William W Clark

Prof. Dr. William W Clark

orcid

Research Focus & Metrics

Academic Career Length

35Years (1992-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 October 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ABAnna Bailes
Anna Bailes
MJMarit E Johnson
Marit E Johnson
RRRachel Roos
Rachel Roos
WCWilliam W Clark
William W Clark
HCHarold Allen Cook
Harold Allen Cook
KBKevin Bell
Kevin Bell
Inertial measurement units (IMUs) provide benefits over the traditional optoelectronic motion capture (OMC) systems in measuring kinematics for the low back pain population. The reliability and validity of IMUs to quantify three-dimensional motion for multiple hip/spine segments have not been systematically evaluated. The purpose of this study was to determine the repeated-measures reliability and concurrent validity of an IMU system for measuring the three-dimensional spine/hip kinematics in six common movement assessments. Seventeen participants (32.3 (14.7) years; 11 female) performed two trials each of six range-of-motion assessments while fitted with four IMUs (T1/T2, T12/L1, L5/S1, and femur). The IMUs showed good–excellent reliability for most of the movements in the primary plane and poor–moderate reliability in the non-primary planes. The IMU and OMC systems showed generally good–excellent agreement in the primary plane and RMSE values between 3.03° and 15.75°. The removal of outliers based on the Bland–Altman analysis resulted in RMSE values between 2.44° and 10.30°. The system agreement in the non-primary planes was generally poor–moderate, and the RMSE values ranged from 2.19° to 45.88°. Anomalies in the proprietary sensor fusion algorithm or calibration may have contributed to the large RMSE values, highlighting the importance of assessing data for physiological relevance. The results suggest that these IMUs may be best suited for population-based studies measuring movement in the primary plane and point toward the need for the development of more robust approaches for broader implementation.

15 June 1993 in Optics Letters
Verified
Journal Article
Closed access
PDF file
RARichard J. Anderson
Richard J. Anderson
ESEdward J. Sharp
Edward J. Sharp
GSGregory J. Salamo
Gregory J. Salamo
RNRatnakar R. Neurgaonkar
Ratnakar R. Neurgaonkar
GWGary L. Wood
Gary L. Wood
QVQuochien Vuong
Quochien Vuong
Cross talk is observed in a photorefractive bridge mutually pumped phase conjugator during the transient time of photorefractive grating formation and is utilized to construct a moving-object correlator. The correlation of various input images has been demonstrated and compared with calculated results. The device is currently capable of a resolution of approximately 4 to 6 lines/mm.

7 September 2017 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
MAMarcus Allen
Marcus Allen
QZQiang Zhong
Qiang Zhong
NKNicholas Kirsch
Nicholas Kirsch
ADAshwin Dani
Ashwin Dani
WCWilliam W Clark
William W Clark
NSNitin Sharma
Nitin Sharma
Miniature inertial measurement units (IMUs) are wearable sensors that measure limb segment or joint angles during dynamic movements. However, IMUs are generally prone to drift, external magnetic interference, and measurement noise. This paper presents a new class of nonlinear state estimation technique called state-dependent coefficient (SDC) estimation to accurately predict joint angles from IMU measurements. The SDC estimation method uses limb dynamics, instead of limb kinematics, to estimate the limb state. Importantly, the nonlinear limb dynamic model is formulated into state-dependent matrices that facilitate the estimator design without performing a Jacobian linearization. The estimation method is experimentally demonstrated to predict knee joint angle measurements during functional electrical stimulation of the quadriceps muscle. The nonlinear knee musculoskeletal model was identified through a series of experiments. The SDC estimator was then compared with an extended kalman filter (EKF), which uses a Jacobian linearization and a rotation matrix method, which uses a kinematic model instead of the dynamic model. Each estimator's performance was evaluated against the true value of the joint angle, which was measured through a rotary encoder. The experimental results showed that the SDC estimator, the rotation matrix method, and EKF had root mean square errors of 2.70°, 2.86°, and 4.42°, respectively. Our preliminary experimental results show the new estimator's advantage over the EKF method but a slight advantage over the rotation matrix method. However, the information from the dynamic model allows the SDC method to use only one IMU to measure the knee angle compared with the rotation matrix method that uses two IMUs to estimate the angle.

27 November 2008
Verified
Book Chapter
Closed access
PDF file
WCWilliam W Clark
William W Clark
CMChangki Mo
Changki Mo

19 May 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YZYifan Zhang
Yifan Zhang
WCWilliam W Clark
William W Clark
BTBryan Tillman
Bryan Tillman
YCYoungjae Chun
Youngjae Chun
SLStephanie Liu
Stephanie Liu
Sung Kwon ChoSung Kwon Cho
Sung Kwon Cho
This paper will introduce a simple locating system to track a stent when it is deployed into a human artery. The stent is proposed to achieve hemostasis for bleeding soldiers on the battlefield, where common surgical imaging equipment such as fluoroscopy systems are not available. In the application of interest, the stent must be guided to the right location to avoid serious complications. The most important features are its relative accuracy and the ease by which it may be quickly set up and used in a trauma situation. The locating approach in this paper utilizes a magnet outside the human body as the reference and a magnetometer that will be deployed inside the artery with the stent. The sensor can detect its location in a coordinate system centered with the reference magnet. In practice, the main challenge is that the locating accuracy will be deteriorated by external magnetic interference, rotation of the sensor, and random noise. These causes of error are addressed in the paper to improve the locating accuracy and repeatability under various conditions. Finally, the system’s locating performance will be validated in benchtop experiments, where the effects of the disturbance-eliminating procedures will be addressed.

3 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
ARAhmad Al Rashdan
Ahmad Al Rashdan
HAHany Abdel-Khalik
Hany Abdel-Khalik
KGKellen M. Giraud
Kellen M. Giraud
DCDaniel G. Cole
Daniel G. Cole
JFJacob Farber
Jacob Farber
AVAthi Varuttamaseni
Athi Varuttamaseni
To facilitate the automated online monitoring of power plants, a systematic and qualitative strategy for anomaly detection is presented. This strategy is essential to provide credible reasoning on why and when an empirical versus hybrid (i.e., physics-supported) approach should be used and to determine the ideal mix of these two approaches for a defined anomaly detection scope. Empirical methods are usually based on pattern, statistical, and causal inference. Hybrid methods include the use of physics models to train and test data methods, reduce data dimensionality, reduce data-model complexity, augment data, and reduce empirical uncertainty; hybrid methods also include the use of data to tune physics models. The presented strategy is driven by key decision points related to data relevance, simple modeling feasibility, data inference, physics-modeling value, data dimensionality, physics knowledge, method of validation, performance, data availability, and suitability for training and testing, cause-effect, entropy inference, and model fitting. The strategy is demonstrated through a pilot use case for the application of anomaly detection to capture a valve packing leak at the high-pressure coolant injection system of a nuclear power plant.