6 μm.

13 November 2024 in IEEE Electron Device Letters
Verified
Journal Article
Closed access
SLShuxiang Lin
Shuxiang Lin
STSiyu Tong
Siyu Tong
JNJiaqi Niu
Jiaqi Niu
RLRunze Li
Runze Li
QNQunfeng Niu
Qunfeng Niu
SLShujing Lin
Shujing Lin
Timely detection of abnormal pulse wave conditions can provide early warnings for cardiovascular emergencies. Strain sensors can detect subtle pulse wave changes, however, they often face a trade-off between flexibility and accuracy. Herein, we present a cost-effective, high-sensitivity elastic strain sensor based on foam-structured silicone rubber@nanocarbon black (SR@CB). The sensor exhibits excellent linearity within a strain range of 0-60%, with a detection sensitivity of 0.1% and a gauge factor of up to 32. Thus, it can detect not only subtle pulse wave signals, but also be used for motion monitoring. Moreover, we have developed an elastic circuit detection system prototype, significantly enhancing wearer comfort while achieving a fully elastic detection system. We foresee this fully elastic detection system holds promise for health monitoring and motion detection applications.