G. Anda

G. Anda

Auto-generated profile, based on publicly available information

G. Anda

Wigner Research Centre for Physics, Budapest, Hungary

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SZS Zoletnik
S Zoletnik
GAG Anda
G Anda
MAM Aradi
M Aradi
OAO Asztalos
O Asztalos
SBS Bató
S Bató
MVM Vécsei
M Vécsei
Diagnosing the density profile at the edge of high temperature fusion plasmas by an accelerated lithium beam is a known technique since decades. By knowledge of the relevant atomic physics rate coefficients, the plasma electron density profile can be calculated from the relatively calibrated light profile along the beam. Several additional possibilities have already been demonstrated: Charge Exchange Resonance Spectroscopy (CXRS) for ion temperature/flow and Zeeman polarimetry for edge plasma current; therefore the Li-beam diagnostic offers a wealth of information at the plasma edge. The weaknesses of the method are the relatively faint light signal, background light, and technical difficulties of the beam injector which usually seriously limit the applicability. In this talk, we present systematic developments in alkali-beam diagnostics (Li, Na) for the injector and the observation system and detectors which resulted in strongly increased capabilities. Advanced systems have been built, and microsecond scale density profile, turbulence, and zonal flow measurement have been demonstrated. A novel edge current measurement technique has also been designed, and components have been tested with potential microsecond-scale time resolution. Additional possibilities of these advanced systems for spectral measurements (CXRS and various Zeeman schemes) are also discussed.

1 June 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SZS. Zoletnik
S. Zoletnik
GHG. H. Hu
G. H. Hu
BTB. Tál
B. Tál
DDD. Dunai
D. Dunai
GAG. Anda
G. Anda
TKT. Krizsanóczi
T. Krizsanóczi
A diagnostic instrument is described for the Experimental Advanced Superconducting Tokamak (EAST) for the measurement of the edge plasma electron density profile and plasma turbulence properties. An accelerated neutral lithium beam is injected into the tokamak and the Doppler shifted 670.8 nm light emission of the Li2p-2s transition is detected. A novel compact setup is used, where the beam injection and observation take place from the same equatorial diagnostic port and radial-poloidal resolution is achieved with microsecond time resolution. The observation direction is optimized in order to achieve a sufficient Doppler shift of the beam light to be able to separate from the strong edge lithium line emission on this lithium coated device. A 250 kHz beam chopping technique is also demonstrated for the removal of background light. First results show the capability of measuring turbulence and its poloidal flow velocity in the scrape-off layer and edge region and the resolution of details of transient phenomena like edge localized modes with few microsecond time resolution.

1 January 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
GAG. Anda
G. Anda
DDD. Dunai
D. Dunai
MLM. Lampert
M. Lampert
TKT. Krizsanóczi
T. Krizsanóczi
JNJ. Németh
J. Németh
SZS. Zoletnik
S. Zoletnik
A 60 keV neutral lithium beam system was designed and built up for beam emission spectroscopy measurement of edge plasma on the KSTAR and EAST tokamaks. The electron density profile and its fluctuation can be measured using the accelerated lithium beam-based emission spectroscopy system. A thermionic ion source was developed with a SiC heater to emit around 4-5 mA ion current from a 14 mm diameter surface. The ion optic is following the 2 step design used on other devices with small modifications to reach about 2-3 cm beam diameter in the plasma at about 4 m from the ion source. A newly developed recirculating sodium vapour neutralizer neutralizes the accelerated ion beam at around 260-280 °C even during long (<20 s) discharges. A set of new beam diagnostic and manipulation techniques are applied to allow optimization, aiming, cleaning, and beam modulation. The maximum 60 keV beam energy with 4 mA ion current was successfully reached at KSTAR and at EAST. Combined with an efficient observation system, the Li-beam diagnostic enables the measurement of the density profile and fluctuations on the plasma turbulence time scale.

