Mehran Armand

Mehran Armand

Auto-generated profile, based on publicly available information

Mehran Armand

Department of Computer Science, Johns Hopkins University, Baltimore, MD, USA

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 November 2011 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
YOYoshito Otake
Yoshito Otake
MAMehran Armand
Mehran Armand
RARobert Armiger
Robert Armiger
MKMichael D. Kutzer
Michael D. Kutzer
EBEhsan Basafa
Ehsan Basafa
RTRussell H. Taylor
Russell H. Taylor
Intraoperative patient registration may significantly affect the outcome of image-guided surgery (IGS). Image-based registration approaches have several advantages over the currently dominant point-based direct contact methods and are used in some industry solutions in image-guided radiation therapy with fixed X-ray gantries. However, technical challenges including geometric calibration and computational cost have precluded their use with mobile C-arms for IGS. We propose a 2D/3D registration framework for intraoperative patient registration using a conventional mobile X-ray imager combining fiducial-based C-arm tracking and graphics processing unit (GPU)-acceleration. The two-stage framework 1) acquires X-ray images and estimates relative pose between the images using a custom-made in-image fiducial, and 2) estimates the patient pose using intensity-based 2D/3D registration. Experimental validations using a publicly available gold standard dataset, a plastic bone phantom and cadaveric specimens have been conducted. The mean target registration error (mTRE) was 0.34±0.04 mm (success rate: 100%, registration time: 14.2 s) for the phantom with two images 90° apart, and 0.99±0.41 mm (81%, 16.3 s) for the cadaveric specimen with images 58.5° apart. The experimental results showed the feasibility of the proposed registration framework as a practical alternative for IGS routines.

22 September 2016 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
AGAnzhu Gao
Anzhu Gao
RMRyan J. Murphy
Ryan J. Murphy
HLHao Liu
Hao Liu
IULIAN IORDACHITAIULIAN IORDACHITA
IULIAN IORDACHITA
MAMehran Armand
Mehran Armand
Dexterous continuum manipulators (DCMs) have been widely adopted for minimally- and less-invasive surgery. During the operation, these DCMs interact with surrounding anatomy actively or passively. The interaction force will inevitably affect the tip position and shape of DCMs, leading to potentially inaccurate control near critical anatomy. In this paper, we demonstrated a two-dimensional mechanical model for a tendon actuated, notched DCM with compliant joints. The model predicted deformation of the DCM accurately in the presence of tendon force, friction force, and external force. A partition approach was proposed to describe the DCM as a series of interconnected rigid and flexible links. Beam mechanics, taking into consideration tendon interaction and external force on the tip and the body, was applied to obtain the deformation of each flexible link of the DCM. The model results were compared with experiments for free bending as well as bending in the presence of external forces acting at either the tip or body of the DCM. The overall mean error of tip position between model predictions and all of the experimental results was 0.62 ± 0.41 mm. The results suggest that the proposed model can effectively predict the shape of the DCM.

19 January 2023 in IEEE Transactions on Visualization and Computer Graphics
Verified
Journal Article
Open access
AMAlejandro Martin-Gomez
Alejandro Martin-Gomez
HLHaowei Li
Haowei Li
TSTianyu Song
Tianyu Song
SYSheng Yang
Sheng Yang
GWGuangzhi Wang
Guangzhi Wang
MAMehran Armand
Mehran Armand
The use of Augmented Reality (AR) for navigation purposes has shown beneficial in assisting physicians during the performance of surgical procedures. These applications commonly require knowing the pose of surgical tools and patients to provide visual information that surgeons can use during the performance of the task. Existing medical-grade tracking systems use infrared cameras placed inside the Operating Room (OR) to identify retro-reflective markers attached to objects of interest and compute their pose. Some commercially available AR Head-Mounted Displays (HMDs) use similar cameras for self-localization, hand tracking, and estimating the objects' depth. This work presents a framework that uses the built-in cameras of AR HMDs to enable accurate tracking of retro-reflective markers without the need to integrate any additional electronics into the HMD. The proposed framework can simultaneously track multiple tools without having previous knowledge of their geometry and only requires establishing a local network between the headset and a workstation. Our results show that the tracking and detection of the markers can be achieved with an accuracy of $0.09\pm 0.06\ mm$ on lateral translation, $0.42 \pm 0.32\ mm$ on longitudinal translation and $0.80 \pm 0.39^\circ$ for rotations around the vertical axis. Furthermore, to showcase the relevance of the proposed framework, we evaluate the system's performance in the context of surgical procedures. This use case was designed to replicate the scenarios of k-wire insertions in orthopedic procedures. For evaluation, seven surgeons were provided with visual navigation and asked to perform 24 injections using the proposed framework. A second study with ten participants served to investigate the capabilities of the framework in the context of more general scenarios. Results from these studies provided comparable accuracy to those reported in the literature for AR-based navigation procedures.

