Jiaqi Niu

Jiaqi Niu

Auto-generated profile, based on publicly available information

Jiaqi Niu

Institute of Intelligent Health Diagnosis and Treatment, School of Sensing Science and Engineering, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai, 200240, PR China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
ZYZixian Yu
Zixian Yu
SLShujing Lin
Shujing Lin
FXFangfang Xia
Fangfang Xia
YLYanlei Liu
Yanlei Liu
DZDi Zhang
Di Zhang
DCDi Chen
Di Chen

6 November 2023 in Small
Verified
Journal Article
Closed access
JNJiaqi Niu
Jiaqi Niu
SLShujing Lin
Shujing Lin
DCDi Chen
Di Chen
ZWZhitao Wang
Zhitao Wang
CCCheng Cao
Cheng Cao
DCDaxiang Cui
Daxiang Cui

28 July 2022 in Journal of Chromatography A
Verified
Journal Article
Closed access
HTHao Tang
Hao Tang
JNJiaqi Niu
Jiaqi Niu
XPXinni Pan
Xinni Pan
HJHan Jin
Han Jin
SLShujing Lin
Shujing Lin
DCDaxiang Cui
Daxiang Cui

19 July 2024 in Talanta
Verified
Journal Article
Closed access
JNJiaqi Niu
Jiaqi Niu
SLShujing Lin
Shujing Lin
YXYichong Xu
Yichong Xu
STSiyu Tong
Siyu Tong
ZWZhitao Wang
Zhitao Wang
DCDaxiang Cui
Daxiang Cui

13 January 2025 in Materials Today Bio
Verified
Journal Article
Open access
SCShengsheng Cui
Shengsheng Cui
XPXinni Pan
Xinni Pan
SFShanshan Fan
Shanshan Fan
CCCheng Cao
Cheng Cao
YJYingao Jiao
Yingao Jiao
YLYanlei Liu
Yanlei Liu
Photothermal therapy (PTT) utilizes photothermal materials to convert light energy into heat under external light irradiation, effectively killing cancer cells. Therefore, the efficacy of PTT is largely determined by the photothermal conversion efficiency of the material. In this study, we developed a novel ladder-type conjugated polymer, PPAPA, via a phenazine ring fusion reaction. PPAPA exhibits a high photothermal conversion efficiency of 75.2 % under 1064 nm laser irradiation, comparable to the benchmark organic photothermal agent SWCNT. Notably, the synthesis of PPAPA avoids the use of noble metal catalysts, eliminating potential biotoxicity caused by residual catalysts and ensuring optimal photothermal stability and efficiency. Furthermore, PPAPA demonstrates efficient photothermal conversion under near-infrared II (NIR-II) 1064 nm laser irradiation, enabling deeper tissue penetration and reduced tissue absorption. This work comprehensively investigates the photothermal properties of PPAPA and evaluates its efficacy in tumor PTT, demonstrating its potential as a novel and effective therapeutic strategy for cancer treatment, offering new hope for patients.

24 November 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
QNQunfeng Niu
Qunfeng Niu
RLRunze Li
Runze Li
SLShuxiang Lin
Shuxiang Lin
SLSonglin Li
Songlin Li
SLShujing Lin
Shujing Lin
LWLi Wang
Li Wang
In the research of linear displacement sensors, the primary focus has been on displacement sensors based on gratings. However, the limitation of grating pitch and the substantial noise inherently present in the original Moiré signals from gratings seriously affect the accuracy of grating displacement sensors. Therefore, this paper proposes a grating displacement measurement method based on Moiré signal reconstruction and arctangent subdivision to improve the accuracy of grating displacement sensors. First, improvements were made to the least mean square (LMS) algorithm and coordinate rotation digital computer (CORDIC) algorithm, which are essential for Moiré signals reconstruction method. Based on these enhanced algorithms, the Moiré signals reconstruction process was developed to improve signal quality, and the arctangent subdivision method was employed to subdivide the Moiré signals. Finally, the effectiveness of the Moiré signal reconstruction method was verified through a built performance test platform for linear displacement sensors, and the accuracy of the linear displacement sensors was tested. Experimental results show that the subdivision errors before and after Moiré signals reconstruction are 1.985 rad and 0.157 rad, respectively. The system's measurement accuracy is within 1 μm, and both repeatability and reproducibility errors are less than 0.6 μm.