1 August 2009 in Review of Scientific Instruments
Verified
Journal Article
Open access
IPI. Pusztai
I. Pusztai
GPG. Pokol
G. Pokol
DDD. Dunai
D. Dunai
DRD. Réfy
D. Réfy
GPG. Pór
G. Pór
JSJ. Schweinzer
J. Schweinzer
A deconvolution-based correction method of the beam emission spectroscopy (BES) density profile measurement is demonstrated by its application to simulated measurements of the COMPASS and TEXTOR tokamaks. If the line of sight is far from tangential to the flux surfaces, and the beam width is comparable to the scale length on which the light profile varies, the observation may cause an undesired smoothing of the light profile, resulting in a non-negligible underestimation of the calculated density profile. This effect can be reduced significantly by the emission reconstruction method, which gives an estimate of the emissivity along the beam axis from the measured light profile, taking the finite beam width and the properties of the measurement into account in terms of the transfer function of the observation. Characteristics and magnitude of the mentioned systematic error and its reduction by the introduced method are studied by means of the comprehensive alkali BES simulation code RENATE.

1 January 2024 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
JGJ. Galdon-Quiroga
J. Galdon-Quiroga
GBG. Birkenmeier
G. Birkenmeier
POP. Oyola
P. Oyola
HLH. Lindl
H. Lindl
ARA. Rodriguez-Gonzalez
A. Rodriguez-Gonzalez
ATAsdex Upgrade Team
Asdex Upgrade Team
The imaging heavy ion beam probe (i-HIBP) diagnostic has been successfully commissioned at ASDEX Upgrade. The i-HIBP injects a primary neutral beam into the plasma, where it is ionized, leading to a fan of secondary (charged) beams. These are deflected by the magnetic field of the tokamak and collected by a scintillator detector, generating a strike-line light pattern that encodes information on the density, electrostatic potential, and magnetic field of the plasma edge. The first measurements have been made, demonstrating the proof-of-principle of this diagnostic technique. A primary beam of 85/87Rb has been used with energies ranging between 60 and 72 keV and extracted currents up to 1.5 mA. The first signals have been obtained in experiments covering a wide range of parameter spaces, with plasma currents (Ip) between 0.2 and 0.8 MA and on-axis toroidal magnetic field (Bt) between 1.9 and 2.7 T. Low densities appear to be critical for the performance of the diagnostic, as signals are typically observed only when the line integrated density is below 2.0–3.0 × 1019 m−2 in the central interferometer chord, depending on the plasma shape. The strike line moves as expected when Ip is ramped, indicating that current measurements are possible. Additionally, clear dynamics in the intensity of the strike line are often observed, which might be linked to changes in the edge profile structure. However, the signal-to-background ratio of the signals is hampered by stray light, and the image guide degradation is due to neutron irradiation. Finally, simulations have been carried out to investigate the sensitivity of the expected signals to plasma density and temperature. The results are in qualitative agreement with the experimental observations, suggesting that the diagnostic is almost insensitive to fluctuations in the temperature profile, while the signal level is highly determined by the density profile due to the beam attenuation.

1 March 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
DRD. I. Réfy
D. I. Réfy
SZS. Zoletnik
S. Zoletnik
DDD. Dunai
D. Dunai
GAG. Anda
G. Anda
MLM. Lampert
M. Lampert
VWV. Weinzettl
V. Weinzettl
Atomic beam probe is an extension of the routinely used beam emission spectroscopy diagnostic for the plasma edge current fluctuation measurement at magnetically confined plasmas. Beam atoms ionized by the plasma are directed to a curved trajectory by the magnetic field and may be detected close to the wall of the device. The arrival location and current distribution of the ions carry information about the plasma current distribution, the density profile, and the electric potential in the plasma edge. This paper describes a micro-Faraday cup matrix detector for the measurement of the few microampere ion current distribution close to the plasma edge. The device implements a shallow Faraday cup matrix, produced by printed-circuit board technology. Secondary electrons induced by the plasma radiation and the ion bombardment are basically confined into the cups by the tokamak magnetic field. Additionally, a double mask is installed in the front face to limit the ion influx into the cups and supplement secondary electron suppression. The setup was tested in detail using a lithium ion beam in the laboratory. Switching time, cross talk, and fluctuation sensitivity test results in the lab setup are presented along with the detector setup to be installed at the COMPASS tokamak.