Marcus Allen

Marcus Allen

Auto-generated profile, based on publicly available information

Marcus Allen

Department of Mechanical Engineering and Materials Science, Swanson School of Engineering, University of Pittsburgh, Pittsburgh, PA 15260, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
KBKevin Bell
Kevin Bell
COChukwudi Onyeukwu
Chukwudi Onyeukwu
MMMichael P. McClincy
Michael P. McClincy
MAMarcus Allen
Marcus Allen
LBLaura Bechard
Laura Bechard
JIJames J. Irrgang
James J. Irrgang
Rehabilitation following knee injury or surgery is critical for recovery of function and independence. However, patient non-adherence remains a significant barrier to success. Remote rehabilitation using mobile health (mHealth) technologies have potential for improving adherence to and execution of home exercise. We developed a remote rehabilitation management system combining two wireless inertial measurement units (IMUs) with an interactive mobile application and a web-based clinician portal (interACTION). However, in order to translate interACTION into the clinical setting, it was first necessary to verify the efficacy of measuring knee motion during rehabilitation exercises for physical therapy and determine if visual feedback significantly improves the participant’s ability to perform the exercises correctly. Therefore, the aim of this study was to verify the accuracy of the IMU-based knee angle measurement system during three common physical therapy exercises, quantify the effect of visual feedback on exercise performance, and understand the qualitative experience of the user interface through survey data. A convenience sample of ten healthy control participants were recruited for an IRB-approved protocol. Using the interACTION application in a controlled laboratory environment, participants performed ten repetitions of three knee rehabilitation exercises: heel slides, short arc quadriceps contractions, and sit-to-stand. The heel slide exercise was completed without feedback from the mobile application, then all exercises were performed with visual feedback. Exercises were recorded simultaneously by the IMU motion tracking sensors and a video-based motion tracking system. Validation showed moderate to good agreement between the two systems for all exercises and accuracy was within three degrees. Based on custom usability survey results, interACTION was well received. Overall, this study demonstrated the potential of interACTION to measure range of motion during rehabilitation exercises for physical therapy and visual feedback significantly improved the participant’s ability to perform the exercises correctly.

7 September 2017 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
MAMarcus Allen
Marcus Allen
QZQiang Zhong
Qiang Zhong
NKNicholas Kirsch
Nicholas Kirsch
ADAshwin Dani
Ashwin Dani
WCWilliam W Clark
William W Clark
NSNitin Sharma
Nitin Sharma
Miniature inertial measurement units (IMUs) are wearable sensors that measure limb segment or joint angles during dynamic movements. However, IMUs are generally prone to drift, external magnetic interference, and measurement noise. This paper presents a new class of nonlinear state estimation technique called state-dependent coefficient (SDC) estimation to accurately predict joint angles from IMU measurements. The SDC estimation method uses limb dynamics, instead of limb kinematics, to estimate the limb state. Importantly, the nonlinear limb dynamic model is formulated into state-dependent matrices that facilitate the estimator design without performing a Jacobian linearization. The estimation method is experimentally demonstrated to predict knee joint angle measurements during functional electrical stimulation of the quadriceps muscle. The nonlinear knee musculoskeletal model was identified through a series of experiments. The SDC estimator was then compared with an extended kalman filter (EKF), which uses a Jacobian linearization and a rotation matrix method, which uses a kinematic model instead of the dynamic model. Each estimator's performance was evaluated against the true value of the joint angle, which was measured through a rotary encoder. The experimental results showed that the SDC estimator, the rotation matrix method, and EKF had root mean square errors of 2.70°, 2.86°, and 4.42°, respectively. Our preliminary experimental results show the new estimator's advantage over the EKF method but a slight advantage over the rotation matrix method. However, the information from the dynamic model allows the SDC method to use only one IMU to measure the knee angle compared with the rotation matrix method that uses two IMUs to estimate the angle.

3 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
ARAhmad Al Rashdan
Ahmad Al Rashdan
HAHany Abdel-Khalik
Hany Abdel-Khalik
KGKellen M. Giraud
Kellen M. Giraud
DCDaniel G. Cole
Daniel G. Cole
JFJacob Farber
Jacob Farber
AVAthi Varuttamaseni
Athi Varuttamaseni
To facilitate the automated online monitoring of power plants, a systematic and qualitative strategy for anomaly detection is presented. This strategy is essential to provide credible reasoning on why and when an empirical versus hybrid (i.e., physics-supported) approach should be used and to determine the ideal mix of these two approaches for a defined anomaly detection scope. Empirical methods are usually based on pattern, statistical, and causal inference. Hybrid methods include the use of physics models to train and test data methods, reduce data dimensionality, reduce data-model complexity, augment data, and reduce empirical uncertainty; hybrid methods also include the use of data to tune physics models. The presented strategy is driven by key decision points related to data relevance, simple modeling feasibility, data inference, physics-modeling value, data dimensionality, physics knowledge, method of validation, performance, data availability, and suitability for training and testing, cause-effect, entropy inference, and model fitting. The strategy is demonstrated through a pilot use case for the application of anomaly detection to capture a valve packing leak at the high-pressure coolant injection system of a nuclear power plant.