This paper presents simulation results for a taxonomy of typical distribution feeders with various levels of photovoltaic (PV) penetration. For each of the 16 feeders simulated, the maximum PV penetration that did not result in a steady-state voltage or current violation is presented for several PV location scenarios: clustered near the feeder source, clustered near the midpoint of the feeder, clustered near the end of the feeder, randomly located, and evenly distributed. In addition, the maximum level of PV is presented for single, large PV systems at each location. Maximum PV penetration was determined by requiring that feeder voltages stay within ANSI Range A and that feeder currents stay within the ranges determined by overcurrent protection devices. Generation ramp rates, protection and coordination, and other factors that may impact maximum PV penetrations are not considered here. Simulations were run in GridLAB-D using hourly time steps over a year with randomized load profiles based on utility data and typical meteorological year weather data. For 86% of the 336 cases simulated, maximum PV penetration was at least 30% of peak load.
18 August 2021 in IEEE Transactions on Sustainable Energy
Non-utility owned distributed energy resources (DERs) are mostly untapped currently, but they can provide many grid services such as voltage regulation and service restoration, if properly controlled, and can improve the distribution system's reliability when coordinated with utility-owned assets such as self-healing control and microgrids. This paper integrates transactive energy control into the distribution system reliability evaluation to quantitatively assess the impact of non-utility owned DERs on reliability improvement. A transactive reactive power control strategy is designed to incentivize the DERs to provide reactive power support for improving voltage profiles thus enabling additional customer load restoration during an outage. Also, an operational sequence to coordinate the non-utility owned DERs with the utility owned self-healing control and utility owned microgrids is designed and integrated into the service restoration process with the operational constraints guaranteed by checking the three-phase unbalanced power flow for post-fault network reconfiguration. The reliability indices are then calculated through a Monte Carlo simulation. The transactive reactive power control strategy is tested on a four-feeder distribution system operated by Duke Energy in the U.S. Results demonstrate that the non-utility owned DERs with the transactive control improve the reliability of both the system and critical loads by more than 30%.
This paper describes a granular approach for investigating the impacts of very high PV generation penetration. Studies on two real-world distribution feeders connected to PV plants are presented. The studies include both steady-state and time series power flow analyses, which include the effects of solar variability. The goal of the study is to predict the effects of increasing levels of PV generation as it reaches very high penetration levels. Impact results from the analyses are described along with potential mitigations.
18 October 2010 in IEEE Transactions on Power Systems
Grid modernization strategies often focus on replacing aging distribution control equipment with state-of-the-art devices capable of remote monitoring, communication, and control. However, wholesale replacement of the existing distribution infrastructure may not be practical or economical. Additionally, even with improved capabilities, “smart” devices may still be ignorant of changes in circuit topology. This paper presents a model-based distribution control scheme that is independent of circuit topology and integrates legacy and modern control equipment. Simulation results indicate the proposed method can improve circuit performance under both normal and abnormal conditions.
This study considers potential system effects from the addition of Plug-in Electric Vehicle (PEV) load to individually metered residential customers together with a concurrent market adoption of Distributed Energy Resources (DER) and energy storage technologies to offset the associated load growth. To evaluate various renewable energy source conditions, a prototypical circuit is evaluated in Detroit, Los Angeles, and Orlando locations for both summer and winter loading conditions. Various load adoption scenarios are simulated by randomly assigning specified loading to target customer classes on the circuit.