5 June 2015 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HLHao Liu
Hao Liu
AFAmirhossein Farvardin
Amirhossein Farvardin
RGRobert Grupp
Robert Grupp
RMRyan J. Murphy
Ryan J. Murphy
RTRussell H. Taylor
Russell H. Taylor
MAMehran Armand
Mehran Armand
Dexterous continuum manipulators (DCMs) can largely increase the reachable region and steerability for minimally and less invasive surgery. Many such procedures require the DCM to be capable of producing large deflections. The real-time control of the DCM shape requires sensors that accurately detect and report large deflections. We propose a novel, large deflection, shape sensor to track the shape of a 35 mm DCM designed for a less invasive treatment of osteolysis. Two shape sensors, each with three fiber Bragg grating sensing nodes is embedded within the DCM, and the sensors' distal ends fixed to the DCM. The DCM centerline is computed using the centerlines of each sensor curve. An experimental platform was built and different groups of experiments were carried out, including free bending and three cases of bending with obstacles. For each experiment, the DCM drive cable was pulled with a precise linear slide stage, the DCM centerline was calculated, and a 2D camera image was captured for verification. The reconstructed shape created with the shape sensors is compared with the ground truth generated by executing a 2D-3D registration between the camera image and 3D DCM model. Results show that the distal tip tracking accuracy is 0.40 ± 0.30 mm for the free bending and 0.61 ± 0.15 mm, 0.93 ± 0.05 mm and 0.23 ± 0.10 mm for three cases of bending with obstacles. The data suggest FBG arrays can accurately characterize the shape of large-deflection DCMs.

1 January 2009 in Acta Orthopaedica
Verified
Journal Article
Open access
RARobert S Armiger
Robert S Armiger
MAMehran Armand
Mehran Armand
KTKaj Tallroth
Kaj Tallroth
JLJyri Lepistö
Jyri Lepistö
SMSimon C Mears
Simon C Mears
Because of the varying structure of dysplastic hips, the optimal realignment of the joint during periacetabular osteotomy (PAO) may differ between patients. Three-dimensional (3D) mechanical and radiological analysis possibly accounts better for patient-specific morphology, and may improve and automate optimal joint realignment. We evaluated the 10-year outcomes of 12 patients following PAO. We compared 3D mechanical analysis results to both radiological and clinical measurements. A 3D discrete-element analysis algorithm was used to calculate the pre- and postoperative contact pressure profile within the hip. Radiological angles describing the coverage of the joint were measured using a computerized approach at actual and theoretical orientations of the acetabular cup. Quantitative results were compared using postoperative clinical evaluation scores (Harris score), and patient-completed outcome surveys (q-score) done at 2 and 10 years. The 3D mechanical analysis indicated that peak joint contact pressure was reduced by an average factor of 1.7 subsequent to PAO. Lateral coverage of the femoral head increased in all patients; however, it did not proportionally reduce the maximum contact pressure and, in 1 case, the pressure increased. This patient had the lowest 10-year q-score (70 out of 100) of the cohort. Another hip was converted to hip arthroplasty after 3 years because of increasing osteoarthritis. The 3D analysis showed that a reduction in contact pressure was theoretically possible for all patients in this cohort, but this could not be achieved in every case during surgery. While intraoperative factors may affect the actual surgical outcome, the results show that 3D contact pressure analysis is consistent with traditional PAO planning techniques (more so than 2D analysis) and may be a valuable addition to preoperative planning and intraoperative assessment of joint realignment.

20 December 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
FAFarshid Alambeigi
Farshid Alambeigi
ZWZerui Wang
Zerui Wang
RHRachel Hegeman
Rachel Hegeman
YLYunhui Liu
Yunhui Liu
MAMehran Armand
Mehran Armand
We present an autonomous manipulation approach for tissues with anisotropic deformation behavior using a continuum manipulator. The key feature of our visionbased study is an online learning and estimation method, which makes its implementation independent of any prior knowledge about (i) the deformation behavior of the tissue and (ii) continuum manipulator as well as (iii) calibration of the vision system with respect to the robot. This important feature addresses the difficulty of using model-based control approaches in deformation control of a continuum manipulator manipulating an unknown deformable tissue. We evaluated the performance and robustness of our method in three different experiments using the da Vinci Research Kit coupled with a 5 mm instrument that has a 4-degree-of-freedom snake-like wrist. These experiments simulated situations that occur in various surgical schemes and verified the adaptability, learning capability, and accuracy of the proposed method.