A. A. Ermak

A. A. Ermak

Auto-generated profile, based on publicly available information

A. A. Ermak

V.K. Gusak Institute of Emergency and Reconstructive Surgery of Minzdrav of Russia

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 August 2026 in Siberian Scientific Medical Journal
Verified
Journal Article
Open access
PDF file
Maksim SolopovMaksim Solopov
Maksim Solopov
APAndrey Popandopulo
Andrey Popandopulo
VTViktor Vasilevich Turchin
Viktor Vasilevich Turchin
AEA. A. Ermak
A. A. Ermak
SRS. A. Rudskoy
S. A. Rudskoy
РИР. В. Ищенко
Р. В. Ищенко
Accurate measurement of wound geometric parameters is essential for assessing injury severity and monitoring healing progress. Traditional manual methods have significant limitations: high error rates, subjectivity, and risk of infection. Modern digital techniques lack these drawbacks but are often expensive and complex. This study presents an alternative solution: an automated scanning platform assembled from affordable components.    Aim of the study  was to develop and validate a robotic XY-scanning platform for automated 3D analysis of ex vivo models of superficial skin wounds and to evaluate its accuracy compared to standard manual measurement methods.    Material and methods.  The hardware of the platform was developed using an Arduino Uno microcontroller, 28BYJ-48 stepper motors, and a Sharp 2Y0A21 infrared distance sensor. The software controls the scanning process and calculates wound parameters: volume (using Simpson’s method), area (using the Gaussian formula), and maximum depth. For validation, six model wounds with varying geometries were created on porcine skin samples. Their parameters were independently measured by the automated system and manual methods: volume by filling with saline solution, depth with a caliper, and area by planimetry in ImageJ software.    Results.  Statistical analysis demonstrated high agreement between automated and manual measurements. The highest accuracy was achieved in volume assessment: the mean difference between methods (0.37 cm 3 , p = 0.156), Spearman’s (ρ = 1.00) and Lin’s concordance correlation coefficient (> 0.98) indicated nearly perfect concordance. Depth measurements also showed high reliability, despite a minor systematic underestimation by the automated system averaging 0.99 mm (p = 0.094). A strong monotonic relationship was confirmed (ρ = 0.94). For wound area, a statistically significant systematic bias was identified: the platform consistently overestimated values by an average of 1.98 cm 2 (p = 0.031), likely due to hardware limitations and insufficient system resolution.    Conclusions.  The developed platform proved effective for automated, non-contact measurement of wound volume and depth, combining component affordability and automation. The main limitation is a systematic error in area measurement. Future work involves hardware modernization (installing a high-precision laser sensor) and further validation on an expanded sample of various wound types for implementation in clinical and research practice.