Mate Lampert

Mate Lampert

Auto-generated profile, based on publicly available information

Mate Lampert

Princeton Plasma Physics Laboratory

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 August 2024 in Nuclear Fusion
Verified
Journal Article
Open access
JBJ.W. Berkery
J.W. Berkery
PAP.O. Adebayo-Ige
P.O. Adebayo-Ige
HKH. Al Khawaldeh
H. Al Khawaldeh
GAG. Avdeeva
G. Avdeeva
SBS-G. Baek
S-G. Baek
SZS. Zweben
S. Zweben
The objectives of NSTX-U research are to reinforce the advantages of STs while addressing the challenges. To extend confinement physics of low-A, high beta plasmas to lower collisionality levels, understanding of the transport mechanisms that set confinement performance and pedestal profiles is being advanced through gyrokinetic simulations, reduced model development, and comparison to NSTX experiment, as well as improved simulation of RF heating. To develop stable non-inductive scenarios needed for steady-state operation, various performance-limiting modes of instability were studied, including MHD, tearing modes, and energetic particle instabilities. Predictive tools were developed, covering disruptions, runaway electrons, equilibrium reconstruction, and control tools. To develop power and particle handling techniques to optimize plasma exhaust in high performance scenarios, innovative lithium-based solutions are being developed to handle the very high heat flux levels that the increased heating power and compact geometry of NSTX-U will produce, and will be seen in future STs. Predictive capabilities accounting for plasma phenomena, like edge harmonic oscillations, ELMs, and blobs, are being tested and improved. In these ways, NSTX-U researchers are advancing the physics understanding of ST plasmas to maximize the benefit that will be gained from further NSTX-U experiments and to increase confidence in projections to future devices.

10 August 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
SZS Zoletnik
S Zoletnik
GAG Anda
G Anda
MAM Aradi
M Aradi
OAO Asztalos
O Asztalos
SBS Bató
S Bató
MVM Vécsei
M Vécsei
Diagnosing the density profile at the edge of high temperature fusion plasmas by an accelerated lithium beam is a known technique since decades. By knowledge of the relevant atomic physics rate coefficients, the plasma electron density profile can be calculated from the relatively calibrated light profile along the beam. Several additional possibilities have already been demonstrated: Charge Exchange Resonance Spectroscopy (CXRS) for ion temperature/flow and Zeeman polarimetry for edge plasma current; therefore the Li-beam diagnostic offers a wealth of information at the plasma edge. The weaknesses of the method are the relatively faint light signal, background light, and technical difficulties of the beam injector which usually seriously limit the applicability. In this talk, we present systematic developments in alkali-beam diagnostics (Li, Na) for the injector and the observation system and detectors which resulted in strongly increased capabilities. Advanced systems have been built, and microsecond scale density profile, turbulence, and zonal flow measurement have been demonstrated. A novel edge current measurement technique has also been designed, and components have been tested with potential microsecond-scale time resolution. Additional possibilities of these advanced systems for spectral measurements (CXRS and various Zeeman schemes) are also discussed.

1 July 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
MLM. Lampert
M. Lampert
GAG. Anda
G. Anda
ACA. Czopf
A. Czopf
EGErdei Gabor
Erdei Gabor
DGD. Guszejnov
D. Guszejnov
SZS. Zoletnik
S. Zoletnik
A novel beam emission spectroscopy observation system was designed, built, and installed onto the Korea Superconducting Tokamak Advanced Research tokamak. The system is designed in a way to be capable of measuring beam emission either from a heating deuterium or from a diagnostic lithium beam. The two beams have somewhat complementary capabilities: edge density profile and turbulence measurement with the lithium beam and two dimensional turbulence measurement with the heating beam. Two detectors can be used in parallel: a CMOS camera provides overview of the scene and lithium beam light intensity distribution at maximum few hundred Hz frame rate, while a 4 × 16 pixel avalanche photo-diode (APD) camera gives 500 kHz bandwidth data from a 4 cm × 16 cm region. The optics use direct imaging through lenses and mirrors from the observation window to the detectors, thus avoid the use of costly and inflexible fiber guides. Remotely controlled mechanisms allow adjustment of the APD camera’s measurement location on a shot-to-shot basis, while temperature stabilized filter holders provide selection of either the Doppler shifted deuterium alpha or lithium resonance line. The capabilities of the system are illustrated by measurements of basic plasma turbulence properties.

1 March 2024 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
JPJ. F. Parisi
J. F. Parisi
ANA. O. Nelson
A. O. Nelson
RGR. Gaur
R. Gaur
SKS. M. Kaye
S. M. Kaye
FPF. I. Parra
F. I. Parra
MMM. A. Miller
M. A. Miller
We use a new gyrokinetic threshold model to predict a bifurcation in tokamak pedestal width-height scalings that depends strongly on plasma shaping and aspect-ratio. The bifurcation arises from the first and second stability properties of kinetic-ballooning-modes that yields wide and narrow pedestal branches, expanding the space of accessible pedestal widths and heights. The wide branch offers potential for edge-localized-mode-free pedestals with high core pressure. For negative triangularity, low-aspect-ratio configurations are predicted to give steeper pedestals than conventional-aspect-ratio. Both wide and narrow branches have been attained in tokamak experiments.

1 November 2012 in Review of Scientific Instruments
Verified
Journal Article
Open access
DGD. Guszejnov
D. Guszejnov
GPG. I. Pokol
G. I. Pokol
IPI. Pusztai
I. Pusztai
DRD. Refy
D. Refy
SZS. Zoletnik
S. Zoletnik
YNY. U. Nam
Y. U. Nam
One of the main diagnostic tools for measuring electron density profiles and the characteristics of long wavelength turbulent wave structures in fusion plasmas is beam emission spectroscopy (BES). The increasing number of BES systems necessitated an accurate and comprehensive simulation of BES diagnostics, which in turn motivated the development of the Rate Equations for Neutral Alkali-beam TEchnique (RENATE) simulation code that is the topic of this paper. RENATE is a modular, fully three-dimensional code incorporating all key features of BES systems from the atomic physics to the observation, including an advanced modeling of the optics. Thus RENATE can be used both in the interpretation of measured signals and the development of new BES systems. The most important components of the code have been successfully benchmarked against other simulation codes. The primary results have been validated against experimental data from the KSTAR tokamak.

1 January 2018 in Review of Scientific Instruments
Verified
Journal Article
Closed access
GAG. Anda
G. Anda
DDD. Dunai
D. Dunai
MLM. Lampert
M. Lampert
TKT. Krizsanóczi
T. Krizsanóczi
JNJ. Németh
J. Németh
SZS. Zoletnik
S. Zoletnik
A 60 keV neutral lithium beam system was designed and built up for beam emission spectroscopy measurement of edge plasma on the KSTAR and EAST tokamaks. The electron density profile and its fluctuation can be measured using the accelerated lithium beam-based emission spectroscopy system. A thermionic ion source was developed with a SiC heater to emit around 4-5 mA ion current from a 14 mm diameter surface. The ion optic is following the 2 step design used on other devices with small modifications to reach about 2-3 cm beam diameter in the plasma at about 4 m from the ion source. A newly developed recirculating sodium vapour neutralizer neutralizes the accelerated ion beam at around 260-280 °C even during long (<20 s) discharges. A set of new beam diagnostic and manipulation techniques are applied to allow optimization, aiming, cleaning, and beam modulation. The maximum 60 keV beam energy with 4 mA ion current was successfully reached at KSTAR and at EAST. Combined with an efficient observation system, the Li-beam diagnostic enables the measurement of the density profile and fluctuations on the plasma turbulence time scale.