D. Delicato

D. Delicato

Auto-generated profile, based on publicly available information

D. Delicato

Dipartimento di Fisica, Sapienza Università di Roma, P. le A. Moro 2, 00185 Roma

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2025 in Applied Physics Letters
Verified
Journal Article
Closed access
DDD. Delicato
D. Delicato
DAD. Angelone
D. Angelone
LBL. Bandiera
L. Bandiera
MCM. Calvo
M. Calvo
MCM. Cappelli
M. Cappelli
MVM. Vignati
M. Vignati
Cryogenic phonon detectors are adopted in experiments searching for dark matter interactions or coherent elastic neutrino-nucleus scattering, thanks to the low energy threshold they can achieve. The phonon-mediated sensing of particle interactions in passive silicon absorbers has been demonstrated with kinetic inductance detectors (KIDs). Targets with neutron number larger than silicon, however, feature a higher cross section to neutrinos, while multi-target absorbers in the dark matter experiments would provide a stronger evidence of a possible signal. In this work, we present the design, fabrication, and operation of KIDs coupled to a germanium absorber, achieving phonon-sensing performance comparable to silicon absorbers. The device introduced in this work is a proof of concept for a scalable neutrino detector and for a multi-target dark matter experiment.

23 March 2026 in The European Physical Journal C
Verified
Journal Article
Open access
MFM. Folcarelli
M. Folcarelli
DDD. Delicato
D. Delicato
AAA. Acevedo-Rentería
A. Acevedo-Rentería
LAL. E. Ardila-Perez
L. E. Ardila-Perez
LBLaura Bandiera
Laura Bandiera
KZKangkang Zhao
Kangkang Zhao
BULLKID is a cryogenic, solid-state detector designed for direct searches of particle Dark Matter candidates, with mass $$\lesssim 1$$ ≲ 1 GeV/c $$^2$$ 2 , and coherent neutrino-nucleus scattering. It is based on an array of dice carved in 5 mm thick silicon crystal, sensed by phonon-mediated Kinetic Inductance Detectors. In previous works, the array was calibrated with bursts of optical photons, which are absorbed in the first hundreds nanometers of the dice and give rise to surface events. In this work, we present the reconstruction of bulk events through the 59.5 keV $$\gamma $$ γ -ray generated by an $$^{241}$$ 241 Am source, which emulates more closely the interaction of Dark Matter and neutrinos. The peak resolution is $$5\%~(\sigma )$$ 5 % ( σ ) and its position is shifted by less than $$10\%$$ 10 % with respect to the optical calibration. We observe that the resolution is further improved by a factor 2 combining the signal from neighboring dice. These results confirm the performance of the detector in view of the physics goals of the BULLKID-DM experiment for dark matter search.

20 April 2026 in Applied Physics Letters
Verified
Journal Article
Closed access
LPL. Pesce
L. Pesce
ASA. L. De Santis
A. L. De Santis
MCM. Calvo
M. Calvo
MCM. Cappelli
M. Cappelli
UCU. Chowdhury
U. Chowdhury
MVM. Vignati
M. Vignati
Cryogenic phonon detectors are adopted in light dark matter searches and coherent elastic neutrino-nucleus scattering experiments as they can achieve low energy thresholds. The phonon-mediated sensing of silicon particle absorbers has already been proved with kinetic inductance detectors (KIDs), acting both as sensors and athermal phonon absorbers. In this work, we present the design and the performance of an improved detector design. In this architecture, the KID acts only as a sensor and is coupled to dedicated phonon collectors. When a signal is coming from the substrate, the presence of a separated collector allows to detect a higher increase in quasi-particle density, thereby enhancing its responsivity. The meander of the KID is composed of a 77 nm trilayer wire of aluminum–titanium–aluminum, while the phonon collectors are made of a 100 nm aluminum layer and act as quasi-particle funnels. Inside the collectors, the absorbed athermal phonons generate quasi-particles, which, after diffusion, are trapped in the lower-gap superconducting trilayer. The performance of this setup is compared to that of a standard phonon-mediated KID, showing an increased phonon collection efficiency by a factor of around 7.

1 May 2026 in Journal of Instrumentation
Verified
Journal Article
Open access
LAL.E. Ardila-Perez
L.E. Ardila-Perez
TMT. Muscheid
T. Muscheid
RGR. Gartmann
R. Gartmann
DCD. Crovo
D. Crovo
ACA. Cruciani
A. Cruciani
MVM. Vignati
M. Vignati
We present the readout and data acquisition (DAQ) system for BULLKID-DM, a cryogenic dark-matter experiment employing Kinetic Inductance Detectors (KIDs) to probe below 1 GeV dark matter candidates. The system is built around an AMD RFSoC (ZCU216) platform that synthesizes densely spaced probe tones, performs frequency demultiplexing and amplitude demodulation, and executes real-time triggering and background suppression across up to 16 readout lines with 145 resonators per line in the 700 MHz to 950 MHz band. A fully automated calibration flow integrates vector-network-analyzer (VNA) functionality, resonator-circle acquisition with in-firmware phase rotation for maximum trigger sensitivity, and an energy calibration scheme based on LED illumination via a mezzanine board on the FMC+ connector. We summarize architecture, firmware, preliminary phase-noise studies, and the status of the detector demonstrator. The system is ready for scale-up to the full BULLKID-DM detector at the Laboratori Nazionali del Gran Sasso (LNGS).